Finite element analysis of a bone healing model: 1-year follow-up after internal fixation surgery for femoral fracture

被引:5
作者
Zhou Jiang-jun [1 ]
Zhao Min [1 ]
Yan Ya-bo [2 ]
Lei Wei [2 ]
Lv Ren-fa [1 ]
Zhu Zhi-yu [1 ]
Chen Rong-jian [1 ]
Yu Wei-tao [1 ]
Du Cheng-fei [3 ]
机构
[1] 184th Hosp Chinese PLA, Dept Orthoped, Yingtan 335000, Jiangxi, Peoples R China
[2] Fourth Mil Med Univ, Xijing Hosp, Dept Orthoped, Xian 710032, Shannxi Provinc, Peoples R China
[3] Beihang Univ, Sch Biol Sci & Med Engn, Beijing 100191, Peoples R China
关键词
Biomechanics; Bone healing model; Finite element analysis; Femur fracture; Intramedullary pin; VALIDATION; TISSUE;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Finite element analysis was used to compare preoperative and postoperative stress distribution of a bone healing model of femur fracture, to identify whether broken ends of fractured bone would break or not after fixation dislodgement one year after intramedullary nailing. Methods: Using fast, personalized imaging, bone healing models of femur fracture were constructed based on data from multi-slice spiral computed tomography using Mimics, Geomagic Studio, and Abaqus software packages. The intramedullary pin was removed by Boolean operations before fixation was dislodged. Loads were applied on each model to simulate a person standing on one leg. The von Mises stress distribution, maximum stress, and its location was observed. Results: According to 10 kinds of display groups based on material assignment, the nodes of maximum and minimum von Mises stress were the same before and after dislodgement, and all nodes of maximum von Mises stress were outside the fracture line. The maximum von Mises stress node was situated at the bottom quarter of the femur. The von Mises stress distribution was identical before and after surgery. Conclusion: Fast, personalized model establishment can simulate fixation dislodgement before operation, and personalized finite element analysis was performed to successfully predict whether nail dislodgement would disrupt femur fracture or not.
引用
收藏
页码:343 / 347
页数:5
相关论文
共 21 条
[1]   Image-based musculoskeletal modeling: Applications, advances, and future opportunities [J].
Blemker, Silvia S. ;
Asakawa, Deanna S. ;
Gold, Garry E. ;
Delp, Scott L. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (02) :441-451
[2]   Finite element modeling mesh quality, energy balance and validation methods: A review with recommendations associated with the modeling of bone tissue [J].
Burkhart, Timothy A. ;
Andrews, David M. ;
Dunning, Cynthia E. .
JOURNAL OF BIOMECHANICS, 2013, 46 (09) :1477-1488
[3]   Preoperative planning in pelvic and acetabular surgery: The value of advanced computerised planning modules [J].
Cimerman, Matej ;
Kristan, Anze .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2007, 38 (04) :442-449
[4]  
[杜长岭 du Changling], 2012, [医用生物力学, Journal of Medical Biomechanics], V27, P603
[5]   Finite element simulation of the hip joint during stumbling: a comparison between static and dynamic loading [J].
El'Sheikh, HF ;
MacDonald, BJ ;
Hashmi, MSJ .
JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2003, 143 :249-255
[6]  
[姜海波 JIANG Haibo], 2007, [工程力学, Engineering Mechanics], V24, P156
[7]   Comparison of geometry-based and CT voxel-based finite element modelling and experimental validation [J].
Lengsfeld, M ;
Schmitt, J ;
Alter, P ;
Kaminsky, J ;
Leppek, R .
MEDICAL ENGINEERING & PHYSICS, 1998, 20 (07) :515-522
[8]   Dental implant induced bone remodeling and associated algorithms [J].
Lin, Daniel ;
Li, Qing ;
Li, Wei ;
Swain, Michael .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2009, 2 (05) :410-432
[9]  
Ren ShiHong Ren ShiHong, 2011, Progress in Modern Biomedicine, V11, P1318
[10]  
Shen Hua, 2001, Chinese Journal of Biomedical Engineering, V20, P182