Temperature profiles in a controlled-stress parallel plate rheometer

被引:4
|
作者
Barker, Dean A. [1 ]
Wilson, D. Ian [1 ]
机构
[1] Univ Cambridge, Dept Chem Engn, Cambridge CB2 3RA, England
关键词
rheometer; temperature; calibration; solidification; offset; simulation;
D O I
10.1007/s00397-005-0050-6
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Actual melt temperatures are rarely measured directly when conducting rheological characterisations of materials in non-ambient conditions despite the potentially large influence temperature may have on the rheological data. For rheometers that use only a temperature-regulated lower plate, it is likely that the set point and true melt temperatures differ, an effect that becomes significant when characterising melts or suspensions close to phase-change events like crystallisation. This work investigates the magnitude of these effects for a controlled-stress rheometer featuring a temperature-controlled lower plate. The lower plate was fitted with a serrated cover disc that was found to exacerbate temperature deviations from the desired set point. Steady-state radial and vertical temperature profiles within the sample were measured and compared with the predictions of a finite element analysis model. The deviations between set point and measured temperatures were successfully predicted by the simulation for two typical gap heights for a thermoplastic, ceramic paste. The non-ideal heat transfer characteristics were also investigated numerically for a representative polymer system that demonstrated the increased deviations from ideal values for lower thermal conductivity materials.
引用
收藏
页码:23 / 31
页数:9
相关论文
共 50 条
  • [41] A sliding plate microgap rheometer for the simultaneous measurement of shear stress and first normal stress difference
    Baik, Seung Jae
    Moldenaers, Paula
    Clasen, Christian
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (03):
  • [42] Interlaboratory study on low temperature asphalt binder testing using Dynamic Shear Rheometer with 4 mm diameter parallel plate geometry
    Buchner, Johannes
    Wistuba, Michael P.
    Dasek, Ondrej
    Staschkiewicz, Matthias
    Soenen, Hilde
    Zofka, Adam
    Remmler, Torsten
    ROAD MATERIALS AND PAVEMENT DESIGN, 2022, 23 (04) : 890 - 906
  • [43] Fatigue crack density of asphalt binders under controlled-stress rotational shear load testing
    Shi, Chenguang
    Cai, Xing
    Yi, Xingyu
    Wang, Tianling
    Yang, Jun
    CONSTRUCTION AND BUILDING MATERIALS, 2021, 272
  • [44] FLUID INERTIA EFFECTS ON A CONTROLLED STRESS RHEOMETER IN ITS OSCILLATORY MODE
    JONES, TER
    DAVIES, JM
    THOMAS, A
    RHEOLOGICA ACTA, 1987, 26 (01) : 14 - 19
  • [45] CHARGE PROFILES IN PARALLEL-PLATE IONIZATION CHAMBERS
    FERREIRA, GFL
    NUNESDEOLIVEIRA, L
    GROSS, B
    JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS SECTION B-MATHEMATICAL SCIENCES, 1975, 79 (1-2): : 65 - 75
  • [46] Study of the rheological behaviour of human blood using a controlled stress rheometer
    Alves, Maria M.
    Rocha, Cristina
    Goncalves, Maria P.
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2013, 53 (04) : 369 - 386
  • [47] Study of rheological behaviour of polymer melt in micro injection moulding with a miniaturized parallel plate rheometer
    Trotta, G.
    Stampone, B.
    Fassi, I
    Tricarico, L.
    POLYMER TESTING, 2021, 96
  • [48] Comparison of Concentric Cylinder and Parallel Plate Geometries for Asphalt Binder Testing with a Dynamic Shear Rheometer
    Hung, Shawn S.
    Farshidi, Frank
    Jones, David
    Harvey, John T.
    TRANSPORTATION RESEARCH RECORD, 2015, (2505) : 108 - 114
  • [49] CONTROL OF HOT-PLATE TEMPERATURE PROFILES
    HENDERSO.DB
    WITTMAN, FE
    DREICER, H
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1968, 13 (11): : 1557 - &
  • [50] Influence of parallel plate temperature on flame quenching
    Yu, Jian-Liang
    Hu, Chun-Ming
    Li, Jiang-Tao
    Chen, Peng
    Yi, Jun
    Ranshao Kexue Yu Jishu/Journal of Combustion Science and Technology, 2007, 13 (01): : 1 - 4