Fast Accurate MR Thermometry Using Phase Referenced Asymmetric Spin-Echo EPI at High Field

被引:15
作者
Streicher, Markus N. [1 ]
Schaefer, Andreas [1 ]
Ivanov, Dimo [1 ]
Mueller, Dirk K. [1 ]
Amadon, Alexis [1 ]
Reimer, Enrico [1 ]
Huber, Laurentius [1 ]
Dhital, Bibek [1 ]
Rivera, Debra [1 ]
Koegler, Carsten [1 ]
Trampel, Robert [1 ]
Pampel, Andre [1 ]
Turner, Robert [1 ]
机构
[1] Max Planck Inst Human Cognit & Brain Sci, D-04103 Leipzig, Germany
关键词
referenced; MR thermometry; fat; spin-echo; asymmetric; proton resonance frequency shift; PRF SHIFT THERMOMETRY; CHEMICAL-SHIFT; MAGNETIC-FIELD; STEADY-STATE; TEMPERATURE; SUSCEPTIBILITY; NMR; FAT; RESPIRATION; TISSUE;
D O I
10.1002/mrm.24681
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeA novel highly accurate method for MR thermometry, effective at high field, is introduced and validated, which corrects for slow and fast field fluctuations by means of reference images. MethodsAn asymmetric spin-echo echo planar imaging sequence was made frequency-selective to water or a reference substance by controlling the slice-select gradient polarity and the duration of the excitation and refocusing radiofrequency pulses. Images were acquired pairwise, and the temperature-sensitive water images were corrected for field fluctuations using the reference images. In a phantom radiofrequency heating experiment, dissolved dimethyl sulfoxide was used as a reference substance. Temperature stability was tested in vivo on the human brain, referenced using subcutaneous scalp fat. Water and fat phase images were acquired only 50 ms apart. Bloch simulations validated the frequency selection accuracy. ResultsAsymmetric spin-echo imaging using a simple frequency selection method provides highly accurate referenced MR thermometry in phantoms and in vivo at 7 T. Effects of field fluctuations caused by field drift, breathing, and heart beat were corrected. The technique is highly robust against B-1 inhomogeneities. ConclusionFrequency selection using gradient-reversal can enable fast accurate referenced in vivo MR thermometry, assisting thermal characterization of radiofrequency coils and possibly in vivo SAR monitoring. Magn Reson Med 71:524-533, 2014. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:524 / 533
页数:10
相关论文
共 50 条
  • [1] A method for simulation of NOESY, ROESY, and off-resonance ROESY spectra
    Allard, P
    Helgstrand, M
    Härd, T
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1997, 129 (01) : 19 - 29
  • [2] Amadon A, 2008, P 16 ANN M ISMRM TOR, P1248
  • [3] [Anonymous], 2009, Introduction to Functional magnetic resonance imaging
  • [4] RECONSTRUCTIONS OF PHASE-CONTRAST, PHASED-ARRAY MULTICOIL DATA
    BERNSTEIN, MA
    GRGIC, M
    BROSNAN, TJ
    PELC, NJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) : 330 - 334
  • [5] Cao Z, 2012, ISMRM SCI WORKSH MR
  • [6] Radiofrequency power deposition utilizing thermal imaging
    Cline, H
    Mallozzi, R
    Li, Z
    McKinnon, G
    Barber, W
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (06) : 1129 - 1137
  • [7] Temperature and SAR calculations for a human head within volume and surface coils at 64 and 300 MHz
    Collins, CM
    Liu, WZ
    Wang, JH
    Gruetter, R
    Vaughan, JT
    Ugurbil, K
    Smith, MB
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (05) : 650 - 656
  • [8] Model of local temperature changes in brain upon functional activation
    Collins, CM
    Smith, MB
    Turner, R
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2004, 97 (06) : 2051 - 2055
  • [9] Specific Absorption Rate Intersubject Variability in 7T Parallel Transmit MRI of the Head
    de Greef, Martijn
    Ipek, Ozlem
    Raaijmakers, Alexander J. E.
    Crezee, Johannes
    van den Berg, Cornelis A. T.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (05) : 1476 - 1485
  • [10] Motion Correction in MR Thermometry of Abdominal Organs: a Comparison of the Referenceless vs. the Multibaseline Approach
    de Senneville, Baudouin Denis
    Roujol, Sebastien
    Moonen, Chrit
    Ries, Mario
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (05) : 1373 - 1381