Sensor fault detection and isolation in a thermal power plant steam separator

被引:13
作者
Shashoa, Nasar Aldian Ambark [1 ]
Kvascev, Goran [1 ]
Marjanovic, Aleksandra [1 ]
Djurovic, Zeljko [1 ]
机构
[1] Univ Belgrade, Sch Elect Engn, Signal & Syst Dept, Belgrade 11000, Serbia
关键词
Fault detection and isolation algorithms; Steam separators; Systems identification; Neyman-Pearson test; DIAGNOSIS;
D O I
10.1016/j.conengprac.2013.02.012
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A fault detection and isolation approach, specially designed for steam separators in thermal power plants, is presented in the paper. The first step of the proposed algorithm is to identify the process. Because of the presence of sporadic high-intensity measurement noise (outliers), the paper proposes a robust version of recursive identification. Starting from the parameter vector of the identified model, the second step of the proposed procedure has the form of a data-driven fault detector. This particular fault detection and isolation approach was implemented at TEKOB1 Kostolac Thermal Power Plant in Serbia, whose nominal power output is 330 MW. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:908 / 916
页数:9
相关论文
共 38 条
[1]  
Aitouche A., 2008, INT J SCI TECHNIQUES, V2, P764
[2]   NEW LOOK AT STATISTICAL-MODEL IDENTIFICATION [J].
AKAIKE, H .
IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 1974, AC19 (06) :716-723
[3]  
[Anonymous], 2002, Model selection and multimodel inference: a practical informationtheoretic approach
[4]  
[Anonymous], 2003, IFAC P, DOI [10.1016/S1474-6670(17)36468-6, DOI 10.1016/S1474-6670(17)36468-6]
[5]  
[Anonymous], 1999, SYSTEM IDENTIFICATIO
[6]  
[Anonymous], IFAC S ON LIN FAULT
[7]  
[Anonymous], CONTROL THEORY AD TE
[8]  
Barnet V., 1978, OUTLIERS STOCHASTIC
[9]  
Basseville M. E., 1993, DETECTION ABRUPT CHA, V15
[10]  
Bread R., 1971, MVT711 MIT