Imaging characteristics of a CsI:Tl slot detector for digital mammography

被引:0
|
作者
Jing, Z
Huda, W
Walker, JK
机构
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:101 / 101
页数:1
相关论文
共 50 条
  • [1] Performance of a CsI:Tl screen based scanning slot detector for digital mammography
    Jing, ZX
    Huda, W
    Walker, JK
    Choi, WY
    PHYSICS OF MEDICAL IMAGING - MEDICAL IMAGING 1997, 1997, 3032 : 275 - 281
  • [2] Detective quantum efficiency of a CsI:Tl scintillator based scanning slot x-ray detector for digital mammography
    Jing, ZX
    Huda, W
    Walker, JK
    Choi, WY
    PHYSICS OF MEDICAL IMAGING, 1998, 3336 : 583 - 591
  • [3] New design of a structured CsI(Tl) screen for digital mammography
    Nagarkar, VV
    Tipnis, SV
    Gaysinskiy, VB
    Miller, SR
    Karellas, A
    Vedantham, S
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 541 - 546
  • [4] Spatial frequency dependent DQE performance of a CsI:Tl based X-ray detector for digital mammography
    Jing, ZX
    Huda, W
    Walker, JK
    Choi, WY
    MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 159 - 168
  • [5] Design considerations of a slot scintillation detector for digital mammography
    Jing, JX
    Huda, W
    Walker, JK
    Choi, WY
    DIGITAL MAMMOGRAPHY '96, 1996, 1119 : 151 - 154
  • [6] A CdZnTe slot-scanned detector for digital mammography
    Mainprize, JG
    Ford, NL
    Yin, S
    Gordon, EE
    Hamilton, WJ
    Tümer, TO
    Yaffe, MJ
    MEDICAL PHYSICS, 2002, 29 (12) : 2767 - 2781
  • [7] Characteristics of a CsI(Tl) Compton-suppressed clover detector
    Zhang, N. T.
    Lei, X. G.
    Guo, Y. X.
    Zhou, X. H.
    Zhang, Y. H.
    Ma, F.
    Li, S. C.
    Liu, M. L.
    Zheng, Y.
    Fang, Y. D.
    Hua, W.
    Guo, S.
    Qiang, Y. H.
    Wang, J. G.
    Gao, B. S.
    Xu, S. W.
    Chen, S. Z.
    JOURNAL OF PHYSICS G-NUCLEAR AND PARTICLE PHYSICS, 2013, 40 (03)
  • [8] Spectral response of CsI(Tl) transparent scintillation detector for megavoltage imaging
    Samant, SS
    Zeman, H
    Weinberg, BD
    Zheng, W
    Patra, P
    MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 793 - 805
  • [9] Gamma-ray imaging with a Si/CsI(Tl) compton detector
    Hoover, A. S.
    Sullivan, J. P.
    Baird, B.
    Brumby, S. P.
    Kippen, R. M.
    McCluskey, C. W.
    Rawool-Sullivan, M. W.
    Sorensen, E. B.
    APPLIED RADIATION AND ISOTOPES, 2006, 64 (12) : 1648 - 1654
  • [10] The CsI(Tl) calorimeter of the BaBar detector
    Bauer, JM
    PROCEEDINGS OF THE SEVENTH INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS, 1998, : 72 - 81