Patient-prosthesis mismatch does not affect survival following aortic valve replacement

被引:70
|
作者
Howell, Neil J. [1 ]
Keogh, Bruce E. [1 ]
Barnet, Vivien [1 ]
Bonser, Robert S. [1 ]
Graham, Timothy R. [1 ]
Rooney, Stephen J. [1 ]
Wilson, Ian C. [1 ]
Pagano, Domenico [1 ]
机构
[1] Univ Hosp NHS Fdn Trust, Dept Cardiothorac Surg, Birmingham, W Midlands, England
关键词
aortic valve disease; aortic valve replacement;
D O I
10.1016/j.ejcts.2006.03.046
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Patient-prosthesis mismatch (PPM) has been reported to increase perioperative mortality and reduce postoperative survival in patients undergoing aortic valve replacement (AVR). We analysed the effect of PPM at values predicting severe mismatch on survival following AVR in our unit. Methods: Prospectively collected data on 1481 consecutive patients who had undergone AVR with or without coronary artery revascularisation between 1997 and 2005 were analysed. Projected in vitro valve effective orifice area (EOA) and geometric prosthesis internal orifice area (GOA) were evaluated and values were indexed to body surface area (cm(2) m(-2)). PPM was defined as EOAi < 0.6 and/or GOAi < 1.1. Long-term survival data were obtained from the National Institute of Statistics. Results: One thousand four hundred and eighteen patients were identified. 67/1418 (4.7%) patients had GOAi < 1.1; 122/1418 (8.6%) had EOAi < 0.6 and 38 (2.6%) patients exhibited both forms of mismatch. One thousand two hundred and sixty-seven patients (89%) demonstrated no mismatch (reference group). There were 75 in-hospital deaths (overall mortality 5.3%) with no significant difference between the mismatch and the reference groups. Survival data were available for up to 8 years (median 36 months, IQR 6-60 months). There were 160 late deaths (13/143 PPM group vs 147/1198 reference group). The 5-year survival estimate was similar for both groups (83% PPM group; 81% reference group; p = 0.47). Cox-hazard analysis identified advanced age as the only predictor of reduced survival (age > 80, RR 2.13, 95% CI 1.38-4.586, p = 0.004). Conclusions: Severe patient-prosthesis mismatch was predicted in 4-10% of patients undergoing AVR but this did not affect in-hospital mortality or mid-term survival. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:10 / 14
页数:5
相关论文
共 50 条
  • [41] Mini-aortic valve replacements are not associated with an increased incidence of patient-prosthesis mismatch: a propensity-scored analysis
    Magruder, J. Trent
    Grimm, Joshua C.
    Kilic, Arman
    Crawford, Todd
    Conte, John V.
    Cameron, Duke E.
    Shah, Ashish S.
    GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2016, 64 (03) : 144 - 148
  • [42] Patient-Prosthesis Mismatch in Contemporary Small-Size Mechanical Prostheses Does Not Impact Survival at 10 Years
    Feier, Horea
    Mocan, Mihaela
    Grigorescu, Andrei
    Falnita, Lucian
    Gaspar, Marian
    Luca, Constantin-Tudor
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2022, 9 (02)
  • [43] Avoiding Patient-Prosthesis Mismatch Is TAVI a New Solution?
    Stewart, William J.
    Rodriguez, L. Leonardo
    JACC-CARDIOVASCULAR IMAGING, 2011, 4 (10) : 1063 - 1066
  • [44] Defining Patient-Prosthesis Mismatch and Its Effect on Survival in Patients With Impaired Ejection Fraction
    Cotoni, David A.
    Palac, Robert T.
    Dacey, Lawrence J.
    O'Rourke, Daniel J.
    ANNALS OF THORACIC SURGERY, 2011, 91 (03) : 692 - 699
  • [45] Update on aortic valve prosthesis-patient mismatch in Japan
    Sakamoto Y.
    Hashimoto K.
    General Thoracic and Cardiovascular Surgery, 2013, 61 (12) : 669 - 675
  • [46] Impact of Prosthesis Size and Prosthesis-Patient Mismatch on Outcomes in Younger Female Patients Undergoing Aortic Valve Replacement
    Kolkailah, Ahmed A.
    Hirji, Sameer A.
    Ejiofor, Julius I.
    Del Val, Fernando Ramirez
    Chowdhury, Ritam
    McGurk, Siobhan
    Lee, Jiyae
    Kaneko, Tsuyoshi
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2020, 32 (02) : 219 - 228
  • [47] Relative prosthesis-patient mismatch after transcatheter aortic valve replacement: The impact of morbid obesity
    Airhart, Sophia
    Medvedev, Ivan
    Dean, Larry S.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 90 (02) : 341 - 345
  • [48] Impact of different values of prosthesis-patient mismatch on outcome in male patients with aortic valve replacement
    Mannacio, Vito A.
    Mannacio, Luigi
    Antignano, Anita
    Pinna, Giovanni B.
    Giordano, Raffaele
    Mottola, Michele
    Iannelli, Gabriele
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2017, 18 (05) : 366 - 373
  • [49] Speckle tracking echocardiography in severe patient-prosthesis mismatch
    Osken, Altug
    Dayi, Sennur Unal
    Ozcan, Kazim Serhan
    Keskin, Muhammed
    Oz, Tugba Kemaloglu
    Poyraz, Esra
    Gurkan, Ufuk
    Akgoz, Haldun
    Cam, Nese
    HERZ, 2021, 46 (04) : 375 - 380
  • [50] Left ventricular mass regression in patients without patient–prosthesis mismatch after aortic valve replacement for aortic stenosis
    Kohei Hachiro
    Takeshi Kinoshita
    Tohru Asai
    Tomoaki Suzuki
    General Thoracic and Cardiovascular Surgery, 2020, 68 : 227 - 232