摘要
Objective: Patient-prosthesis mismatch (PPM) has been reported to increase perioperative mortality and reduce postoperative survival in patients undergoing aortic valve replacement (AVR). We analysed the effect of PPM at values predicting severe mismatch on survival following AVR in our unit. Methods: Prospectively collected data on 1481 consecutive patients who had undergone AVR with or without coronary artery revascularisation between 1997 and 2005 were analysed. Projected in vitro valve effective orifice area (EOA) and geometric prosthesis internal orifice area (GOA) were evaluated and values were indexed to body surface area (cm(2) m(-2)). PPM was defined as EOAi < 0.6 and/or GOAi < 1.1. Long-term survival data were obtained from the National Institute of Statistics. Results: One thousand four hundred and eighteen patients were identified. 67/1418 (4.7%) patients had GOAi < 1.1; 122/1418 (8.6%) had EOAi < 0.6 and 38 (2.6%) patients exhibited both forms of mismatch. One thousand two hundred and sixty-seven patients (89%) demonstrated no mismatch (reference group). There were 75 in-hospital deaths (overall mortality 5.3%) with no significant difference between the mismatch and the reference groups. Survival data were available for up to 8 years (median 36 months, IQR 6-60 months). There were 160 late deaths (13/143 PPM group vs 147/1198 reference group). The 5-year survival estimate was similar for both groups (83% PPM group; 81% reference group; p = 0.47). Cox-hazard analysis identified advanced age as the only predictor of reduced survival (age > 80, RR 2.13, 95% CI 1.38-4.586, p = 0.004). Conclusions: Severe patient-prosthesis mismatch was predicted in 4-10% of patients undergoing AVR but this did not affect in-hospital mortality or mid-term survival. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:10 / 14
页数:5
相关论文
共 50 条
  • [11] Surgical versus transcatheter aortic valve replacement: Impact of patient-prosthesis mismatch on outcomes
    Alnajar, Ahmed
    Hamad, Naser
    Azhar, Muhammad Z.
    Mousa, Yaseen
    Arora, Yingyot
    Lamelas, Joseph
    JOURNAL OF CARDIAC SURGERY, 2022, 37 (12) : 5388 - 5394
  • [12] Novel Thoughts on Patient-Prosthesis Mismatch in Aortic Valve Replacement: The Rationale for the PAR I Trial
    Doenst, Torsten
    Amorim, Paulo A.
    Diab, Mahmoud
    Hagendorff, Andreas
    Faerber, Gloria
    Graff, Juergen
    Rastan, Ardawan
    Deutsch, Oliver
    Eichinger, Walter
    THORACIC AND CARDIOVASCULAR SURGEON, 2014, 62 (06) : 463 - 468
  • [13] Myocardial metabolism and diastolic function after aortic valve replacement for aortic stenosis: influence of patient-prosthesis mismatch
    Mannacio, Vito
    Di Tommaso, Luigi
    Stassano, Paolo
    De Amicis, Vincenzo
    Vosa, Carlo
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2012, 41 (02) : 316 - 321
  • [14] Prosthesis-patient mismatch in transcatheter aortic valve replacement
    Grubb, Kendra J.
    Kalra, Kanika
    Tom, Stephanie K.
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2025, 72 : 31 - 33
  • [15] Con: Patient-Prosthesis Mismatch Now Is Not an Important Consideration in the Majority of Patients After Aortic Valve Replacement
    Vernick, William J.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2014, 28 (01) : 184 - 188
  • [16] Is Patient-Prosthesis Mismatch a Perioperative Predictor of Long-Term Mortality After Aortic Valve Replacement?
    Carlos Bianco, Juan
    Qizilbash, Baqir
    Carrier, Michel
    Couture, Pierre
    Fortier, Annik
    Tardif, Jean-Claude
    Lambert, Jean
    Denault, Andre Y.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2013, 27 (04) : 647 - 653
  • [17] Surgical aortic valve replacement and patient-prosthesis mismatch: a meta-analysis of 108 182 patients
    Barros de Oliveira Sa, Michel Pompeu
    Barros de Carvalho, Martinha Millianny
    Sobral Filho, Dario Celestino
    Pereira Cavalcanti, Luiz Rafael
    Rayol, Sergio da Costa
    Silva Diniz, Roberto Gouvea
    Menezes, Alexandre Motta
    Clavel, Marie-Annick
    Pibarot, Philippe
    Lima, Ricardo Carvalho
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2019, 56 (01) : 44 - 54
  • [18] Early outcome of aortic valve replacement with mechanical prosthesis in patients with aortic stenosis. Is patient-prosthesis mismatch a significant, clinical problem?
    Jander, Slawomir
    Bitner, Miroslaw
    Jegier, Bogdan
    Ostrowski, Stanislaw
    Jaszewski, Ryszard
    ARCHIVES OF MEDICAL SCIENCE, 2007, 3 (01) : 57 - 60
  • [19] Left ventricular mass regression in patients without patient-prosthesis mismatch after aortic valve replacement for aortic stenosis
    Hachiro, Kohei
    Kinoshita, Takeshi
    Asai, Tohru
    Suzuki, Tomoaki
    GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2020, 68 (03) : 227 - 232
  • [20] Patient and procedure selection for the prevention of prosthesis-patient mismatch following aortic valve replacement
    Pibarot, Philippe
    Clavel, Marie-Annick
    Dahou, Abdellaziz
    EUROINTERVENTION, 2015, 11 : W106 - W109