Capacitive sensor based on molecularly imprinted polymers for detection of the insecticide imidacloprid in water

被引:50
作者
El-Akaad, Suzan [1 ,2 ]
Mohamed, Mona A. [2 ]
Abdelwahab, Nada S. [3 ]
Abdelaleem, Eglal A. [3 ]
De Saeger, Sarah [1 ]
Beloglazova, Natalia [1 ,4 ,5 ]
机构
[1] Univ Ghent, Fac Pharmaceut Sci, Ctr Excellence Mycotoxicol & Publ Hlth, Ghent, Belgium
[2] Natl Org Drug Control & Res NODCAR, Dept Pharmaceut Chem, Giza, Egypt
[3] Beni Suef Univ, Fac Pharmaceut Sci, Dept Analyt Chem, Bani Suwayf, Egypt
[4] South Ural State Univ, Nanotechnol Educ & Res Ctr, Chelyabinsk, Russia
[5] Saratov NG Chernyshevskii State Univ, Chem Inst, Dept Gen & Inorgan Chem, Saratov, Russia
关键词
SOLID-PHASE EXTRACTION; CARBON NANOTUBES; IMMUNOSENSOR; METABOLITES; FLUORESCENT; MEMBRANES; TOXICITY;
D O I
10.1038/s41598-020-71325-y
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This manuscript reports on the development of a capacitive sensor for the detection of imidacloprid (IMD) in water samples based on molecularly imprinted polymers (MIPs). MIPs used as recognition elements were synthesized via a photo-initiated emulsion polymerization. The particles were carefully washed using a methanol (MeOH) / acetic acid mixture to ensure complete template removal and were then dried. The average size of the obtained particles was less than 1 mu m. The imprinting factor (IF) for IMD was 6 and the selectivity factor (alpha) for acetamiprid, clothianidin, thiacloprid and thiamethoxam were 14.8, 6.8, 7.1 and 8.2, respectively. The particles were immobilized on the surface of a gold electrode by electropolymerization. The immobilized electrode could be spontaneously regenerated using a mixture of MeOH/10 mM of phosphate buffer (pH = 7.2)/triethylamine before each measurement and could be reused for 32 times. This is the first-time that automated regeneration was introduced as part of a sensing platform for IMD detection. The developed sensor was validated by the analysis of artificially spiked water samples. Under the optimal conditions, the linearity was in the range of 5-100 mu M, with a limit of detection (LOD) of 4.61 mu M.
引用
收藏
页数:10
相关论文
共 44 条
[1]   Novel potentiometric sensors for the determination of the dinotefuran insecticide residue levels in cucumber and soil samples [J].
Abdel-Ghany, Maha F. ;
Hussein, Lobna A. ;
El Azab, Noha F. .
TALANTA, 2017, 164 :518-528
[2]   Molecularly imprinted mesoporous silica embedded with carbon dots and semiconductor quantum dots as a ratiometric fluorescent sensor for diniconazole [J].
Amjadi, Mohammad ;
Jalili, Roghayeh .
BIOSENSORS & BIOELECTRONICS, 2017, 96 :121-126
[3]   Uptake and translocation monitoring of imidacloprid to chili and tomato plants by molecularly imprinting extraction - ion mobility spectrometry [J].
Aria, M. M. ;
Sorribes-Soriano, A. ;
Jafari, M. T. ;
Nourbakhsh, F. ;
Esteve-Turrillas, F. A. ;
Armenta, S. ;
Herrero-Martinez, J. M. ;
de la Guardia, M. .
MICROCHEMICAL JOURNAL, 2019, 144 :195-202
[4]   Electrochemical impedimetric sensor based on molecularly imprinted polymers/sol-gel chemistry for methidathion organophosphorous insecticide recognition [J].
Bakas, Idriss ;
Hayat, Akhtar ;
Piletsky, Sergey ;
Piletska, Elena ;
Chehimi, Mohamed M. ;
Noguer, Thierry ;
Rouillon, Regis .
TALANTA, 2014, 130 :294-298
[5]  
Bakirhan NK, 2018, FOOD SAFETY AND PRESERVATION: MODERN BIOLOGICAL APPROACHES TO IMPROVING CONSUMER HEALTH, P91, DOI 10.1016/B978-0-12-814956-0.00005-6
[6]   On-Line Monitoring Imidacloprid and Thiacloprid in Celery Juice Using Quartz Crystal Microbalance [J].
Bi, Xinyan ;
Yang, Kun-Lin .
ANALYTICAL CHEMISTRY, 2009, 81 (02) :527-532
[7]   Molecularly imprinted polymer for selective adsorption of diclofenac from contaminated water [J].
Cantarella, Maria ;
Carroccio, Sabrina C. ;
Dattilo, Sandro ;
Avolio, Roberto ;
Castaldo, Rachele ;
Puglisi, Concetto ;
Privitera, Vittorio .
CHEMICAL ENGINEERING JOURNAL, 2019, 367 :180-188
[8]   Determination of imidacloprid in rice by molecularly imprinted-matrix solid-phase dispersion with liquid chromatography tandem mass spectrometry [J].
Chen, Ligang ;
Li, Bin .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 897 :32-36
[9]   3D Bismuth Ferrite Microflowers Electrochemical Sensor for the Multiple Detection of Pesticides [J].
El-Akaad, Suzan ;
Mohamed, Mona A. ;
Elmasri, Moustafa M. ;
Abdelwahab, Nada S. ;
Abdelaleem, Eglal A. ;
De Saeger, Sarah ;
Beloglazova, Natalia .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2020, 167 (02)
[10]   Automated flow-injection immunosensor based on current pulse capacitive measurements [J].
Erlandsson, Dag ;
Teeparuksapun, Kosin ;
Mattiasson, Bo ;
Hedstrom, Martin .
SENSORS AND ACTUATORS B-CHEMICAL, 2014, 190 :295-304