Primary stability and viscoelastic displacement of mini-implant system under loading

被引:13
作者
Lee, Jim [1 ]
Jeong, Yong-Hoon [1 ]
Pittman, Joseph [1 ]
Deguchi, Toru [1 ]
Johnston, William M. [2 ]
Fields, Henry W. [1 ]
Kim, Do-Gyoon [1 ]
机构
[1] Ohio State Univ, Coll Dent, Div Orthodont, 4088 Postle Hall,305 W 12th Ave, Columbus, OH 43210 USA
[2] Ohio State Univ, Coll Dent, Div Gen Practice & Mat Sci, Columbus, OH 43210 USA
关键词
Mini-implant; Diameter; Orthodontic loading; Creep; Bone mineral density; Thickness; ORTHODONTIC MINISCREW IMPLANTS; TISSUE MINERAL DENSITY; CORTICAL BONE; ROOT PROXIMITY; ANCHORAGE; FAILURE; VARIABILITY; STRENGTH; BEHAVIOR; SUCCESS;
D O I
10.1016/j.clinbiomech.2016.11.004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: The objectives of the current study were to examine the effects of mini-implant diameters on 1) primary stability before bone properties are changed by active peri-implant bone remodeling and 2) the time-dependent displacement of mini-implant systems in bone under a functional radial loading and their associations with bone mineral density. Methods: Twenty one, 8 mm length mini-implants (7 each for 1.4 mm, 1.6 mm, and 2 mm diameters) were placed in mandibular sections of human cadavers (4 males and 3 females, average 69.7 (SD 13.1) years of age). Displacement of the mini-implant in wet bone was assessed during initial and subsequent continuous radial loading of 2 N in the mediolateral direction for 2 h. Mean, standard deviation and coefficient of variation of peri-implant bone mineral density were obtained using histograms of cone-beam computed tomography attenuation values. The cortical thickness along with the miniscrew site was also measured. Findings: The primary stability and displacement of mini-implants in bone were not significantly different between the 3 diameter groups (p > 0.147, n = 21). Moderate positive correlations of time-dependent viscoelastic displacement (creep) were found with bone mineral density variability independent of the mini-implant diameters (p > 0.11). Interpretation: The post-implantation displacements of mini-implant suggested that the orthodontic treatment loading can develop micromotion between the mini-implant and surrounding bone leading to reduction of its primary stability. Current findings also provide an insight that peri-implant bone mineral density variability plays an important role in controlling displacement of the mini-implant, which determine its stability during early and prolonged orthodontic treatment loading periods. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:28 / 33
页数:6
相关论文
共 36 条
[1]   Bicortical vs monocortical orthodontic skeletal anchorage [J].
Brettin, Bryan T. ;
Grosland, Nicole M. ;
Qian, Fang ;
Southard, Karin A. ;
Stuntz, Tony D. ;
Morgan, Teresa A. ;
Marshall, Steve D. ;
Southard, Thomas E. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 134 (05) :625-635
[2]  
Brunski J B, 1999, Adv Dent Res, V13, P99
[3]   Increased calcium content and inhomogeneity of mineralization render bone toughness in osteoporosis: Mineralization, morphology and biomechanics of human single trabeculae [J].
Busse, Bjoern ;
Hahn, Michael ;
Soltau, Markus ;
Zustin, Jozef ;
Pueschel, Klaus ;
Duda, Georg N. ;
Amling, Michael .
BONE, 2009, 45 (06) :1034-1043
[4]   Miniscrew stability evaluated with computerized tomography scanning [J].
Cha, Jung-Yul ;
Kil, Jae-Kyoung ;
Yoon, Tae-Min ;
Hwang, Chung-Ju .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (01) :73-79
[5]   Influence of surface characteristics on survival rates of mini-implants [J].
Chaddad, Karim ;
Ferreira, Andre F. H. ;
Geurs, Nico ;
Reddy, Michael S. .
ANGLE ORTHODONTIST, 2008, 78 (01) :107-113
[6]   Critical factors for the success of orthodontic mini-implants: A systematic review [J].
Chen, Yan ;
Kyung, Hee Moon ;
Zhao, Wen Ting ;
Yu, Won Jae .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 135 (03) :284-291
[7]   Miniscrews in orthodontic treatment: Review and analysis of published clinical trials [J].
Crismani, Adriano G. ;
Bertl, Michael H. ;
Celar, Ales G. ;
Bantleon, Hans-Peter ;
Burstone, Charles J. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (01) :108-113
[8]   Factors affecting stresses in cortical bone around miniscrew implants A three-dimensional finite element study [J].
Duaibis, Ramzi ;
Kusnoto, Budi ;
Natarajan, Raghu ;
Zhao, Linping ;
Evans, Carla .
ANGLE ORTHODONTIST, 2012, 82 (05) :875-880
[9]   Cortical bone thickness at common miniscrew implant placement sites [J].
Farnsworth, David ;
Rossouw, P. Emile ;
Ceen, Richard F. ;
Buschang, Peter H. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 139 (04) :495-503
[10]  
Garetto L P, 1995, Implant Dent, V4, P235, DOI 10.1097/00008505-199500440-00002