Lung cancer: Performance of automated lung nodule detection applied to cancers missed in a CT screening program

被引:208
作者
Armato, SG
Li, F
Giger, ML
MacMahon, H
Sone, S
Doi, K
机构
[1] Univ Chicago, Dept Radiol, Kurt Rossmann Labs Radiol Image Res, Chicago, IL 60637 USA
[2] Azumi Gen Hosp, Dept Radiol, Nagano, Japan
关键词
cancer screening; computed tomography (CT); image processing; computers; diagnostic aid; lung neoplasms; CT;
D O I
10.1148/radiol.2253011376
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the performance of a fully automated computerized method for the detection of lung nodules in computed tomographic (CT) scans in the identification of lung cancers that may be missed during visual interpretation. MATERIALS AND METHODS: A database of 38 low-dose CT scans with 50 lung nodules was obtained from a lung cancer screening program. Thirty-eight of the nodules represented biopsy-confirmed lung cancers that had not been reported during initial clinical interpretation. A computer detection method that involved the use of gray-level thresholding techniques to identify three-dimensionally contiguous structures within the lungs was applied to the CT data. Computer-extracted volume was used to determine whether a structure became a nodule candidate. A rule-based scheme and a cascaded automated classifier were applied to the set of nodule candidates to distinguish actual nodes from areas of normal anatomy. Overall performance of the computer detection method was evaluated with free-response receiver operating characteristic (FROC) analysis. RESULTS: At a specific operating point on the FROC curve, the method achieved a sensitivity of 80% (40 of 50 nodules), with an average of 1.0 false-positive detection per section. Missed cancers were detected by the computerized method with a sensitivity of 84% (32 of 38 nodules) and a false-positive rate of 1.0 per section. CONCLUSION: With an automated lung nodule detection method, a large fraction (84%, 32 of 38) of missed cancers in a database of low-dose CT scans were detected correctly. (C) RSNA, 2002.
引用
收藏
页码:685 / 692
页数:8
相关论文
共 39 条
  • [1] Computerized detection of pulmonary nodules on CT scans
    Armato, SG
    Giger, ML
    Moran, CJ
    Blackburn, JT
    Doi, K
    MacMahon, H
    [J]. RADIOGRAPHICS, 1999, 19 (05) : 1303 - 1311
  • [2] Computerized lung nodule detection: comparison of performance for low-dose and standard-dose helical CT scans
    Armato, SG
    Giger, ML
    Doi, K
    Bick, U
    MacMahon, H
    [J]. MEDICAL IMAGING: 2001: IMAGE PROCESSING, PTS 1-3, 2001, 4322 : 1449 - 1454
  • [3] Automated detection of lung nodules in CT scans: Preliminary results
    Armato, SG
    Giger, ML
    MacMahon, H
    [J]. MEDICAL PHYSICS, 2001, 28 (08) : 1552 - 1561
  • [4] Analysis of a three-dimensional lung nodule detection method for thoracic CT scans
    Armato, SG
    Giger, ML
    MacMahon, H
    [J]. MEDICAL IMAGING 2000: IMAGE PROCESSING, PTS 1 AND 2, 2000, 3979 : 103 - 109
  • [5] Three-dimensional approach to lung nodule detection in helical CT
    Armato, SG
    Giger, ML
    Blackburn, JT
    Doi, K
    MacMahon, H
    [J]. MEDICAL IMAGING 1999: IMAGE PROCESSING, PTS 1 AND 2, 1999, 3661 : 553 - 559
  • [6] BUNCH PC, 1977, P SOC PHOTO-OPT INS, V127, P124
  • [7] Pulmonary nodules: Experimental and clinical studies at low-dose CT
    Diederich, S
    Lenzen, H
    Windmann, R
    Puskas, Z
    Yelbuz, TM
    Henneken, S
    Klaiber, T
    Eameri, M
    Roos, N
    Peters, PE
    [J]. RADIOLOGY, 1999, 213 (01) : 289 - 298
  • [8] SCREENING FOR LUNG-CANCER
    EDDY, DM
    [J]. ANNALS OF INTERNAL MEDICINE, 1989, 111 (03) : 232 - 237
  • [9] Automatic detection of pulmonary nodules in low-dose screening thoracic CT examinations
    Fiebich, M
    Wietholt, C
    Renger, BC
    Armato, SG
    Hoffmann, KR
    Wormanns, D
    Diederich, S
    [J]. MEDICAL IMAGING 1999: IMAGE PROCESSING, PTS 1 AND 2, 1999, 3661 : 1434 - 1439
  • [10] COMPUTERIZED DETECTION OF PULMONARY NODULES IN COMPUTED-TOMOGRAPHY IMAGES
    GIGER, ML
    BAE, KT
    MACMAHON, H
    [J]. INVESTIGATIVE RADIOLOGY, 1994, 29 (04) : 459 - 465