A novel method for the determination of three volatile organic compounds in exhaled breath by solid-phase microextraction-ion mobility spectrometry

被引:33
作者
Allafchian, Ali Reza [1 ]
Majidian, Zahra [1 ]
Ielbeigi, Vahideh [2 ]
Tabrizchi, Mahmoud [2 ]
机构
[1] Isfahan Univ Technol, Nanotechnol & Adv Mat Inst, Esfahan 8415683111, Iran
[2] Isfahan Univ Technol, Dept Chem, Esfahan 8415683111, Iran
关键词
Gold nanoparticles; Sol gel; Ion mobility spectrometry; Solid-phase microextraction; CHROMATOGRAPHY-MASS SPECTROMETRY; GEL COATINGS; FIBER; LIQUID; NANOPARTICLES; SAMPLES; COPPER; AIR; CLASSIFICATION; EXTRACTION;
D O I
10.1007/s00216-015-9170-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method was carried out for the quantitative determination of the concentrations of volatile organic compounds (VOCs) using solid-phase microextraction and ion mobility spectrometry (SPME-IMS). This method was optimized and evaluated. The best results were obtained at sorption temperature 70 A degrees C, desorption temperature 200 A degrees C, and extraction time 15 min. Under the optimized conditions, the linear dynamic range was found to be 0.01-4.0 ppb (R (2) > 0.995), 2.3-400 ppm (R (2) > 0.994), and 2.5-76 ppb (R (2) > 0.998) for acetone, acetaldehyde, and acetonitrile, respectively. The detection limits for acetone, acetaldehyde, and acetonitrile were 0.001 ppb, 0.18 ppm, and 0.22 ppb, respectively. As a practical application, the method was applied for the determination of acetone, acetaldehyde, and acetonitrile in human breath matrix. Therefore, the proposed method was found to be effective and simple enough to be strongly recommended for real sample analysis.
引用
收藏
页码:839 / 847
页数:9
相关论文
共 44 条
[1]   Corrosion protection of copper by silane sol-gel coatings [J].
Adhami, S. ;
Atapour, M. ;
Allafchian, A. R. .
JOURNAL OF SOL-GEL SCIENCE AND TECHNOLOGY, 2015, 74 (03) :800-809
[2]   Rapid screening of methamphetamines in human serum by headspace solid-phase microextraction using a dodecylsulfate-doped polypyrrole film coupled to ion mobility spectrometry [J].
Alizadeh, Naader ;
Mohammadi, Abdorreza ;
Tabrizchi, Mahmoud .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1183 (1-2) :21-28
[3]  
[Anonymous], 2007, Iran PPatent, Patent No. 42767
[4]   Sample-introduction systems coupled to ion-mobility spectrometry equipment for determining compounds present in gaseous, liquid and solid samples [J].
Arce, L. ;
Menendez, M. ;
Garrido-Delgado, R. ;
Valcarcel, M. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2008, 27 (02) :139-150
[5]   A highly thermal-resistant electrospun-based polyetherimide nanofibers coating for solid-phase microextraction [J].
Bagheri, Habib ;
Akbarinejad, Alireza ;
Aghakhani, Ali .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (08) :2141-2149
[6]   Influence of hydrolysis time on the structure and corrosion protective performance of (3-mercaptopropyl)triethoxysilane film on copper [J].
Chen, Ming-An ;
Lu, Xue-Bin ;
Guo, Zhao-Hui ;
Huang, Rong .
CORROSION SCIENCE, 2011, 53 (09) :2793-2802
[7]  
Chen N.K. Guoping., 2008, The Open Biotechnology Journal, V2, P152
[8]   An investigation on electronic nose diagnosis of lung cancer [J].
D'Amico, Arnaldo ;
Pennazza, Giorgio ;
Santonico, Marco ;
Martinelli, Eugenio ;
Roscioni, Claudio ;
Galluccio, Giovanni ;
Paolesse, Roberto ;
Di Natale, Corrado .
LUNG CANCER, 2010, 68 (02) :170-176
[9]   Determination of acetone in human breath by gas chromatography-mass spectrometry and solid-phase microextraction with on-fiber derivatization [J].
Deng, CH ;
Zhang, J ;
Yu, XF ;
Zhang, W ;
Zhang, XM .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 810 (02) :269-275
[10]   Breath analysis: trends in techniques and clinical applications [J].
Di Francesco, F ;
Fuoco, R ;
Trivella, MG ;
Ceccarini, A .
MICROCHEMICAL JOURNAL, 2005, 79 (1-2) :405-410