摘要
Capillary columns used for nanoflow liquid chromatography play an important role in modern proteomics. High quality columns are needed to provide high peak capacity and highly reproducible separations. This is extremely important when multiple separations were compared in parallel in searching for potential biomarkers. Herein, we introduce a "plug-and-use" fritting technology for fabrication of high quality and highly reproducible capillary columns. Due to the identical length, good permeability, and stability of the prefabricated frits adopted, the capillary columns presented excellent performance consistency in terms of retention time, peak width as well as peak capacity at a column-to-column level (relative standard deviations, RSDs, at 0.4-0.9%, 2.1-3.6%, and 2.7%, respectively, n = 6) for separations of complex mixtures of protein digest. For capillary columns packed with 5 mu m particles, high separation efficiency was demonstrated by the minimum plate height of 11 p.m, approaching the theoretical performance limit of such material. For separations of protein digests, the columns demonstrated excellent peak capacities of 110 and 300 for 20 and 360 min gradients, respectively. The simple fabrication, good performance as well as consistent quality of such columns provide a reliable tool for high throughput separations requiring the use of multiple high performance capillary columns in parallel. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:109 / 114
页数:6
相关论文
共 50 条
  • [1] Towards high peak capacity separations in normal pressure nanoflow liquid chromatography using meter long packed capillary columns
    Han, Jing
    Ye, Linquan
    Xu, Lingjia
    Zhou, Zhuoheng
    Gao, Fan
    Xiao, Zhiliang
    Wang, Qiuquan
    Zhang, Bo
    ANALYTICA CHIMICA ACTA, 2014, 852 : 267 - 273
  • [2] Performance and lifetime of slurry packed capillary columns for high performance liquid chromatography
    Franc, Martin
    Vojta, Jiri
    Sobotnikova, Jana
    Coufal, Pavel
    Bosakova, Zuzana
    CHEMICAL PAPERS, 2014, 68 (01) : 22 - 28
  • [3] Intact-protein trapping columns for proteomic analysis in capillary high-performance liquid chromatography
    Guan, Xia
    Yan, Guoquan
    Gao, Mingxia
    Hong, Guangfeng
    Deng, Chunhui
    Zhang, Xiangmin
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (44) : 6875 - 6881
  • [4] Nanoflow gradient generator for capillary high-performance liquid chromatography-nanoelectrospray mass spectrometry
    Ito, S
    Yoshioka, S
    Ogata, I
    Takeda, A
    Yamashita, E
    Deguchi, K
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1051 (1-2) : 19 - 23
  • [5] Towards a high peak capacity of 130 using nanoflow hydrophilic interaction liquid chromatography
    Liu, Ya
    Wang, Xiaofei
    Chen, Zhangqian
    Liang, Derek Hecheng
    Sun, Kaiyue
    Huang, Shanqing
    Zhu, Jue
    Shi, Xiaohui
    Zeng, Juxing
    Wang, Qiuquan
    Zhang, Bo
    ANALYTICA CHIMICA ACTA, 2019, 1062 : 147 - 155
  • [6] A protocol for fabrication of polymer monolithic capillary columns and tuning the morphology targeting high-resolution bioanalysis in gradient-elution liquid chromatography
    Zhou, Zhuoheng
    Hilder, Emily F.
    Eeltink, Sebastiaan
    JOURNAL OF SEPARATION SCIENCE, 2023, 46 (18)
  • [7] Surfactant-bound monolithic columns for separation of proteins in capillary high performance liquid chromatography
    Gu, Congying
    He, Jun
    Jia, Jinping
    Fang, Nenghu
    Simmons, Robert
    Shamsi, Shahab A.
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (04) : 530 - 539
  • [8] Polyethylenimine-modified metal oxides for fabrication of packed capillary columns for capillary electrochromatography and capillary liquid chromatography
    Wiedmer, Susanne K.
    D'Orazio, Giovanni
    Smatt, Jan-Henrik
    Bourdin, Delphine
    Banos-Perez, Clara
    Sakeye, Motolani
    Kivilompolo, Maarit
    Kopperi, Matias
    Ruiz-Jimenez, Jose
    Fanali, Salvatore
    Riekkola, Marja-Liisa
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (30) : 5020 - 5029
  • [9] Application of porous layer open tubular capillary columns with narrow inner diameter in nanoflow-high performance liquid chromatography for N-derivatized amino acid enantiomers
    Li Ruonan
    Wang Lijuan
    Zhang Dongtang
    Wang Yanan
    Guo Guangsheng
    Wang Xiayan
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2020, 38 (03) : 350 - 355
  • [10] Photopolymerized organo-silica hybrid monolithic columns: Characterization of their performance in capillary liquid chromatography
    Weed, Anna-Marie Karen
    Dvornik, Jill
    Stefancin, John Jacob
    Gyapong, Afua Asantewaa
    Svec, Frantisek
    Zajickova, Zuzana
    JOURNAL OF SEPARATION SCIENCE, 2013, 36 (02) : 270 - 278