Ultrasound single-phase CBE imaging for monitoring radiofrequency ablation

被引:14
|
作者
Zhang, Lin [1 ]
Li, Qiang [1 ]
Wang, Chiao-Yin [2 ,3 ]
Tsui, Po-Hsiang [3 ,4 ,5 ,6 ]
机构
[1] Tianjin Univ, Sch Microelect, Tianjin, Peoples R China
[2] Chang Gung Univ, Grad Inst Clin Med Sci, Coll Med, Taoyuan, Taiwan
[3] Chang Gung Univ, Coll Med, Dept Med Imaging & Radiol Sci, Taoyuan, Taiwan
[4] Chang Gung Univ, Inst Radiol Res, Med Imaging Res Ctr, Taoyuan, Taiwan
[5] Chang Gung Mem Hosp Linkou, Taoyuan, Taiwan
[6] Chang Gung Mem Hosp Linkou, Dept Med Imaging & Intervent, Taoyuan, Taiwan
基金
中国国家自然科学基金;
关键词
Ultrasound; changes in the backscattered energy; radiofrequency ablation; NONINVASIVE TEMPERATURE ESTIMATION; THERMAL ABLATION; IN-VITRO; POLYNOMIAL-APPROXIMATION; ECHO-SHIFTS; ELASTOGRAPHY; ATTENUATION; DEPENDENCE; TISSUE;
D O I
10.1080/02656736.2018.1512160
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Radiofrequency (RF) ablation (RFA) is the most commonly used minimally invasive procedure for thermal ablation of liver tumors. Ultrasound not only provides real-time feedback of the electrode location for RFA guidance but also enables visualization of the tissue temperature. Changes in backscattered energy (CBE) have been widely applied to ultrasound temperature imaging for assessing thermal ablation. Pilot studies have revealed that significant shadowing features appear in CBE imaging and are caused by the electrode and RFA-induced gas bubbles. To resolve this problem, the current study proposed ultrasound single-phase CBE imaging based on positive CBE values. An in vitro model with tissue samples derived from the porcine tenderloin was used to validate the proposed method. During RFA with various electrode lengths, ultrasound scans of tissue samples were obtained using a clinical ultrasound scanner equipped with a convex array transducer of 3 MHz. Raw image data comprising 256 scan lines of backscattered RF signals were acquired for B-mode, conventional CBE, and single-phase CBE imaging by using the proposed algorithmic scheme. The ablation sizes estimated using CBE imaging and gross examinations were compared to calculate the correlation coefficient. The experimental results indicated that single-phase CBE imaging largely suppressed artificial CBE information in the shadowed region. Moreover, compared with conventional CBE imaging, single-phase CBE imaging provided a more accurate estimation of ablation sizes (the correlation coefficient was higher than 0.8).
引用
收藏
页码:548 / 558
页数:11
相关论文
共 50 条
  • [1] Ultrasound single-phase CBE imaging for monitoring radiofrequency ablation of the liver tumor: A preliminary clinical validation
    Wang, Chiao-Yin
    Zhou, Zhuhuang
    Chang, Yu-Hsuan
    Ho, Ming-Chih
    Lu, Chiu-Min
    Wu, Chih-Horng
    Tsui, Po-Hsiang
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [2] Monitoring radiofrequency ablation with ultrasound Nakagami imaging
    Wang, Chiao-Yin
    Geng, Xiaonan
    Yeh, Ta-Sen
    Liu, Hao-Li
    Tsui, Po-Hsiang
    MEDICAL PHYSICS, 2013, 40 (07)
  • [3] Adaptive ultrasound temperature imaging for monitoring radiofrequency ablation
    Liu, Yi-Da
    Li, Qiang
    Zhou, Zhuhuang
    Yeah, Yao-Wen
    Chang, Chien-Cheng
    Lee, Chia-Yen
    Tsui, Po-Hsiang
    PLOS ONE, 2017, 12 (08):
  • [4] Phase Contrast Imaging Based Microbubble Monitoring of Radiofrequency Ablation: Anex vivoStudy
    Huang, Wei
    Lu, Jian
    Tang, Rongbiao
    Wu, Zhiyuan
    Wang, Qingbing
    Ding, Xiaoyi
    Wang, Zhongmin
    Chen, Kemin
    FRONTIERS IN ONCOLOGY, 2020, 10
  • [5] Thermoacoustic CBE imaging for monitoring microwave ablation of the liver: A feasibility study
    Feng, Lian
    Song, Ling
    Yang, Zeqi
    Song, Jieni
    Peng, Wanting
    Wu, Zhenru
    Huang, Lin
    Luo, Yan
    APPLIED PHYSICS LETTERS, 2024, 125 (21)
  • [6] Ultrasound-Guided Radiofrequency Ablation of Chemodectomas in Five Dogs
    Gomez Ochoa, Pablo
    Alferez, Maria Dolores
    de Blas, Ignacio
    Fernendes, Telmo
    Sanchez Salguero, Xavier
    Balana, Beatriz
    Melendez Lazo, Antonio
    Barbero Fernandez, Alicia
    Caivano, Domenico
    Corda, Francesca
    Corda, Andrea
    ANIMALS, 2021, 11 (10):
  • [7] Combination of Window-Modulated Ultrasound Nakagami Imaging and Gaussian Approximation for Radiofrequency Ablation Monitoring: An In Vitro Study
    Xin Guan
    Heng Du
    Qiang Li
    Po-Hsiang Tsui
    Journal of Medical and Biological Engineering, 2018, 38 : 173 - 185
  • [8] Combination of Window-Modulated Ultrasound Nakagami Imaging and Gaussian Approximation for Radiofrequency Ablation Monitoring: An In Vitro Study
    Guan, Xin
    Du, Heng
    Li, Qiang
    Tsui, Po-Hsiang
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2018, 38 (02) : 173 - 185
  • [9] Minimally invasive photoacoustic imaging for device guidance and monitoring of radiofrequency ablation
    Joseph, Francis Kalloor
    Kruit, Hindrik
    Rascevska, Elina
    Manohar, Srirang
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2020, 2020, 11240
  • [10] A survey of ultrasound elastography approaches to percutaneous ablation monitoring
    Zhou, Zhuhuang
    Wu, Weiwei
    Wu, Shuicai
    Xia, Jingjing
    Wang, Chiao-Yin
    Yang, Chunlan
    Lin, Chung-Chih
    Tsui, Po-Hsiang
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2014, 228 (10) : 1069 - 1082