Buffer composition suitable for determining very low fluoride concentrations using a fluoride ion-selective electrode and its application to the continuous analysis of rain water

被引:32
作者
Hara, H
Huang, CC
机构
[1] Department of Chemistry, Faculty of Education, Shiga University, Otsu
关键词
rain water analysis; ion-selective electrodes; acidic buffer; continuous monitoring; flow analysis;
D O I
10.1016/S0003-2670(96)00432-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In order to continuously analyze rain water with a fluoride ion-selective electrode (F- ISE), various buffer systems were examined in terms of the sensitivity enhancement. On the basis of the result that the sensitivity could be maximized at around pH 2.8 using the conventional acetate buffer, we proposed Sorensen's buffer (a mixture of glycine and hydrochloric acid, pH 2.8) to be most suitable for rain water analysis. The limit of linear response was 1x10(-7) mol dm(-3) and the detection limit was 1x10(-8) mol dm(-3) by optimizing the sample to buffer dilution rate as 10:1. A good correlation was found between the results from the rain water analysis using this method and those of ion chromatography. A continuous analysis of rain water during a rainfall event was successfully carried out.
引用
收藏
页码:141 / 147
页数:7
相关论文
共 26 条
[1]   FLUORIDE IN PRECIPITATION .1. METHODOLOGY WITH THE FLUORIDE-SELECTIVE ELECTRODE [J].
BARNARD, WR ;
NORDSTROM, DK .
ATMOSPHERIC ENVIRONMENT, 1982, 16 (01) :99-103
[2]   SENSITIVITY OF FLUORIDE-SELECTIVE ELECTRODE BELOW MICROMOLAR RANGE [J].
BAUMANN, EW .
ANALYTICA CHIMICA ACTA, 1971, 54 (02) :189-&
[3]   BUFFER SYSTEMS FOR USE WITH THE FLUORIDE ELECTRODE IN FLOW-INJECTION ANALYSIS [J].
CARDWELL, TJ ;
CATTRALL, RW ;
HAUSER, PC ;
HAMILTON, IC .
ANALYTICAL CHEMISTRY, 1987, 59 (01) :206-208
[4]  
DENG M, 1984, CHINESE J ANAL CHEM, V12, P946
[5]   ELECTRODE FOR SENSING FLUORIDE ION ACTIVITY IN SOLUTION [J].
FRANT, MS ;
ROSS, JW .
SCIENCE, 1966, 154 (3756) :1553-&
[6]  
FUCKO J, 1987, ANAL CHIM ACTA, V194, P163
[7]   INTERFERENCE STUDY ON A CONTINUOUS-FLOW DETERMINATION SYSTEM FOR SULFATE WITH A LEAD-SELECTIVE ELECTRODE DETECTOR AND ITS APPLICATION TO NATURAL-WATER ANALYSIS [J].
HARA, H ;
MORI, S .
ANALYST, 1990, 115 (08) :1077-1083
[8]   CONTINUOUS-FLOW DETERMINATION OF CHLORIDE IN THE NONLINEAR RESPONSE REGION WITH A TUBULAR CHLORIDE ION-SELECTIVE ELECTRODE [J].
HARA, H ;
WAKIZAKA, Y ;
OKAZAKI, S .
TALANTA, 1987, 34 (11) :921-926
[10]   CONTINUOUS-FLOW REAL-TIME AND FLOW-INJECTION DETERMINATION OF RAINWATER PH WITH A POLYVINYL CHLORIDE-BASED TUBULAR MEMBRANE-ELECTRODE [J].
MADSEN, BC ;
DOLLER, DW .
ANALYTICAL CHEMISTRY, 1987, 59 (01) :127-130