Dynamic Navigation for Dental Implant Placement

被引:5
|
作者
Pinter, Gabor Tamas [1 ]
Decker, Roland [1 ]
Szenasi, Gabor [2 ]
Barabas, Peter [1 ]
Huszar, Tamas [1 ]
机构
[1] Semmelweis Univ, Dept Oro Maxillofacial Surg & Stomatol, Fac Dent, Budapest, Hungary
[2] Semmelweis Univ, Doctoral Sch Theoret & Translat Med, Sch PhD Studies, Budapest, Hungary
来源
JOVE-JOURNAL OF VISUALIZED EXPERIMENTS | 2022年 / 187期
关键词
ACCURACY;
D O I
10.3791/63400
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
In modern implantology, the application of surgical navigation systems is becoming increasingly important. In addition to static surgical navigation methods, a guide-independent dynamic navigation implant placement procedure is becoming more widespread. The procedure is based on computer-guided dental implant placement utilizing optical control. This work aims to demonstrate the technical steps of a new dynamic computer-aided implant surgery (DCAIS) system (design, calibration, surgery) and check the accuracy of the results. Based on cone-beam computed tomography (CBCT) scans, the exact positions of implants are determined with dedicated software. The first step of the operation is the calibration of the navigation system, which can be performed in two ways: 1) based on CBCT images taken with a marker or 2) based on CBCT images without markers. Implants are inserted with the aid of real-time navigation according to the preoperative plans. The accuracy of the interventions can be evaluated based on postoperative CBCT images. The preoperative images containing the planned positions of the implants and postoperative CBCT images were compared based on the angulation (degree), platform, and apical deviation (mm) of the implants. To evaluate the data, we calculated the standard deviation (SD), mean, and standard error of the mean (SEM) of deviations within planned and performed implant positions. Differences between the two calibration methods were compared based on this data. Based on the interventions performed so far, the use of DCAIS allows for high-precision implant placement. A calibration system that does not require labeled CBCT recording allows for surgical intervention with similar accuracy as a system that uses labeling. The accuracy of the intervention can be improved by training.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Evaluation of a dynamic navigation system for training students in dental implant placement
    Zhan, Yalin
    Wang, Miaozhen
    Cheng, Xueyuan
    Li, Yi
    Shi, Xiaorui
    Liu, Feng
    JOURNAL OF DENTAL EDUCATION, 2021, 85 (02) : 120 - 127
  • [2] Accuracy of dynamic navigation compared to static surgical guide for dental implant placement
    Wu, Dong
    Zhou, Lin
    Yang, Jin
    Zhang, Bao
    Lin, Yanjun
    Chen, Jiang
    Huang, Wenxiu
    Chen, Yonghui
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2020, 6 (01)
  • [3] Accuracy of Dynamic Navigation for Dental Implant Placement-Model-Based Evaluation
    Emery, Robert W.
    Merritt, Scott A.
    Lank, Kathryn
    Gibbs, Jason D.
    JOURNAL OF ORAL IMPLANTOLOGY, 2016, 42 (05) : 399 - 405
  • [4] Accuracy of dynamic navigation compared to static surgical guide for dental implant placement
    Dong Wu
    Lin Zhou
    Jin Yang
    Bao Zhang
    Yanjun Lin
    Jiang Chen
    Wenxiu Huang
    Yonghui Chen
    International Journal of Implant Dentistry, 6
  • [5] Dynamic Navigation for Dental Implant Surgery
    Panchal, Neeraj
    Mahmood, Laith
    Retana, Armando
    Emery, Robert, III
    ORAL AND MAXILLOFACIAL SURGERY CLINICS OF NORTH AMERICA, 2019, 31 (04) : 539 - +
  • [6] Implant Placement Accuracy Using Dynamic Navigation
    Block, Michael S.
    Emery, Robert W.
    Lank, Kathryn
    Ryan, James
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (01) : 92 - 99
  • [7] Accuracy of dental implant placement using different dynamic navigation and robotic systems: an in vitro study
    Xu, Zonghe
    Zhou, Lin
    Han, Bin
    Wu, Shuang
    Xiao, Yanjun
    Zhang, Sihui
    Chen, Jiang
    Guo, Jianbin
    Wu, Dong
    NPJ DIGITAL MEDICINE, 2024, 7 (01):
  • [8] Dynamic navigation for dental implant placement in single-tooth gaps: A preclinical pilot investigation
    Bose, Mats Wernfried Heinrich
    Beuer, Florian
    Schwitalla, Andreas
    Bruhnke, Maria
    Herklotz, Insa
    JOURNAL OF DENTISTRY, 2022, 125
  • [9] Reliability and accuracy of dynamic navigation for zygomatic implant placement
    Wu, Yiqun
    Tao, Baoxin
    Lan, Kengliang
    Shen, Yihan
    Huang, Wei
    Wang, Feng
    CLINICAL ORAL IMPLANTS RESEARCH, 2022, 33 (04) : 362 - 376
  • [10] Implant Placement Is More Accurate Using Dynamic Navigation
    Block, Michael S.
    Emery, Robert W.
    Cullum, Daniel R.
    Sheikh, Ali
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2017, 75 (07) : 1377 - 1386