A bromide ion-selective polymeric membrane electrode based on a benzo-derivative xanthenium bromide salt

被引:47
作者
Shamsipur, M [1 ]
Rouhani, S
Mohajeri, A
Ganjali, MR
Rashidi-Ranjbar, P
机构
[1] Razi Univ, Dept Chem, Kermanshah, Iran
[2] Bou Ali Sina Univ, Dept Chem, Hamadan, Iran
[3] Univ Tehran, Dept Chem, Tehran, Iran
关键词
bromide ion-selective electrode; 14-phenyldibenzo[a; j]xanthenium bromide; PVC membrane; potentiometry;
D O I
10.1016/S0003-2670(00)00954-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel bromide ion-selective PVC membrane sensor based on 14-phenyldibenzo [a]xanthenium bromide as a membrane carrier was prepared. The electrode has a linear dynamic range between 1.0x10(-1) and 3.2x 10(-5) M with a near-Nernstian slope of 61+/-1 mV per decade and a detection limit of 2.0x10(-5) M. The potentiometric response is independent of the pH of the solution in the pH range 4.5-8.5. The electrode possesses the advantages of low resistance, fast response and good selectivities over a variety of other anions. It was applied as an indicator electrode in potentiometric titration of bromide ions. (C) 2000 Elsevier Science B.V All rights reserved.
引用
收藏
页码:197 / 203
页数:7
相关论文
共 45 条
[1]  
ALEGRET S, 1987, QUIM ANAL, V6, P418
[2]  
Bailey PL, 1996, ANAL ION SELECTIVE E
[3]   Selectivity of liquid membrane ion-selective electrodes [J].
Bakker, E .
ELECTROANALYSIS, 1997, 9 (01) :7-12
[4]   Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors [J].
Buhlmann, P ;
Pretsch, E ;
Bakker, E .
CHEMICAL REVIEWS, 1998, 98 (04) :1593-1687
[5]   INFLUENCE OF PORPHYRIN STRUCTURE ON ANION SELECTIVITIES OF MANGANESE(III) PORPHYRIN BASED MEMBRANE ELECTRODES [J].
CHANIOTAKIS, NA ;
CHASSER, AM ;
MEYERHOFF, ME ;
GROVES, JT .
ANALYTICAL CHEMISTRY, 1988, 60 (02) :185-188
[6]   Iodide-selective electrodes based on the silver(I) complex of a novel N-thiocarbamoylimine-dithioether derivative [J].
ElAamrani, FZ ;
Sastre, A ;
Aguilar, M ;
Beyer, L ;
Florido, A .
ANALYTICA CHIMICA ACTA, 1996, 329 (03) :247-252
[7]   PVC-based hexathia-18-crown-6-tetraone sensor for mercury(II) ions [J].
Fakhari, AR ;
Ganjali, MR ;
Shamsipur, M .
ANALYTICAL CHEMISTRY, 1997, 69 (18) :3693-3696
[8]  
FLORIDO A, 1992, ACS SYM SER, V487, P175
[9]   DETERMINATION OF SELECTIVITY COEFFICIENTS OF ION-SELECTIVE ELECTRODES BY A MATCHED-POTENTIAL METHOD [J].
GADZEKPO, VPY ;
CHRISTIAN, GD .
ANALYTICA CHIMICA ACTA, 1984, 164 (OCT) :279-282
[10]   Beryllium-selective membrane electrode based on benzo-9-crown-3 [J].
Ganjali, MR ;
Moghimi, A ;
Shamsipur, M .
ANALYTICAL CHEMISTRY, 1998, 70 (24) :5259-5263