Normal range values for thromboelastography in healthy adult volunteers

被引:49
作者
Scarpelini, S. [1 ,3 ]
Rhind, S. G. [2 ]
Nascimento, B. [1 ]
Tien, H. [1 ]
Shek, P. N. [2 ]
Peng, H. T. [2 ]
Huang, H. [2 ]
Pinto, R. [1 ]
Speers, V. [1 ]
Reis, M. [1 ]
Rizoli, S. B. [1 ]
机构
[1] Univ Toronto, Sunnybrook Hlth Sci Ctr, Toronto, ON M4N 3M5, Canada
[2] Def Res & Dev Canada, Toronto, ON, Canada
[3] Univ Sao Paulo, Fac Med Ribeirao Preto, Dept Cirurgia, Ribeirao Preto, SP, Brazil
关键词
Coagulation; Thromboelastography; Normal values; WHOLE-BLOOD; CITRATE STORAGE; COAGULATION; THROMBELASTOGRAPHY; TRANSFUSION; TRAUMA; HYPERCOAGULABILITY; ABNORMALITIES; CHILDREN; MARKERS;
D O I
10.1590/S0100-879X2009007500002
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Thromboelastography (TEG (R)) provides a functional evaluation of coagulation. It has characteristics of an ideal coagulation test for trauma, but is not frequently used, partially due to lack of both standardized techniques and normal values. We determined normal values for our population, compared them to those of the manufacturer and evaluated the effect of gender, age, blood type, and ethnicity. The technique was standardized using citrated blood, kaolin and was performed on a Haemoscope 5000 device. Volunteers were interviewed and excluded if pregnant, on anticoagulants or having a bleeding disorder. The TEG (R) parameters analyzed were R, K, alpha, MA, LY30, and coagulation index. All volunteers outside the manufacturer's normal range underwent extensive coagulation investigations. Reference ranges for 95% for 118 healthy volunteers were R: 3.8-9.8 min, K: 0.7-3.4 min, alpha: 47.8-77.7 degrees, MA: 49.7-72.7 mm, LY30: -2.3-5.77%, coagulation index: -5.1-3.6. Most values were significantly different from those of the manufacturer, which would have diagnosed coagulopathy in 10 volunteers, for whom additional investigation revealed no disease (81% specificity). Healthy women were significantly more hypercoagulable than men. Aging was not associated with hypercoagulability and East Asian ethnicity was not associated with hypocoagulability. In our population, the manufacturer's normal values for citrated blood-kaolin had a specificity of 81% and would incorrectly identify 8.5% of the healthy volunteers as coagulopathic. This study supports the manufacturer's recommendation that each institution should determine its own normal values before adopting TEG (R), a procedure which may be impractical. Consideration should be given to a multi-institutional study to establish wide standard values for TEG (R).
引用
收藏
页码:1210 / 1217
页数:8
相关论文
共 50 条
  • [41] Contrast-enhanced MRI findings of the knee in healthy children; establishing normal values
    Robert Hemke
    J. Merlijn van den Berg
    Charlotte M. Nusman
    E. Charlotte van Gulik
    Anouk M. Barendregt
    Dieneke Schonenberg-Meinema
    Koert M. Dolman
    Taco W. Kuijpers
    Mario Maas
    European Radiology, 2018, 28 : 1167 - 1174
  • [42] Acoustic radiation force impulse imaging: normal values of spleen stiffness in healthy children
    Sylviane Hanquinet
    Céline Habre
    Méryle Laurent
    Mehrak Anooshiravani
    Seema Toso
    Pediatric Radiology, 2021, 51 : 1873 - 1878
  • [43] Phase 1 Safety, Tolerability and Pharmacokinetics of 3K3A-APC in Healthy Adult Volunteers
    Lyden, Patrick
    Levy, Howard
    Weymer, Sara
    Pryor, Kent
    Kramer, William
    Griffin, John H.
    Davis, Thomas P.
    Zlokovic, Berislav
    CURRENT PHARMACEUTICAL DESIGN, 2013, 19 (42) : 7479 - 7485
  • [44] Contrast-enhanced MRI findings of the knee in healthy children; establishing normal values
    Hemke, Robert
    van den Berg, J. Merlijn
    Nusman, Charlotte M.
    van Gulik, E. Charlotte
    Barendregt, Anouk M.
    Schonenberg-Meinema, Dieneke
    Dolman, Koert M.
    Kuijpers, Taco W.
    Maas, Mario
    EUROPEAN RADIOLOGY, 2018, 28 (03) : 1167 - 1174
  • [45] Left Ventricular Diastolic Function in Healthy Adult Individuals: Results of the World Alliance Societies of Echocardiography Normal Values Study
    Miyoshi, Tatsuya
    Addetia, Karima
    Citro, Rodolfo
    Daimon, Masao
    Desale, Sameer
    Fajardo, Pedro Gutierrez
    Kasliwal, Ravi R.
    Kirkpatrick, James N.
    Monaghan, Mark J.
    Muraru, Denisa
    Ogunyankin, Kofo O.
    Park, Seung Woo
    Ronderos, Ricardo E.
    Sadeghpour, Anita
    Scalia, Gregory M.
    Takeuchi, Masaaki
    Tsang, Wendy
    Tucay, Edwin S.
    Rodrigues, Ana Clara Tude
    Vivekanandan, Amuthan
    Zhang, Yun
    Blitz, Alexandra
    Lang, Roberto M.
    Asch, Federico M.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2020, 33 (10) : 1223 - 1233
  • [46] Reference range values of hematological parameters in Saudi healthy adults
    Al-Buhairan, AM
    Khalil, SH
    Oluboyede, OA
    SAUDI MEDICAL JOURNAL, 1999, 20 (10) : 757 - 762
  • [47] The impact of sample site and storage on thromboelastography values
    Tuovila, Mari
    Erkinaro, Tiina
    Savolainen, Eeva-Riitta
    Laurila, Paivi
    Ohtonen, Pasi
    Ala-Kokko, Tero
    AMERICAN JOURNAL OF HEMATOLOGY, 2017, 92 (08) : E160 - E162
  • [48] Comparison of venous sampling methods for thromboelastography in clinically normal dogs
    Walker, Julie M.
    Hanel, Rita M.
    Hansen, Bernard D.
    Motsinger-Reif, Alison A.
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2012, 73 (12) : 1864 - 1870
  • [49] Prospective Longitudinal Study of Thromboelastography and Standard Hemostatic Laboratory Tests in Healthy Women During Normal Pregnancy
    Karlsson, Ove
    Sporrong, Tommy
    Hillarp, Andreas
    Jeppsson, Anders
    Hellgren, Margareta
    ANESTHESIA AND ANALGESIA, 2012, 115 (04) : 890 - 898
  • [50] The Stability of Analytes of Ionized Magnesium Concentration and Its Reference Range in Healthy Volunteers
    Al-Maqbali, Juhaina Salim
    Al Alawi, Abdullah M.
    Al-Falahi, Zubaida
    Falhammar, Henrik
    Al-Zakwani, Ibrahim
    Al Za'abi, Mohammed
    BIOMEDICINES, 2023, 11 (09)