Relationship of Anatomy and Function: External Anal Sphincter on Transperineal Ultrasound and Anal Incontinence

被引:7
|
作者
Paka, Chandhana [1 ,2 ]
Atan, Ixora Kamisan [1 ,3 ]
Rios, Rebeca [4 ]
Dietz, Hans Peter [1 ]
机构
[1] Nepean Hosp, Sydney Med Sch Nepean, Penrith, NSW, Australia
[2] Johns Hopkins Sch Med, Dept Gynecol & Obstet, Baltimore, MD USA
[3] Univ Kebangsaan Malaysia, Med Ctr, Dept Obstet & Gynaecol, Kuala Lumpur, Malaysia
[4] Johns Hopkins Sch Med, Biostat Epidemiol & Data Management BEAD Core, Baltimore, MD USA
来源
FEMALE PELVIC MEDICINE AND RECONSTRUCTIVE SURGERY | 2017年 / 23卷 / 04期
关键词
anal incontinence; OASIs; obstetric anal sphincter injuries; St Mark's incontinence score; transperineal ultrasound; PELVIC ORGAN PROLAPSE; QUALITY-OF-LIFE; FECAL INCONTINENCE; URINARY-INCONTINENCE; VAGINAL DELIVERY; PRIMARY REPAIR; RISK-FACTORS; ENDOANAL ULTRASONOGRAPHY; FLOOR DYSFUNCTION; UNITED-STATES;
D O I
10.1097/SPV.0000000000000350
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: The aim of this study was to investigate the association of the anatomic integrity of the external anal sphincter (EAS) detected on transperineal ultrasound (TPUS) with symptoms of anal incontinence (AI) as measured by St Mark's Incontinence Score (SMIS) and the visual analog scale (VAS). Methods: This is an observational, cross-sectional analysis of 486 women who presented to a tertiary urogynecological center between May 2013 and August 2014. They underwent a standardized interview and an examination that involved 3-dimensional/4-dimensional TPUS. The SMIS and VAS were administered if they answered positively to a question on AI. The association between defects of the EAS and symptoms of AI was evaluated using bivariate tests, as well as adjusting for pertinent covariates using multiple linear regression modeling. Results: Of the included patients, 17.1% reported AI, and 15.2% had significant EAS defects (>= 4 slices) on TPUS imaging. A significant sono-graphic defect was diagnosed in 23% of women with AI versus 14% of those without (P = 0.033). Women with symptoms of AI were more likely to have a significant defect on TPUS (odds ratio, 1.878; 95% confidence interval, 1.05-3.37). No significant findings were seen when analyzing SMIS, its components, and VAS against sonographic EAS defects. Conclusions: The symptom of AI is associated with significant EAS defects detected on TPUS. However, this study failed to show an association between significant EAS defects and the SMIS and VAS.
引用
收藏
页码:238 / 243
页数:6
相关论文
共 50 条
  • [21] Correlations of obstetric anal sphincter injury (OASIS) grade, specific symptoms of anal incontinence, and measurements by endoanal and transperineal ultrasound
    Claes Ignell
    Ann-Kristin Örnö
    Andrea Stuart
    Journal of Ultrasound, 2021, 24 : 261 - 267
  • [22] The evolution of transperineal ultrasound findings of the external anal sphincter during the first years after childbirth
    Shek, Ka Lai
    Della Zazzera, Vincent
    Atan, Ixora Kamisan
    Rojas, Rodrigo Guzman
    Langer, Susanne
    Dietz, Hans Peter
    INTERNATIONAL UROGYNECOLOGY JOURNAL, 2016, 27 (12) : 1899 - 1903
  • [23] Three-dimensional transperineal ultrasound findings associated with anal incontinence after intrapartum sphincter tears in primiparous women
    Valsky, D. V.
    Cohen, S. M.
    Lipschuetz, M.
    Hochner-Celnikier, D.
    Yagel, S.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2012, 39 (01) : 83 - 90
  • [24] Pilot study comparing tolerance of transperineal and endoanal ultrasound examination of anal sphincter
    Hubka, P.
    Svabik, K.
    Masata, J.
    Martan, A.
    CESKA GYNEKOLOGIE-CZECH GYNAECOLOGY, 2019, 84 (02): : 111 - 114
  • [25] Anal incontinence, urinary incontinence and sexual problems in primiparous women - a comparison between women with episiotomy only and women with episiotomy and obstetric anal sphincter injury
    Stedenfeldt, Mona
    Pirhonen, Jouko
    Blix, Ellen
    Wilsgaard, Tom
    Vonen, Barthold
    Oian, Pal
    BMC WOMENS HEALTH, 2014, 14
  • [26] Dynamic 2-dimensional transperineal ultrasound evaluation in labor room as a screening tool for anal sphincter injuries and anal incontinence in primiparous women
    Bellussi, Federica
    Montaguti, Elisa
    Youssef, Aly
    Salsi, Ginevra
    Ghi, Tullio
    Pilu, Gianluigi
    AMERICAN JOURNAL OF OBSTETRICS & GYNECOLOGY MFM, 2019, 1 (03)
  • [27] Risk of obstetric anal sphincter injuries (OASIS) and anal incontinence: A meta-analysis
    Sideris, Michail
    McCaughey, Tristan
    Hanrahan, John Gerrard
    Arroyo-Manzano, David
    Zamora, Javier
    Jha, Swati
    Knowles, Charles H.
    Thakar, Ranee
    Chaliha, Charlotte
    Thangaratinam, Shakila
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2020, 252 : 303 - 312
  • [28] Is endoanal, introital or transperineal ultrasound diagnosis of sphincter defects more strongly associated with anal incontinence?
    Ingrid Volløyhaug
    Annika Taithongchai
    Linda Arendsen
    Isabelle van Gruting
    Abdul H. Sultan
    Ranee Thakar
    International Urogynecology Journal, 2020, 31 : 1471 - 1478
  • [29] Can transperineal ultrasound improve the diagnosis of obstetric anal sphincter injuries?
    Wong, Ka Woon
    Thakar, Ranee
    Sultan, Abdul H.
    Andrews, Vasanth
    INTERNATIONAL UROGYNECOLOGY JOURNAL, 2022, 33 (10) : 2809 - 2814
  • [30] The relationship between residual sphincter damage after primary repair, faecal incontinence, and anal sphincter function in primiparous women with an obstetric anal sphincter injury
    Patton, Vicki
    Kumar, Swetha
    Parkin, Katrina
    Karantanis, Emmanuel
    Dinning, Phil
    NEUROUROLOGY AND URODYNAMICS, 2019, 38 (01) : 193 - 199