Ultrasound single-phase CBE imaging for monitoring radiofrequency ablation

被引:14
|
作者
Zhang, Lin [1 ]
Li, Qiang [1 ]
Wang, Chiao-Yin [2 ,3 ]
Tsui, Po-Hsiang [3 ,4 ,5 ,6 ]
机构
[1] Tianjin Univ, Sch Microelect, Tianjin, Peoples R China
[2] Chang Gung Univ, Grad Inst Clin Med Sci, Coll Med, Taoyuan, Taiwan
[3] Chang Gung Univ, Coll Med, Dept Med Imaging & Radiol Sci, Taoyuan, Taiwan
[4] Chang Gung Univ, Inst Radiol Res, Med Imaging Res Ctr, Taoyuan, Taiwan
[5] Chang Gung Mem Hosp Linkou, Taoyuan, Taiwan
[6] Chang Gung Mem Hosp Linkou, Dept Med Imaging & Intervent, Taoyuan, Taiwan
基金
中国国家自然科学基金;
关键词
Ultrasound; changes in the backscattered energy; radiofrequency ablation; NONINVASIVE TEMPERATURE ESTIMATION; THERMAL ABLATION; IN-VITRO; POLYNOMIAL-APPROXIMATION; ECHO-SHIFTS; ELASTOGRAPHY; ATTENUATION; DEPENDENCE; TISSUE;
D O I
10.1080/02656736.2018.1512160
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Radiofrequency (RF) ablation (RFA) is the most commonly used minimally invasive procedure for thermal ablation of liver tumors. Ultrasound not only provides real-time feedback of the electrode location for RFA guidance but also enables visualization of the tissue temperature. Changes in backscattered energy (CBE) have been widely applied to ultrasound temperature imaging for assessing thermal ablation. Pilot studies have revealed that significant shadowing features appear in CBE imaging and are caused by the electrode and RFA-induced gas bubbles. To resolve this problem, the current study proposed ultrasound single-phase CBE imaging based on positive CBE values. An in vitro model with tissue samples derived from the porcine tenderloin was used to validate the proposed method. During RFA with various electrode lengths, ultrasound scans of tissue samples were obtained using a clinical ultrasound scanner equipped with a convex array transducer of 3 MHz. Raw image data comprising 256 scan lines of backscattered RF signals were acquired for B-mode, conventional CBE, and single-phase CBE imaging by using the proposed algorithmic scheme. The ablation sizes estimated using CBE imaging and gross examinations were compared to calculate the correlation coefficient. The experimental results indicated that single-phase CBE imaging largely suppressed artificial CBE information in the shadowed region. Moreover, compared with conventional CBE imaging, single-phase CBE imaging provided a more accurate estimation of ablation sizes (the correlation coefficient was higher than 0.8).
引用
收藏
页码:548 / 558
页数:11
相关论文
共 50 条
  • [31] Efficiency of contrast enhanced ultrasound for immediate assessment of ablation status after intraoperative radiofrequency ablation of hepatic malignancies
    da Silva, N. Platz Batista
    Beyer, L. P.
    Hottenrott, M. C.
    Hackl, C.
    Schlitt, H. J.
    Stroszczynski, C.
    Wiggermann, P.
    Jung, E. M.
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2017, 66 (04) : 357 - 368
  • [32] Ultrasound-guided ablation of malignant liver tumors: Radiofrequency and microwave ablation
    Kasten P.
    Potthoff A.
    Der Gastroenterologe, 2018, 13 (4): : 284 - 291
  • [33] Frequency-domain CBE imaging for ultrasound localization of the HIFU focal spot: a feasibility study
    Yang, Kun
    Li, Qiang
    Liu, Hao-Li
    Chen, Chin-Kuo
    Huang, Cheng-Wei
    Chen, Jheng-Ru
    Tsai, Yu-Wei
    Zhou, Zhuhuang
    Tsui, Po-Hsiang
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [34] Optical Fiber Ultrasound Probe for Radiofrequency Ablation Temperature Monitoring: In-Vitro Results
    Guo, Xu
    Zhou, Jingcheng
    Du, Cong
    Wang, Xingwei
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2020, 32 (12) : 689 - 692
  • [35] Intracardiac echocardiographic imaging in guiding and monitoring radiofrequency catheter ablation at the tricuspid annulus
    Ren, JF
    Schwartzman, D
    Callas, DJ
    Marchlinski, FE
    Zhang, LP
    Chaudhry, FA
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1998, 15 (07): : 661 - 664
  • [36] Ultrasound monitoring of temperature change during radiofrequency ablation:: Preliminary in-vivo results
    Varghese, T
    Zagzebski, JA
    Chen, Q
    Techavipoo, U
    Frank, G
    Johnson, C
    Wright, A
    Lee, FT
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (03) : 321 - 329
  • [37] In Vivo Thermal Ablation Monitoring by Echo Decorrelation Imaging
    Subramanian, Swetha
    Rudich, Steven M.
    Alqadah, Amel
    Karunakaran, Chandra Priya
    Mast, T. Douglas
    11TH INTERNATIONAL SYMPOSIUM ON THERAPEUTIC ULTRASOUND, 2012, 1481 : 374 - 380
  • [38] Determination of lesion size by ultrasound during radiofrequency catheter ablation
    Awad, S
    Eick, O
    BIOMEDIZINISCHE TECHNIK, 2003, 48 (7-8): : 197 - 201
  • [39] Percutaneous Radiofrequency Ablation of Malignant Liver Tumors with Ultrasound and CT Fusion Imaging Guidance
    Xu, Zuo-Feng
    Xie, Xiao-Yan
    Kuang, Ming
    Liu, Guang-Jian
    Chen, Li-Da
    Zheng, Yan-Ling
    Lu, Ming-De
    JOURNAL OF CLINICAL ULTRASOUND, 2014, 42 (06) : 321 - 330
  • [40] Conformal Radiofrequency Ablation to Validate Ultrasound Thermometry
    Audigier, Chloe
    Kim, Younsu
    Ziegle, Jens
    Friebe, Michael
    Boctor, Emad M.
    MEDICAL IMAGING 2019: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2019, 10951