Patient-prosthesis mismatch does not affect survival following aortic valve replacement

被引:70
|
作者
Howell, Neil J. [1 ]
Keogh, Bruce E. [1 ]
Barnet, Vivien [1 ]
Bonser, Robert S. [1 ]
Graham, Timothy R. [1 ]
Rooney, Stephen J. [1 ]
Wilson, Ian C. [1 ]
Pagano, Domenico [1 ]
机构
[1] Univ Hosp NHS Fdn Trust, Dept Cardiothorac Surg, Birmingham, W Midlands, England
关键词
aortic valve disease; aortic valve replacement;
D O I
10.1016/j.ejcts.2006.03.046
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Patient-prosthesis mismatch (PPM) has been reported to increase perioperative mortality and reduce postoperative survival in patients undergoing aortic valve replacement (AVR). We analysed the effect of PPM at values predicting severe mismatch on survival following AVR in our unit. Methods: Prospectively collected data on 1481 consecutive patients who had undergone AVR with or without coronary artery revascularisation between 1997 and 2005 were analysed. Projected in vitro valve effective orifice area (EOA) and geometric prosthesis internal orifice area (GOA) were evaluated and values were indexed to body surface area (cm(2) m(-2)). PPM was defined as EOAi < 0.6 and/or GOAi < 1.1. Long-term survival data were obtained from the National Institute of Statistics. Results: One thousand four hundred and eighteen patients were identified. 67/1418 (4.7%) patients had GOAi < 1.1; 122/1418 (8.6%) had EOAi < 0.6 and 38 (2.6%) patients exhibited both forms of mismatch. One thousand two hundred and sixty-seven patients (89%) demonstrated no mismatch (reference group). There were 75 in-hospital deaths (overall mortality 5.3%) with no significant difference between the mismatch and the reference groups. Survival data were available for up to 8 years (median 36 months, IQR 6-60 months). There were 160 late deaths (13/143 PPM group vs 147/1198 reference group). The 5-year survival estimate was similar for both groups (83% PPM group; 81% reference group; p = 0.47). Cox-hazard analysis identified advanced age as the only predictor of reduced survival (age > 80, RR 2.13, 95% CI 1.38-4.586, p = 0.004). Conclusions: Severe patient-prosthesis mismatch was predicted in 4-10% of patients undergoing AVR but this did not affect in-hospital mortality or mid-term survival. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:10 / 14
页数:5
相关论文
共 50 条
  • [31] Prosthesis-patient mismatch after surgical aortic valve replacement in patients with aortic stenosis
    Kim, Hee Jung
    Kim, Ho Jin
    Kim, Joon Bum
    Jung, Sung-Ho
    Choo, Suk Jung
    Chung, Cheol Hyun
    Lee, Jae Won
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2020, 31 (02) : 152 - 157
  • [32] Aortic valve replacement and prosthesis-patient mismatch in the era of trans-catheter aortic valve implantation
    Shigeki Morita
    General Thoracic and Cardiovascular Surgery, 2016, 64 : 435 - 440
  • [33] Aortic valve replacement and prosthesis-patient mismatch in the era of trans-catheter aortic valve implantation
    Morita, Shigeki
    GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2016, 64 (08) : 435 - 440
  • [34] Imaging for Predicting and Assessing Prosthesis-Patient Mismatch After Aortic Valve Replacement
    Pibarot, Philippe
    Magne, Julien
    Leipsic, Jonathon
    Cote, Nancy
    Blanke, Philippe
    Thourani, Vinod H.
    Hahn, Rebecca
    JACC-CARDIOVASCULAR IMAGING, 2019, 12 (01) : 149 - 162
  • [35] Prosthesis-Patient Mismatch After "High-Risk" Aortic Valve Replacement
    Popma, Jeffrey J.
    Khabbaz, Kamal
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (13) : 1335 - 1338
  • [36] Aortic valve replacement for aortic stenosis in the elderly: Influence of prosthesis-patient mismatch on late survival and left ventricular mass regression
    Kato Y.
    Tsutsumi Y.
    Kawai T.
    Goto T.
    Takahashi Y.
    Ohashi H.
    General Thoracic and Cardiovascular Surgery, 2008, 56 (8) : 397 - 403
  • [37] Aortoventriculoplasty for Correction of Patient-Prosthesis Mismatch Examples
    Vural, Kerem M.
    Ozyalcin, Sertan
    Turkmen, Ufuk
    Bozkurt, Tezcan
    HEART LUNG AND CIRCULATION, 2014, 23 (03) : E96 - E99
  • [38] Perceval or Trifecta to Prevent Patient-Prosthesis Mismatch
    Hernandez-Vaquero, Daniel
    Vigil-Escalera, Carlota
    Persia, Yvan
    Morales, Carlos
    Pascual, Isaac
    Dominguez-Rodriguez, Alberto
    Rodriguez-Caulo, Emiliano
    Carnero, Manuel
    Diaz, Rocio
    Avanzas, Pablo
    Moris, Cesar
    Silva, Jacobo
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (09) : 1 - 11
  • [39] Patient-prosthesis mismatch in the mitral position affects midterm survival and functional status
    Bouchard, Denis
    Vanden Eynden, Frederic
    Demers, Philippe
    Perrault, Louis P.
    Carrier, Michel
    Cartier, Raymond
    Basmadjian, Arsene J.
    Pellerin, Michel
    CANADIAN JOURNAL OF CARDIOLOGY, 2010, 26 (10) : 532 - 536
  • [40] Prosthesis-patient mismatch following aortic and mitral valves replacement - A comprehensive review
    Joury, Abdulaziz
    Duran, Antonio
    Stewart, Merrill
    Gilliland, Yvonne E.
    Spindel, Stephen M.
    Qamruddin, Salima
    PROGRESS IN CARDIOVASCULAR DISEASES, 2022, 72 : 84 - 92