Patient-prosthesis mismatch does not affect survival following aortic valve replacement

被引:70
|
作者
Howell, Neil J. [1 ]
Keogh, Bruce E. [1 ]
Barnet, Vivien [1 ]
Bonser, Robert S. [1 ]
Graham, Timothy R. [1 ]
Rooney, Stephen J. [1 ]
Wilson, Ian C. [1 ]
Pagano, Domenico [1 ]
机构
[1] Univ Hosp NHS Fdn Trust, Dept Cardiothorac Surg, Birmingham, W Midlands, England
关键词
aortic valve disease; aortic valve replacement;
D O I
10.1016/j.ejcts.2006.03.046
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Patient-prosthesis mismatch (PPM) has been reported to increase perioperative mortality and reduce postoperative survival in patients undergoing aortic valve replacement (AVR). We analysed the effect of PPM at values predicting severe mismatch on survival following AVR in our unit. Methods: Prospectively collected data on 1481 consecutive patients who had undergone AVR with or without coronary artery revascularisation between 1997 and 2005 were analysed. Projected in vitro valve effective orifice area (EOA) and geometric prosthesis internal orifice area (GOA) were evaluated and values were indexed to body surface area (cm(2) m(-2)). PPM was defined as EOAi < 0.6 and/or GOAi < 1.1. Long-term survival data were obtained from the National Institute of Statistics. Results: One thousand four hundred and eighteen patients were identified. 67/1418 (4.7%) patients had GOAi < 1.1; 122/1418 (8.6%) had EOAi < 0.6 and 38 (2.6%) patients exhibited both forms of mismatch. One thousand two hundred and sixty-seven patients (89%) demonstrated no mismatch (reference group). There were 75 in-hospital deaths (overall mortality 5.3%) with no significant difference between the mismatch and the reference groups. Survival data were available for up to 8 years (median 36 months, IQR 6-60 months). There were 160 late deaths (13/143 PPM group vs 147/1198 reference group). The 5-year survival estimate was similar for both groups (83% PPM group; 81% reference group; p = 0.47). Cox-hazard analysis identified advanced age as the only predictor of reduced survival (age > 80, RR 2.13, 95% CI 1.38-4.586, p = 0.004). Conclusions: Severe patient-prosthesis mismatch was predicted in 4-10% of patients undergoing AVR but this did not affect in-hospital mortality or mid-term survival. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:10 / 14
页数:5
相关论文
共 50 条
  • [21] Stent valve implantation in conventional redo aortic valve surgery to prevent patient-prosthesis mismatch
    Ferrari, Enrico
    Franciosi, Giorgio
    Clivio, Sara
    Faletra, Francesco
    Moccetti, Marco
    Moccetti, Tiziano
    Pedrazzini, Giovanni
    Demertzis, Stefanos
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2017, 24 (03) : 319 - 323
  • [22] Prosthesis-patient mismatch after aortic valve replacement
    Dahou A.
    Mahjoub H.
    Pibarot P.
    Current Treatment Options in Cardiovascular Medicine, 2016, 18 (11)
  • [23] Patient-Prosthesis Mismatch
    Hernandez-Vaquero, Daniel
    Hardin, John
    Llosa, Juan C.
    ANNALS OF THORACIC SURGERY, 2012, 94 (06) : 2182 - 2183
  • [24] Patient-prosthesis mismatch and surgical aortic valve replacement outcomes: Retrospective analysis of single-center surgical data
    Gupta, Aurinjoy
    Aliter, Hashem
    Theriault, Chris
    Chedrawy, Edgar
    JOURNAL OF CARDIAC SURGERY, 2021, 36 (08) : 2805 - 2815
  • [25] Overcoming prosthesis-patient mismatch with transcatheter aortic valve replacement
    Grubb, Kendra J.
    Tom, Stephanie K.
    Sultan, Ibrahim
    Sa, Michel Pompeu
    ANNALS OF CARDIOTHORACIC SURGERY, 2024, 13 (03) : 236 - 243
  • [26] Patient-prosthesis mismatch following TAVR: time will tell
    Thourani, Vinod H.
    Holst, Kimberly A.
    EUROINTERVENTION, 2023, 19 (09) : 707 - 707
  • [27] Reducing Prosthesis-Patient Mismatch With Edwards Magna Prosthesis for Aortic Valve Replacement
    Kume, Yuta
    Fujita, Tomoyuki
    Fukushima, Satsuki
    Hata, Hiroki
    Shimahara, Yusuke
    Matsumoto, Yorihiko
    Yamashita, Kizuku
    Kobayashi, Junjiro
    CIRCULATION JOURNAL, 2017, 81 (04) : 468 - 475
  • [28] Patient prosthesis mismatch after aortic valve replacement: An Indian perspective
    Joshi, Shreedhar S.
    Ashwini, T.
    George, Antony
    Jagadeesh, A. M.
    ANNALS OF CARDIAC ANAESTHESIA, 2016, 19 (01) : 84 - 88
  • [29] Implications of valve prosthesis-patient mismatch in patients undergoing aortic valve replacement; who tolerates and who does not?
    Pai R.K.
    Lad V.
    Agarwal N.
    Khandeparkar J.
    Patwardhan A.
    Indian Journal of Thoracic and Cardiovascular Surgery, 2005, 21 (4) : 256 - 261
  • [30] Predictors and Outcomes of Prosthesis-Patient Mismatch After Aortic Valve Replacement
    Dayan, Victor
    Vignolo, Gustavo
    Soca, Gerardo
    Paganini, Juan Jose
    Brusich, Daniel
    Pibarot, Philippe
    JACC-CARDIOVASCULAR IMAGING, 2016, 9 (08) : 924 - 933