Intraoperative Doppler assessment of gastric tube perfusion in esophagogastroplasty

被引:15
作者
Tsekov, C
Belyaev, O
Tcholakov, O
Tcherveniakov, A
机构
[1] Ruhr Univ Bochum, St Josef Hosp, Dept Surg, D-44791 Bochum, Germany
[2] Pirogov Emergency Med Inst, Dept Gen & Thorac Surg, Sofia, Bulgaria
关键词
Doppler ultrasonography; intraoperative angiography; gastric mobilization; esophagogastric anastomosis;
D O I
10.1016/j.jss.2005.07.037
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background. Intraoperative Doppler ultrasonography is a non-invasive method with a great potential for the assessment of perfusion in surgery. This study aimed to determine the accuracy of Doppler ultrasonography in the assessment of blood flow on the top of an Akiyama-fashioned stomach tube for esophagus substitution. A secondary point of interest was the real length gained after construction of the gastric tube. Materials and methods. The Ivor-Lewis two stage gastro-esophagectomy was performed in 22 patients with carcinoma of the lower third of the esophagus. Vascularization of the gastric tube was assessed in every patient by Doppler sonographies after every separate step of stomach mobilization. Control arteriographies were performed at 4 major steps of mobilization to evaluate the accuracy of Doppler measurements. Results. Doppler assessment showed a sensitivity of 50 to 95%, specificity of up to 97% and overall accuracy between 95% and 75% during the separate steps of construction of the gastric tube. An approximate length of 4 cm was gained after the final mobilization and tubularization of the stomach. Conclusion. Our clinical trial revealed an excellent agreement between the results of Doppler sonography and arteriography. Doppler sonography proved to be a precise technique for the evaluation of stomach perfusion, especially for the needs of tissue viability assessment of the stomach tube in esophageal surgery. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:98 / 103
页数:6
相关论文
共 12 条
[1]   THORACOABDOMINAL APPROACH FOR CARCINOMA OF THE CARDIA OF THE STOMACH [J].
AKIYAMA, H ;
MIYAZONO, H ;
TSURUMARU, M ;
HASHIMOTO, C ;
KAWAMURA, T .
AMERICAN JOURNAL OF SURGERY, 1979, 137 (03) :345-349
[2]  
BARSOTTI J, 1972, NOUV PRESSE MED, V11, P2677
[3]  
BOUDIN G, 1977, NOUV PRESSE MED, V6, P2423
[4]   INTRA-OPERATIVE DETERMINATION OF SMALL INTESTINAL VIABILITY FOLLOWING ISCHEMIC-INJURY - A PROSPECTIVE, CONTROLLED TRIAL OF 2 ADJUVANT METHODS (DOPPLER AND FLUORESCEIN) COMPARED WITH STANDARD CLINICAL JUDGMENT [J].
BULKLEY, GB ;
ZUIDEMA, GD ;
HAMILTON, SR ;
OMARA, C ;
KLACSMANN, PG ;
HORN, SD .
ANNALS OF SURGERY, 1981, 193 (05) :628-637
[5]   DETERMINATION OF INTESTINAL VIABILITY BY DOPPLER ULTRASONOGRAPHY IN VENOUS INFARCTION [J].
COOPERMAN, M ;
MARTIN, EW ;
CAREY, LC .
ANNALS OF SURGERY, 1980, 191 (01) :57-58
[6]   USE OF DOPPLER ULTRASOUND IN INTESTINAL SURGERY [J].
COOPERMAN, M ;
MARTIN, EW ;
KEITH, LM ;
CAREY, LC .
AMERICAN JOURNAL OF SURGERY, 1979, 138 (06) :856-859
[7]  
DYESS DL, 1979, SOUTH MED J, V84, P966
[8]  
HORGAN PG, 1992, SURG CLIN N AM, V72, P143
[9]  
Korenaga D, 1998, HEPATO-GASTROENTEROL, V45, P2179
[10]   PREDICTION OF SMALL BOWEL VIABILITY USING DOPPLER ULTRASOUND - CLINICAL AND EXPERIMENTAL EVALUATION [J].
SHAH, SD ;