The video head impulse test Diagnostic accuracy in peripheral vestibulopathy

被引:643
作者
MacDougall, H. G. [2 ]
Weber, K. P. [1 ]
McGarvie, L. A. [1 ]
Halmagyi, G. M. [1 ]
Curthoys, I. S. [2 ]
机构
[1] Royal Prince Alfred Hosp, Dept Neurol, Camperdown, NSW 2050, Australia
[2] Univ Sydney, Sch Psychol, Vestibular Res Lab, Sydney, NSW 2006, Australia
基金
澳大利亚研究理事会; 美国国家航空航天局; 英国医学研究理事会;
关键词
3-DIMENSIONAL VECTOR ANALYSIS; HUMAN VESTIBULOOCULAR REFLEX; SEMICIRCULAR-CANAL FUNCTION; SEARCH-COIL; NEURITIS; ROTATIONS; OCULOGRAPHY; RESPONSES; STARD;
D O I
10.1212/WNL.0b013e3181bacf85
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: The head impulse test (HIT) is a useful bedside test to identify peripheral vestibular deficits. However, such a deficit of the vestibulo-ocular reflex (VOR) may not be diagnosed because corrective saccades cannot always be detected by simple observation. The scleral search coil technique is the gold standard for HIT measurements, but it is not practical for routine testing or for acute patients, because they are required to wear an uncomfortable contact lens. Objective: To develop an easy-to-use video HIT system (vHIT) as a clinical tool for identifying peripheral vestibular deficits. To validate the diagnostic accuracy of vHIT by simultaneous measures with video and search coil recordings across healthy subjects and patients with a wide range of previously identified peripheral vestibular deficits. Methods: Horizontal HIT was recorded simultaneously with vHIT (250 Hz) and search coils (1,000 Hz) in 8 normal subjects, 6 patients with vestibular neuritis, 1 patient after unilateral intratympanic gentamicin, and 1 patient with bilateral gentamicin vestibulotoxicity. Results: Simultaneous video and search coil recordings of eye movements were closely comparable (average concordance correlation coefficient r(c) = 0.930). Mean VOR gains measured with search coils and video were not significantly different in normal (p = 0.107) and patients (p = 0.073). With these groups, the sensitivity and specificity of both the reference and index test were 1.0 (95% confidence interval 0.69-1.0). vHIT measures detected both overt and covert saccades as accurately as coils. Conclusions: The video head impulse test is equivalent to search coils in identifying peripheral vestibular deficits but easier to use in clinics, even in patients with acute vestibular neuritis. Neurology (R) 2009; 73: 1134-1141
引用
收藏
页码:1134 / 1141
页数:8
相关论文
共 23 条
[1]   Three-dimensional vector analysis of the human vestibuloocular reflex in response to high-acceleration head rotations .2. Responses in subjects with unilateral vestibular loss and selective semicircular canal occlusion [J].
Aw, ST ;
Halmagyi, GM ;
Haslwanter, T ;
Curthoys, IS ;
Yavor, RA ;
Todd, MJ .
JOURNAL OF NEUROPHYSIOLOGY, 1996, 76 (06) :4021-4030
[2]   Three-dimensional vector analysis of the human vestibuloocular reflex in response to high-acceleration head rotations .1. Responses in normal subjects [J].
Aw, ST ;
Haslwanter, T ;
Halmagyi, GM ;
Curthoys, IS ;
Yavor, RA ;
Todd, MJ .
JOURNAL OF NEUROPHYSIOLOGY, 1996, 76 (06) :4009-4020
[3]   Individual semicircular canal function in superior and inferior vestibular neuritis [J].
Aw, ST ;
Fetter, M ;
Cremer, PD ;
Karlberg, M ;
Halmagyi, GM .
NEUROLOGY, 2001, 57 (05) :768-774
[4]   Head Impulse Testing Using Video-oculography [J].
Bartl, Klaus ;
Lehnen, Nadine ;
Kohlbecher, Stefan ;
Schneider, Erich .
BASIC AND CLINICAL ASPECTS OF VERTIGO AND DIZZINESS, 2009, 1164 :331-333
[5]   The active head-impulsc test in unilateral peripheral vestibulopathy [J].
Black, RA ;
Halmagyi, GM ;
Thurtell, MJ ;
Todd, MJ ;
Curthoys, IS .
ARCHIVES OF NEUROLOGY, 2005, 62 (02) :290-293
[6]   Towards complete and,accurate reporting of studies of diagnostic accuracy: the STARD initiative [J].
Bossuyt, PM ;
Reitsma, JB ;
Bruns, DE ;
Gatsonis, CA ;
Glasziou, PP ;
Irwig, LM ;
Lijmer, JG ;
Moher, D ;
Rennie, D ;
de Vet, HCE .
BRITISH MEDICAL JOURNAL, 2003, 326 (7379) :41-44
[7]  
BRANDT T, 1999, VERTIGO ITS MULTISEN, P67
[8]   Bedside differentiation of vestibular neuritis from central "vestibular pseudoneuritis'' [J].
Cnyrim, C. D. ;
Newman-Toker, D. ;
Karch, C. ;
Brandt, T. ;
Strupp, Michael .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2008, 79 (04) :458-460
[9]   Maximum permissible exposures for ocular safety (ANSI 2000), with emphasis on ophthalmic devices [J].
Delori, Francois C. ;
Webb, Robert H. ;
Sliney, David H. .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2007, 24 (05) :1250-1265
[10]  
HABBEMA JDF, 2008, EVIDENCE BASE CLIN D, P118