Experimental results and thermodynamic analysis of a natural gas small scale cogeneration plant for power and refrigeration purposes

被引:9
作者
Bazzo, Edson [1 ]
de Carvalho, Alvaro Nacif [1 ]
Matelli, Jose Alexandre [2 ]
机构
[1] UFSC Fed Univ Santa Catarina, Dept Mech Engn, BR-88040900 Florianopolis, SC, Brazil
[2] UNESP Univ Estadual Paulista, Dept Energy, BR-12516410 Guaratingueta, SP, Brazil
关键词
Cogeneration; Microturbine; Absorption chiller; Natural gas; EUROPEAN PERSPECTIVE; COMBINED HEAT; SYSTEM; ENERGY; MICROTURBINE; PERFORMANCE;
D O I
10.1016/j.applthermaleng.2013.04.041
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this work, experimental results are reported for a small scale cogeneration plant for power and refrigeration purposes. The plant includes a natural gas microturbine and an ammonia/water absorption chiller fired by steam. The system was tested under different turbine loads, steam pressures and chiller outlet temperatures. An evaluation based on the 1st and 2nd Laws of Thermodynamics was also performed. For the ambient temperature around 24 degrees C and microturbine at full load, the plant is able to provide 19 kW of saturated steam at 5.3 bar (161 degrees C), corresponding to 9.2 kW of refrigeration at -5 degrees C (COP = 0.44). From a 2nd law point-of-view, it was found that there is an optimal chiller outlet temperature that maximizes the chiller exergetic efficiency. As expected, the microturbine presented the highest irreversibilities, followed by the absorption chiller and the HRSG. In order to reduce the plant exergy destruction, it is recommended a new design for the HRSG and a new insulation for the exhaust pipe. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:264 / 272
页数:9
相关论文
共 19 条
[1]  
Bejan A, 1996, THERMAL DESIGN OPTIM
[2]   Experimentation on a cogenerative system based on a microturbine [J].
Colombo, Luigi P. M. ;
Armanasco, Fabio ;
Perego, Omar .
APPLIED THERMAL ENGINEERING, 2007, 27 (04) :705-711
[3]   Study and control of the optimal generation temperature in NH3-H2O absorption refrigeration systems [J].
Fernández-Seara, J ;
Vázquez, M .
APPLIED THERMAL ENGINEERING, 2001, 21 (03) :343-357
[4]   Solar-powered systems for cooling, dehumidification and air-conditioning [J].
Grossman, G .
SOLAR ENERGY, 2002, 72 (01) :53-62
[5]   Performance study of a microturbine system for cogeneration application [J].
Ho, JC ;
Chua, KJ ;
Chou, SK .
RENEWABLE ENERGY, 2004, 29 (07) :1121-1133
[6]   Experimental investigation of a vapor absorption refrigeration system [J].
Horuz, I ;
Callander, TMS .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (01) :10-16
[7]  
Izquierdo M., 2009, P ECOS 2009 FOZ DO I
[8]   Thermodynamic analysis of the absorption refrigeration system with geothermal energy:: an experimental study [J].
Keçeciler, A ;
Acar, HI ;
Dogan, A .
ENERGY CONVERSION AND MANAGEMENT, 2000, 41 (01) :37-48
[9]  
Kotas TJ., 1995, The exergy method of thermal plant analysis
[10]   Application of combined heat-and-power and absorption cooling in a supermarket [J].
Maidment, GG ;
Zhao, X ;
Riffat, SB ;
Prosser, G .
APPLIED ENERGY, 1999, 63 (03) :169-190