A Novel Approach to Hematology Testing at the Point of Care

被引:14
作者
Bransky, Avishay [1 ]
Larsson, Anders [2 ]
Aardal, Elisabeth [3 ,4 ]
Ben-Yosef, Yaara [1 ]
Christenson, Robert H. [5 ]
机构
[1] PixCell Med Technol Ltd, Yokneam Ilit, Israel
[2] Uppsala Univ, Dept Med Sci, Uppsala, Sweden
[3] Linkoping Univ, Dept Clin Chem, Linkoping, Sweden
[4] Linkoping Univ, Dept Biomed & Clin Sci, Linkoping, Sweden
[5] Univ Maryland, Sch Med, Baltimore, MD 21201 USA
关键词
TURNAROUND TIME; WAIT TIME; BLOOD; PATIENT; TRANSFUSION;
D O I
10.1093/jalm/jfaa186
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The need for rapid point-of-care (POC) diagnostics is now becoming more evident due to the increasing need for timely results and improvement in healthcare service. With the recent COVID-19 pandemic outbreak, POC has become critical in managing the spread of disease. Applicable diagnostics should be readily deployable, easy to use, portable, and accurate so that they fit mobile laboratories, pop-up treatment centers, field hospitals, secluded wards within hospitals, or remote regions, and can be operated by staff with minimal training. Complete blood count (CBC), however, has not been available at the POC in a simple-to-use device until recently. The HemoScreen, which was recently cleared by the FDA for POC use, is a miniature, easy-to-use instrument that uses disposable cartridges and may fill this gap. Content: The HemoScreen's analysis method, in contrast to standard laboratory analyzers, is based on machine vision (image-based analysis) and artificial intelligence (AI). We discuss the different methods currently used and compare their results to the vision-based one. The HemoScreen is found to correlate well to laser and impedance-based methods while emphasis is given to mean cell volume (MCV), mean cell hemoglobin (MCH), and platelets (PLT) that demonstrate better correlation when the vision-based method is compared to itself due to the essential differences between the underlying technologies. Summary: The HemoScreen analyzer demonstrates lab equivalent performance, tested at different clinical settings and sample characteristics, and might outperform standard techniques in the presence of certain interferences. This new approach to hematology testing has great potential to improve quality of care in a variety of settings.
引用
收藏
页码:532 / 542
页数:11
相关论文
共 32 条
  • [1] Abbott Core Laboratory, CELL DYN SAPPHIRE HE
  • [2] Turnaround Time for Red Blood Cell Transfusion in the Hospitalized Patient: A Single-Center "Blood Ordering, Requisitioning, Blood Bank, Issue (of Blood), and Transfusion Delay" Study
    Agnihotri, Naveen
    Agnihotri, Ajju
    [J]. INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2018, 22 (12) : 825 - 830
  • [3] [Anonymous], J ONCOL PRACT
  • [4] Blumberg Neil, 2010, F1000 Med Rep, V2, P5, DOI 10.3410/M2-5
  • [5] Boulassel Mohamed-Rachid, 2015, Sultan Qaboos Univ Med J, V15, pe463, DOI 10.18295/squmj.2015.15.04.004
  • [6] Davis B, 1999, LAB HEMATOL, V5, P15
  • [7] The viscosity of the blood in narrow capillary tubes
    Fahraeus, R
    Lindqvist, T
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1931, 96 (03): : 562 - 568
  • [8] FDA, 510 K SUMMARY K18002
  • [9] FDA, SYSMEX XN 510 K K112
  • [10] Find A Lab Test, TOP 10 BLOOD TESTS O