A general method for bead-enhanced quantitation by flow cytometry

被引:45
作者
Montes, Martin
Jaensson, Elin A.
Rozco, Aaron F.
Lewis, Dorothy E.
Corry, David B.
机构
[1] Baylor Coll Med, Dept Med, Houston, TX 77030 USA
[2] Baylor Coll Med, Dept Immunol, Houston, TX 77030 USA
关键词
flow cytometry; cell quantitation; T cell; eosinophil; apoptotic body;
D O I
10.1016/j.jim.2006.09.013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Flow cytometry provides accurate relative cellular quantitation (percent abundance) of cells from diverse samples, but technical limitations of most flow cytometers preclude accurate absolute quantitation. Several quantitation standards are now commercially available which, when added to samples, permit absolute quantitation of CD4+ T cells. However, these reagents are limited by their cost, technical complexity, requirement for additional software and/or limited applicability. Moreover, few studies have validated the use of such reagents in complex biological samples, especially for quantitation of non-T cells. Here we show that addition to samples of known quantities of polystyrene fluorescence standardization beads permits accurate quantitation of CD4+ T cells from complex cell samples. This procedure, here termed single bead-enhanced cytofluorimetry (SBEC), was equally capable of enumerating eosinophils as well as subcellular fragments of apoptotic cells, moieties with very different optical and fluorescent characteristics. Relative to other proprietary products, SBEC is simple, inexpensive and requires no special software, suggesting that the method is suitable for the routine quantitation of most cells and other particles by flow cytometry. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:45 / 55
页数:11
相关论文
共 17 条
[1]  
Barnett D, 1996, CYTOMETRY, V26, P216, DOI 10.1002/(SICI)1097-0320(19960915)26:3<216::AID-CYTO6>3.0.CO
[2]  
2-C
[3]  
Barnett D, 1999, BRIT J HAEMATOL, V106, P1059
[4]   Cell-free fetal DNA in maternal blood: kinetics, source and structure [J].
Bischoff, FZ ;
Lewis, DE ;
Simpson, JL .
HUMAN REPRODUCTION UPDATE, 2005, 11 (01) :59-67
[5]   Requirements for allergen-induced airway hyperreactivity in T and B cell-deficient mice [J].
Corry, DB ;
Grunig, G ;
Hadeiba, H ;
Kurup, VP ;
Warnock, ML ;
Sheppard, D ;
Rennick, DM ;
Locksley, RM .
MOLECULAR MEDICINE, 1998, 4 (05) :344-355
[6]   Essential role of lung plasmacytoid dendritic cells in preventing asthmatic reactions to harmless inhaled antigen [J].
de Heer, HJ ;
Hammad, H ;
Soullié, T ;
Hijdra, D ;
Vos, N ;
Willart, MAM ;
Hoogsteden, HC ;
Lambrecht, BN .
JOURNAL OF EXPERIMENTAL MEDICINE, 2004, 200 (01) :89-98
[7]  
DOLBEARE FA, 1977, CLIN CHEM, V23, P1485
[8]  
GRAY JI, 1977, CAN I FOOD SC TECH J, V10, P97, DOI 10.1111/j.1365-2184.1977.tb00135.x
[9]   High-grade loss of leukocytes and hematopoietic progenitor cells caused by erythrocyte-lysing procedures for flow cytometric analyses [J].
Greve, B ;
Beller, C ;
Cassens, U ;
Sibrowski, W ;
Severin, E ;
Göhde, W .
JOURNAL OF HEMATOTHERAPY & STEM CELL RESEARCH, 2003, 12 (03) :321-330
[10]   The impact of erythrocyte lysing procedures on the recovery of hematopoietic progenitor cells in flow cytometric analysis [J].
Greve, Burkhard ;
Beller, Constanze ;
Cassens, Uwe ;
Sibrowski, Walter ;
Goehde, Wolfgang .
STEM CELLS, 2006, 24 (03) :793-799