Relationship of Coronary Calcium on Standard Chest CT Scans With Mortality

被引:97
作者
Hughes-Austin, Jan M. [1 ,2 ]
Dominguez, Arturo, III [3 ]
Allison, Matthew A. [2 ,3 ,4 ]
Wassel, Christina L. [5 ]
Rifkin, Dena E. [2 ,3 ,4 ]
Morgan, Cindy G. [2 ]
Daniels, Michael R. [2 ]
Ikram, Umaira [2 ]
Knox, Jessica B. [2 ]
Wright, C. Michael [6 ]
Criqui, Michael H. [2 ]
Ix, Joachim H. [2 ,3 ,4 ]
机构
[1] Univ Calif San Diego, Sch Med, Dept Orthopaed Surg, San Diego, CA 92161 USA
[2] Univ Calif San Diego, Sch Med, Dept Family Med & Publ Hlth, San Diego, CA 92161 USA
[3] Univ Calif San Diego, Sch Med, Dept Med, San Diego, CA 92161 USA
[4] Vet Affairs San Diego Healthcare Syst, San Diego, CA USA
[5] Univ Pittsburgh, Grad Sch Publ Hlth, Dept Epidemiol, Pittsburgh, PA USA
[6] Scripps Hlth, La Jolla, CA USA
基金
美国国家卫生研究院;
关键词
chest computed tomography; coronary artery calcium; epidemiology; mortality; LOW-DOSE CT; ARTERY CALCIUM; COMPUTED-TOMOGRAPHY; CALCIFICATION; RADIATION; SMOKERS; EVENTS; SCORE; RISK;
D O I
10.1016/j.jcmg.2015.06.030
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES The aim of this study was to determine the correlation between coronary artery calcium (CAC) scores on 3 mm electrocardiography (ECG)-gated computed tomography (CT) scans and standard 6 mm chest CT scans, and to compare relative strength of associations of CAC on each scan type with mortality risk. BACKGROUND Coronary artery calcification predicts cardiovascular disease (CVD) and all-cause mortality, and is typically measured on ECG-gated 3 mm CT scans. Patients undergo standard 6 mm chest CTs for various clinical indications much more frequently, but CAC is not usually quantified. To better understand the usefulness of standard chest CTs to quantify CAC, we conducted a case-control study among persons who had both scan types. METHODS Between 2000 and 2003, 4,544 community-living individuals self- or physician-referred for "whole-body" CT scans, had 3 mm ECG-gated CTs and standard 6 mm chest CTs, and were followed for mortality through 2009. In this nested case-control study, we identified 157 deaths and 494 controls frequency matched (1:3) on age and sex. The Agatston method quantified CAC on both scan types. Unconditional logistic regression determined associations with mortality, accounting for CVD risk factors. RESULTS Participants were 68 11 years of age and 63% male. The Spearman correlation of CAC scores between the 2 scan types was 0.93 (p < 0.001); median CAC scores were lower on 6 mm CTs compared to 3 mm CTs (22 vs.104 Agatston units, p < 0.001). Adjusted for traditional CVD risk factors, each standard deviation higher CAC score on 6 mm CTs was associated with 50% higher odds of death (odds ratio: 1.5; 95% confidence interval: 1.2 to 1.9), similar to 50% higher odds on the 3 mm ECG-gated CTs (odds ratio: 1.5; 95% confidence interval: 1.1 to 1.9). CONCLUSIONS CAC scores on standard 6 mm chest CTs are strongly correlated with 3 mm ECG-gated CTs and similarly predict mortality in community-living individuals. Chest CTs performed for other clinical indications may provide an untapped resource to garner CVD risk information without additional radiation exposure or expense. (C) 2016 by the American College of Cardiology Foundation.
引用
收藏
页码:152 / 159
页数:8
相关论文
共 24 条
  • [1] QUANTIFICATION OF CORONARY-ARTERY CALCIUM USING ULTRAFAST COMPUTED-TOMOGRAPHY
    AGATSTON, AS
    JANOWITZ, WR
    HILDNER, FJ
    ZUSMER, NR
    VIAMONTE, M
    DETRANO, R
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) : 827 - 832
  • [2] Coronary artery calcium score on low-dose computed tomography for lung cancer screening
    Arcadi, Teresa
    Maffei, Erica
    Sverzellati, Nicola
    Mantini, Cesare
    Guaricci, Andrea I.
    Tedeschi, Carlo
    Martini, Chiara
    La Grutta, Ludovico
    Cademartiri, Filippo
    [J]. WORLD JOURNAL OF RADIOLOGY, 2014, 6 (06): : 381 - 387
  • [3] Comparison of ordinal versus Agatston coronary calcification scoring for cardiovascular disease mortality in community-living individuals
    Blair, Katherine J.
    Allison, Matthew A.
    Morgan, Cindy
    Wassel, Christina L.
    Rifkin, Dena E.
    Wright, C. Michael
    Criqui, Michael H.
    Ix, Joachim H.
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (04) : 813 - 818
  • [4] Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
  • [5] Radiation risks potentially associated with low-dose CT screening of adult smokers for lung cancer
    Brenner, DJ
    [J]. RADIOLOGY, 2004, 231 (02) : 440 - 445
  • [6] Projected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007
    de Gonzalez, Amy Berrington
    Mahesh, Mahadevappa
    Kim, Kwang-Pyo
    Bhargavan, Mythreyi
    Lewis, Rebecca
    Mettler, Fred
    Land, Charles
    [J]. ARCHIVES OF INTERNAL MEDICINE, 2009, 169 (22) : 2071 - 2077
  • [7] Coronary calcium as a predictor of coronary events in four racial or ethnic groups
    Detrano, Robert
    Guerci, Alan D.
    Carr, J. Jeffrey
    Bild, Diane E.
    Burke, Gregory
    Folsom, Aaron R.
    Liu, Kiang
    Shea, Steven
    Szklo, Moyses
    Bluemke, David A.
    O'Leary, Daniel H.
    Tracy, Russell
    Watson, Karol
    Wong, Nathan D.
    Kronmal, Richard A.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2008, 358 (13) : 1336 - 1345
  • [8] The National Lung Screening Trial: Overview and Study Design
    Gatsonis, Constantine A.
    [J]. RADIOLOGY, 2011, 258 (01) : 243 - 253
  • [9] Radiation exposure during cardiac CT: Effective doses at multi-detector row CT and electron-beam CT
    Hunold, P
    Vogt, FM
    Schmermund, A
    Debatin, JF
    Kerkhoff, G
    Budde, T
    Erbel, R
    Ewen, K
    Barkhausen, J
    [J]. RADIOLOGY, 2003, 226 (01) : 145 - 152
  • [10] Coronary Artery Calcium Can Predict All-Cause Mortality and Cardiovascular Events on Low-Dose CT Screening for Lung Cancer
    Jacobs, Peter C.
    Gondrie, Martijn J. A.
    van der Graaf, Yolanda
    de Koning, Harry J.
    Isgum, Ivana
    van Ginneken, Bram
    Mali, Willem P. T. M.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (03) : 505 - 511