Dynamic Navigation for Dental Implant Placement

被引:7
作者
Pinter, Gabor Tamas [1 ]
Decker, Roland [1 ]
Szenasi, Gabor [2 ]
Barabas, Peter [1 ]
Huszar, Tamas [1 ]
机构
[1] Semmelweis Univ, Dept Oro Maxillofacial Surg & Stomatol, Fac Dent, Budapest, Hungary
[2] Semmelweis Univ, Doctoral Sch Theoret & Translat Med, Sch PhD Studies, Budapest, Hungary
来源
JOVE-JOURNAL OF VISUALIZED EXPERIMENTS | 2022年 / 187期
关键词
ACCURACY;
D O I
10.3791/63400
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
In modern implantology, the application of surgical navigation systems is becoming increasingly important. In addition to static surgical navigation methods, a guide-independent dynamic navigation implant placement procedure is becoming more widespread. The procedure is based on computer-guided dental implant placement utilizing optical control. This work aims to demonstrate the technical steps of a new dynamic computer-aided implant surgery (DCAIS) system (design, calibration, surgery) and check the accuracy of the results. Based on cone-beam computed tomography (CBCT) scans, the exact positions of implants are determined with dedicated software. The first step of the operation is the calibration of the navigation system, which can be performed in two ways: 1) based on CBCT images taken with a marker or 2) based on CBCT images without markers. Implants are inserted with the aid of real-time navigation according to the preoperative plans. The accuracy of the interventions can be evaluated based on postoperative CBCT images. The preoperative images containing the planned positions of the implants and postoperative CBCT images were compared based on the angulation (degree), platform, and apical deviation (mm) of the implants. To evaluate the data, we calculated the standard deviation (SD), mean, and standard error of the mean (SEM) of deviations within planned and performed implant positions. Differences between the two calibration methods were compared based on this data. Based on the interventions performed so far, the use of DCAIS allows for high-precision implant placement. A calibration system that does not require labeled CBCT recording allows for surgical intervention with similar accuracy as a system that uses labeling. The accuracy of the intervention can be improved by training.
引用
收藏
页数:14
相关论文
共 50 条
[41]   Comparison of the accuracy of dental implant placement using static and dynamic computer-assisted systems: an in vitro study [J].
Zhou, Miao ;
Zhou, Hui ;
Li, Shu-Yi ;
Zhu, Yi-Bo ;
Geng, Yuan-Ming .
JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2021, 122 (04) :343-348
[42]   Evaluation of the accuracy of dynamic navigation versus robot-assisted dental implant placement in models with one missing tooth or multiple missing teeth with a free-end: an in vitro study [J].
Yang, Wen ;
Weng, Jin-Long ;
Sun, Feng ;
Jiao, Hai ;
Ma, Fei-Fei ;
Wu, Bin-Zhang .
JOURNAL OF DENTISTRY, 2025, 161
[43]   A literature review on prosthetically designed guided implant placement and the factors influencing dental implant success [J].
Nulty, Adam .
BRITISH DENTAL JOURNAL, 2024, 236 (03) :169-180
[44]   Accuracy of different registration areas using active and passive dynamic navigation systems in dental implant surgery: An in vitro study [J].
Wu, Bin-Zhang ;
Ma, Fei-Fei ;
Yan, Xiao-Yan ;
Sun, Feng .
CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (08) :888-897
[45]   Prospective Randomized clinical comparison of 2 dental implant navigation systems [J].
Wittwer, Gert ;
Adeyemo, Wasiu Lanre ;
Schicho, Kurt ;
Birkfellner, Wolfgang ;
Enislidis, Georg .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2007, 22 (05) :785-790
[46]   Computer-Guided Surgery for Dental Implant Placement: A Systematic Review [J].
Araujo-Corchado, Elena ;
Pardal-Pelaez, Beatriz .
PROSTHESIS, 2022, 4 (04) :540-553
[47]   Robot-assisted surgery for dental implant placement: A narrative review [J].
Wang, Miaozhen ;
Liu, Feng ;
Zhao, Xu ;
Wu, Yuwei .
JOURNAL OF DENTISTRY, 2024, 146
[48]   Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla [J].
Shen, Yihan ;
Dai, Qinggang ;
Tao, Baoxin ;
Huang, Wei ;
Wang, Feng ;
Lan, Kengliang ;
Sun, Yuanyuan ;
Ling, Xiaowan ;
Yan, Lijun ;
Wang, Yueping ;
Wu, Yiqun .
JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2021, (176)
[49]   Analysis of the accuracy of a dynamic navigation system when performing dental implant surgery with transcrestal sinus floor elevation: A pilot study [J].
Wu, Bin-Zhang ;
Ma, Fei-Fei ;
Sun, Feng .
JOURNAL OF DENTAL SCIENCES, 2023, 18 (04) :1747-1755
[50]   Dynamic navigation-guided robotic placement of zygomatic implants [J].
Al-Jarsha, Mohammed Y. ;
Diao, Yufeng ;
Zhao, Guodong ;
Imran, Muhammad A. ;
Ayoub, Ashraf F. ;
Robertson, Douglas P. ;
Naudi, Kurt B. .
JOURNAL OF DENTISTRY, 2025, 153