Ultrasound single-phase CBE imaging for monitoring radiofrequency ablation

被引:14
|
作者
Zhang, Lin [1 ]
Li, Qiang [1 ]
Wang, Chiao-Yin [2 ,3 ]
Tsui, Po-Hsiang [3 ,4 ,5 ,6 ]
机构
[1] Tianjin Univ, Sch Microelect, Tianjin, Peoples R China
[2] Chang Gung Univ, Grad Inst Clin Med Sci, Coll Med, Taoyuan, Taiwan
[3] Chang Gung Univ, Coll Med, Dept Med Imaging & Radiol Sci, Taoyuan, Taiwan
[4] Chang Gung Univ, Inst Radiol Res, Med Imaging Res Ctr, Taoyuan, Taiwan
[5] Chang Gung Mem Hosp Linkou, Taoyuan, Taiwan
[6] Chang Gung Mem Hosp Linkou, Dept Med Imaging & Intervent, Taoyuan, Taiwan
基金
中国国家自然科学基金;
关键词
Ultrasound; changes in the backscattered energy; radiofrequency ablation; NONINVASIVE TEMPERATURE ESTIMATION; THERMAL ABLATION; IN-VITRO; POLYNOMIAL-APPROXIMATION; ECHO-SHIFTS; ELASTOGRAPHY; ATTENUATION; DEPENDENCE; TISSUE;
D O I
10.1080/02656736.2018.1512160
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Radiofrequency (RF) ablation (RFA) is the most commonly used minimally invasive procedure for thermal ablation of liver tumors. Ultrasound not only provides real-time feedback of the electrode location for RFA guidance but also enables visualization of the tissue temperature. Changes in backscattered energy (CBE) have been widely applied to ultrasound temperature imaging for assessing thermal ablation. Pilot studies have revealed that significant shadowing features appear in CBE imaging and are caused by the electrode and RFA-induced gas bubbles. To resolve this problem, the current study proposed ultrasound single-phase CBE imaging based on positive CBE values. An in vitro model with tissue samples derived from the porcine tenderloin was used to validate the proposed method. During RFA with various electrode lengths, ultrasound scans of tissue samples were obtained using a clinical ultrasound scanner equipped with a convex array transducer of 3 MHz. Raw image data comprising 256 scan lines of backscattered RF signals were acquired for B-mode, conventional CBE, and single-phase CBE imaging by using the proposed algorithmic scheme. The ablation sizes estimated using CBE imaging and gross examinations were compared to calculate the correlation coefficient. The experimental results indicated that single-phase CBE imaging largely suppressed artificial CBE information in the shadowed region. Moreover, compared with conventional CBE imaging, single-phase CBE imaging provided a more accurate estimation of ablation sizes (the correlation coefficient was higher than 0.8).
引用
收藏
页码:548 / 558
页数:11
相关论文
共 50 条
  • [41] Endoscopic Ultrasound Guided Radiofrequency Ablation in Pancreas
    Seicean, Andrada
    Tefas, Cristian
    Ungureanu, Bogdan
    Saftoiu, Adrian
    HEPATO-GASTROENTEROLOGY, 2014, 61 (134) : 1717 - 1721
  • [42] Ultrasound-guided radiofrequency ablation for papillary thyroid microcarcinoma: a retrospective analysis of 198 patients
    Wu, Rong
    Luo, Yukun
    Tang, Jie
    Yang, Ming
    Li, Jie
    Zhang, Ying
    Zhang, Mingbo
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2020, 37 (01) : 168 - 174
  • [43] Ultrasound-Guided Intratumoral Radiofrequency Ablation Coagulation to Facilitate Meningioma Resection Preliminary Experience
    Yan, Li
    Yang, Junle
    Zhou, Xiaodong
    He, Guangbin
    Zheng, Yu
    Zhu, Yali
    Liu, Weiping
    Luo, Wen
    Qin, Haiying
    Liu, Haijing
    Yi, Xicai
    Zhou, Yin
    JOURNAL OF ULTRASOUND IN MEDICINE, 2018, 37 (03) : 577 - 583
  • [44] Ultrasound Delta CBE Imaging: A New Approach Based on Local Energy Subtraction to Localization of the HIFU Focal Spot Using Changes in Backscattered Energy
    Yang, Kun
    Li, Qiang
    Zhou, Xiaowei
    Wang, Chiao-Yin
    Tsui, Po-Hsiang
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2024, 44 (04) : 618 - 627
  • [45] Effectiveness of impedance monitoring during radiofrequency ablation for predicting popping
    Iida, Hiroya
    Aihara, Tsukasa
    Ikuta, Shinichi
    Yamanaka, Naoki
    WORLD JOURNAL OF GASTROENTEROLOGY, 2012, 18 (41) : 5870 - 5878
  • [46] A Systemic Study on the Performance of Different Quantitative Ultrasound Imaging Techniques for Microwave Ablation Monitoring of Liver
    Yang, Guang
    Zhang, Siyuan
    Li, Xiejing
    Shen, Ting
    Jia, Xin
    Ding, Yunjie
    Zhang, Bo
    Wang, Hua
    Li, Xiaopeng
    Ren, Pengyu
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [47] TOWARDS OPTICAL MONITORING OF RADIOFREQUENCY ABLATION EXTENT FOR ATRIAL FIBRILLATION
    Singh-Moon, Rajinder P.
    Hendon, Christine P.
    2015 IEEE 12TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2015, : 751 - 755
  • [48] IN VIVO THERMAL ABLATION MONITORING USING ULTRASOUND ECHO DECORRELATION IMAGING
    Subramanian, Swetha
    Rudich, Steven M.
    Alqadah, Amel
    Karunakaran, Chandra Priya
    Rao, Marepalli B.
    Mast, T. Douglas
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (01) : 102 - 114
  • [49] Ultrasound Monitoring of In Vitro Radio Frequency Ablation by Echo Decorrelation Imaging
    Mast, T. Douglas
    Pucke, Daniel P.
    Subramanian, Swetha E.
    Bowus, William J.
    Rudich, Steven M.
    Buell, Joseph F.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2008, 27 (12) : 1685 - 1697
  • [50] Comparison of cardiac displacement and strain imaging using ultrasound radiofrequency and envelope signals
    Ma, Chi
    Varghese, Tomy
    ULTRASONICS, 2013, 53 (03) : 782 - 792