A large, high performance, curved 2D position-sensitive neutron detector

被引:23
|
作者
Fried, J [1 ]
Harder, JA [1 ]
Mahler, GJ [1 ]
Makowiecki, DS [1 ]
Mead, JA [1 ]
Radeka, V [1 ]
Schaknowski, NA [1 ]
Smith, GC [1 ]
Yu, B [1 ]
机构
[1] Brookhaven Natl Lab, Instrumentat Div, Upton, NY 11973 USA
关键词
neutron detector; position sensitive; interpolating readout; protein crystallography; MWPC;
D O I
10.1016/S0168-9002(01)01787-9
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new position-sensitive neutron detector has been designed and constructed for a protein crystallography station at LANL's pulsed neutron source. This station will be one of the most advanced instruments at a major neutron user facility for protein crystallography, fiber and membrane diffraction. The detector, based on neutron absorption in (3)He, has a large sensitive area of 3000 cm 2, angular coverage of 120degrees, timing resolution of 1 mus, rate capability in excess of 10(6) s(-1), position resolution of about 1.5 mm FWHM, and efficiency > 50% for neutrons of interest in the range 1-10 Angstrom. Features that are key to these remarkable specifications are the utilization of eight independently operating segments within a single gas volume, fabrication of the detector vessel and internal segments with a radius of curvature of about 70 cm, optimized position readout based on charge division and signal shaping with gated baseline restoration, and engineering design with high-strength aluminum alloy. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:415 / 419
页数:5
相关论文
共 50 条
  • [11] CONCEPT OF A NEW 2D POSITION-SENSITIVE SEMICONDUCTOR PIXEL DETECTOR
    WINKLER, W
    EHWALD, KE
    MEHR, W
    LANGE, W
    NOWAK, WD
    TRUTZSCHLER, K
    ECFA STUDY WEEK ON INSTRUMENTATION TECHNOLOGY FOR HIGH-LUMINOSITY HADRON COLLIDERS, PROCEEDINGS VOLS 1-2, 1989, 89 : 349 - 350
  • [12] POSITION ESTIMATION AND ERROR CORRECTION IN A 2D POSITION-SENSITIVE NAI(TL) DETECTOR
    KINAHAN, PE
    KARP, JS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 299 (1-3): : 484 - 489
  • [13] DESIGN AND PRELIMINARY TEST OF A LARGE AREA POSITION-SENSITIVE NEUTRON DETECTOR
    BERLINER, R
    MILDNER, DFR
    BRUGGER, RM
    KING, JS
    WERNER, SA
    YELON, WB
    PRINGLE, A
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1978, 23 (03): : 391 - 392
  • [14] A POSITION-SENSITIVE DETECTOR FOR NEUTRON POWDER DIFFRACTION
    TOMPSON, CW
    MILDNER, DFR
    MEHREGANY, M
    SUDOL, J
    BERLINER, R
    YELON, WB
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1984, 17 (DEC) : 385 - 394
  • [15] DEVELOPMENT OF A LINEAR POSITION-SENSITIVE NEUTRON DETECTOR
    SCHELTEN, J
    KURZ, R
    NADAY, I
    SCHAFER, W
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 205 (1-2): : 319 - 330
  • [16] Study of a position-sensitive scintillator neutron detector
    唐彬
    孙志嘉
    张强
    杨振
    许虹
    杨桂安
    王艳凤
    吴冲
    陈元柏
    杨雷
    Chinese Physics C, 2012, 36 (11) : 1089 - 1094
  • [17] A NEUTRON DIFFRACTOMETER WITH A LINEAR POSITION-SENSITIVE DETECTOR
    PARANJPE, SK
    DANDE, YD
    PRAMANA, 1989, 32 (06) : 793 - 800
  • [18] Study of a position-sensitive scintillator neutron detector
    Tang Bin
    Sun Zhi-Jia
    Zhang Qiang
    Yang Zhen
    Xu Hong
    Yang Gui-An
    Wang Yan-Feng
    Wu Chong
    Chen Yuan-Bo
    Yang Lei
    CHINESE PHYSICS C, 2012, 36 (11) : 1089 - 1094
  • [19] LINEAR MULTIANODE POSITION-SENSITIVE NEUTRON DETECTOR
    PATRA, AK
    CHINCHANIKAR, SR
    JOSHI, JN
    DANDE, YD
    UDYAVAR, RS
    DESAI, SS
    KOTHARE, RS
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 1993, 31 (06) : 418 - 420
  • [20] POSITION-SENSITIVE THERMAL-NEUTRON DETECTOR
    MUMINOV, RA
    TSVANG, LD
    SOVIET ATOMIC ENERGY, 1985, 58 (05): : 439 - 442