Retention and wear behaviors of two implant overdenture stud-type attachments at different implant angulations

被引:25
作者
Choi, Jae-Won [1 ]
Bae, Ji-Hyeon [1 ]
Jeong, Chang-Mo [1 ]
Huh, Jung-Bo [1 ]
机构
[1] Pusan Natl Univ, Sch Dent, Dept Prosthodont, Yangsan, South Korea
关键词
RANDOMIZED CLINICAL-TRIAL; IN-VITRO; MANDIBULAR OVERDENTURES; SPHERICAL ATTACHMENTS; PATIENT SATISFACTION; COMPLETE DENTURES; BAR-CLIP; SYSTEMS; FORCES;
D O I
10.1016/j.prosdent.2016.09.027
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Implant angulation should be considered when selecting an attachment. Some in vitro studies have investigated the relationship between implant angulation and changes in the retention force of the stud attachment, but few studies have evaluated the effect of cyclic loading and repeated cycles of insertion and removal on the stud attachment. Purpose. The purpose of this in vitro study was to evaluate the effects of implant angulation on the retentive characteristics of overdentures with 2 different stud attachments, an experimental system and O-rings in red and orange, after cyclic loading and repeated insertion and removal cycles. Material and methods. The canine region of a mandibular experimental model was fitted with 2 implant fixtures with 2 different stud attachment systems at implant angulations of 0, 15, or 30 degrees. A mastication simulator was used to simulate cyclic loading, and a universal testing machine was used to evaluate retentive force changes after repeated insertion and removal cycles. To simulate the numbers of mastication and insertion and removal cycles per annum, 400 000 cyclic loadings and 1080 insertion and removal cycles were performed. Wear patterns and attachment surface deformations were evaluated by scanning electron microscopy. Data were analyzed using the Kruskal-Wallis test, Mann-Whitney U test with Bonferroni correction (alpha=.05/3=.017), and the paired-sample Student t test (alpha=.05). Results. When retentive forces before and after testing were compared, O-ring showed significant retention loss at all implant angulations (P<.001). In contrast, the experimental system showed little retention loss in the 0- and 15-degree models (P>.05), whereas the 30-degree model showed a significant increase in retentive force (P=.001). At all implant angulations, retention loss increased significantly for the orange O-ring, followed by the red O-ring, and the experimental system (P<.001). Scanning electron microscopy analysis showed more intense wear in the matrix than the patrix (abutment that matches to matrix) and more severe wear and deformation of the O-ring rubber matrix than of the experimental zirconia ball. Conclusions. Upon completion of the experiment, wear and deformation were found for all attachment systems. Even when implants are not installed in parallel, the experimental system can be used without involving great loss of retention.
引用
收藏
页码:628 / 635
页数:8
相关论文
共 40 条
[1]   THE IN VITRO EFFECT OF DIFFERENT IMPLANT ANGULATIONS AND CYCLIC DISLODGEMENT ON THE RETENTIVE PROPERTIES OF AN OVERDENTURE ATTACHMENT SYSTEM [J].
Al-Ghafli, Suhail Ali ;
Michalakis, Konstantinos X. ;
Hirayama, Hiroshi ;
Kang, Kiho .
JOURNAL OF PROSTHETIC DENTISTRY, 2009, 102 (03) :140-147
[2]  
Alsabeeha NHM, 2009, INT J PROSTHODONT, V22, P429
[3]   In vitro retention force changes of prefabricated attachments for overdentures [J].
Besimo, CE ;
Guarneri, A .
JOURNAL OF ORAL REHABILITATION, 2003, 30 (07) :671-678
[4]   PATIENT SATISFACTION WITH IMPLANT-RETAINED MANDIBULAR OVERDENTURES - A COMPARISON WITH NEW COMPLETE DENTURES NOT RETAINED BY IMPLANTS - A MULTICENTER RANDOMIZED CLINICAL-TRIAL [J].
BOERRIGTER, EM ;
GEERTMAN, ME ;
VANOORT, RP ;
BOUMA, J ;
RAGHOEBAR, GM ;
VANWAAS, MAJ ;
VANTHOF, MA ;
BOERING, G ;
KALK, W .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 1995, 33 (05) :282-288
[5]   The effect of simulated function on the retention of bar-clip retained removable prostheses [J].
Breeding, LC ;
Dixon, DL ;
Schmitt, S .
JOURNAL OF PROSTHETIC DENTISTRY, 1996, 75 (05) :570-573
[6]  
Bums DR., 1995, J Prosthet Dent, V73, P354
[7]  
Burns D R, 2000, J Prosthodont, V9, P37, DOI 10.1111/j.1532-849X.2000.00037.x
[8]   Photoelastic stress analysis of various retention mechanisms on 3-implant-retained mandibular overdentures [J].
Celik, Gozde ;
Uludag, Bulent .
JOURNAL OF PROSTHETIC DENTISTRY, 2007, 97 (04) :229-235
[9]   FREEDOM OF ROTATION OF SELECTED OVERDENTURE ATTACHMENTS: AN IN VITRO STUDY [J].
Chen, I-Chieh ;
Brudvik, James S. ;
Mancl, Lloyd A. ;
Rubenstein, Jeffrey E. ;
Chitswe, Kinsey ;
Raigrodski, Ariel J. .
JOURNAL OF PROSTHETIC DENTISTRY, 2011, 106 (02) :78-86
[10]  
Chung Kwok-Hung, 2004, J Prosthodont, V13, P221