A Medium-Format, Mixed-Mode Pixel Array Detector for Kilohertz X-ray Imaging

被引:38
作者
Tate, M. W. [1 ]
Chamberlain, D. [2 ]
Green, K. S. [1 ,2 ]
Philipp, H. T. [1 ]
Purohit, P. [1 ]
Strohman, C. [3 ]
Gruner, S. M. [1 ,2 ,3 ,4 ]
机构
[1] Cornell Univ, Atom & Solid State Phys Lab, Ithaca, NY 14853 USA
[2] Cornell Univ, Cornell High Energy Synchrotron Source, Ithaca, NY 14853 USA
[3] Cornell Lab Accelerator based Sci & Educ, Ithaca, NY 14853 USA
[4] Cornell Univ, Kavli Inst Cornell Nanoscale Sci, Ithaca, NY 14853 USA
来源
11TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI 2012) | 2013年 / 425卷
关键词
D O I
10.1088/1742-6596/425/6/062004
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An x-ray pixel array detector (PAD) capable of framing up to 1 kHz is described. This hybrid detector is constructed from a 3-side buttable, 128x128 pixel module based upon the mixed-mode pixel array detector (MMPAD) chip developed jointly by Cornell and Area Detector Systems Corporation (Poway, CA). The chip uses a charge integrating front end for a high instantaneous count rate yet with single photon sensitivity. In-pixel circuitry utilizing a digital overflow counter extends the per frame dynamic range to >4x10(7) x-rays/pixel. Results are shown from a base configuration of a 2x3 module array (256x384 pixels).
引用
收藏
页数:4
相关论文
共 11 条
  • [1] The medipix3 prototype, a pixel readout chip working in single photon counting mode with improved spectrometric performance
    Ballabriga, R.
    Campbell, M.
    Heijne, E. H. M.
    Llopart, X.
    Tlustos, L.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (05) : 1824 - 1829
  • [2] Green K S, 2012, SRI 2012 C P
  • [3] The adaptive gain integrating pixel detector AGIPD a detector for the European XFEL
    Henrich, B.
    Becker, J.
    Dinapoli, R.
    Goettlicher, P.
    Graafsma, H.
    Hirsemann, H.
    Klanner, R.
    Krueger, H.
    Mazzocco, R.
    Mozzanica, A.
    Perrey, H.
    Potdevin, G.
    Schmitt, B.
    Shi, X.
    Srivastava, A. K.
    Trunk, U.
    Youngman, C.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 633 : S11 - S14
  • [4] PILATUS: A single photon counting pixel detector for X-ray applications
    Henrich, B.
    Bergamaschi, A.
    Broennimann, C.
    Dinapoli, R.
    Eikenberry, E. F.
    Johnson, I.
    Kobas, M.
    Kraft, P.
    Mozzanica, A.
    Schmitt, B.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (01) : 247 - 249
  • [5] X-ray analog pixel array detector for single synchrotron bunch time-resolved imaging
    Koerner, Lucas J.
    Gruner, Sol M.
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2011, 18 : 157 - 164
  • [6] Solving structure with sparse, randomly-oriented x-ray data
    Philipp, Hugh T.
    Ayyer, Kartik
    Tate, Mark W.
    Elser, Veit
    Gruner, Sol M.
    [J]. OPTICS EXPRESS, 2012, 20 (12): : 13129 - 13137
  • [7] Low-flux measurements with Cornell's LCLS integrating pixel array detector
    Philipp, Hugh T.
    Tate, Mark W.
    Gruner, Sol M.
    [J]. JOURNAL OF INSTRUMENTATION, 2011, 6
  • [8] Pixel array detector for X-ray free electron laser experiments
    Philipp, Hugh T.
    Hromalik, Marianne
    Tate, Mark
    Koerner, Lucas
    Gruner, Sol M.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 649 (01) : 67 - 69
  • [9] Tests of a prototype pixel array detector for microsecond time-resolved X-ray diffraction
    Rossi, G
    Renzi, M
    Eikenberry, EF
    Tate, MW
    Bilderback, D
    Fontes, E
    Wixted, R
    Barna, S
    Gruner, SM
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 1999, 6 : 1096 - 1105
  • [10] Schuette D.R., 2008, THESIS