A cobalt(II)-selective PVC membrane based on a Schiff base complex of N,N′-bis(salicylidene)-3,4-diaminotoluene

被引:353
作者
Gupta, VK [1 ]
Singh, AK [1 ]
Mehtab, S [1 ]
Gupta, B [1 ]
机构
[1] Indian Inst Technol, Dept Chem, Roorkee 247667, Uttar Pradesh, India
关键词
cobalt-selective electrode; PVC membrane electrodes; Schiff base and potentiometric sensors;
D O I
10.1016/j.aca.2006.02.038
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new PVC membrane electrode for Co2+ based on N,N'-bis(salicylidene)-3,4-diaminotoluene, an excellent neutral carrier, has been fabricated using sodium tetraphenylborate (NaTPB) as an anionic excluder and dioctylphthalte (DOP) as a solvent mediator. The electrode exhibits a linear potential response in the concentration range of 7.9 x 10(-8) to 1.0 x 10(-1) M with a slope of 30 +/- 0.2 mV per decade. The detection limit of the proposed sensor is 5.0 x 10(-8) M and it can be used over a period of 5 months. The proposed sensor revealed good selectivity over a wide variety of other cations including alkali, alkaline earth, heavy and transition metals and could be used in the pH range of 2.0-9.0. This electrode was successfully applied for the determination of Co2+ in real samples and as an indicator electrode in potentiometric titration of cobalt ions. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:5 / 10
页数:6
相关论文
共 54 条
[21]   A zinc-selective electrode based on N,N′-bis(acetylacetone)ethylenediimine [J].
Gupta, VK ;
Agarwal, S ;
Jakob, A ;
Lang, H .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 114 (02) :812-818
[22]   A copper-selective electrode based on bis(acetylacetone)propylenediimine [J].
Gupta, VK ;
Goyal, RN ;
Bachheti, N ;
Singh, LP ;
Agarwal, S .
TALANTA, 2005, 68 (02) :193-197
[23]   PVC MATRIX MEMBRANE ELECTRODES BASED ON COBALT AND NICKEL PHENANTHROLINE COMPLEXES FOR SELECTIVE DETERMINATION OF COBALT(II) AND NICKEL(II) IONS [J].
HASSAN, SSM ;
MAHMOUD, WH .
MIKROCHIMICA ACTA, 1995, 117 (3-4) :121-128
[24]   NITRATE-SELECTIVE ELECTRODE DEVELOPED BY ELECTROCHEMICALLY MEDIATED IMPRINTING DOPING OF POLYPYRROLE [J].
HUTCHINS, RS ;
BACHAS, LG .
ANALYTICAL CHEMISTRY, 1995, 67 (10) :1654-1660
[25]   Macrocycle based membrane sensors for the determination of cobalt(II) ions [J].
Jain, AK ;
Gupta, VK ;
Singh, LP ;
Khurana, U .
ANALYST, 1997, 122 (06) :583-586
[26]   Ni(II)-selective ion sensors of salen type Schiff base chelates [J].
Jain, AK ;
Gupta, VK ;
Ganeshpure, PA ;
Raisoni, JR .
ANALYTICA CHIMICA ACTA, 2005, 553 (1-2) :177-184
[27]   Rubeanic acid as novel carrier in construction of selective membrane sensor for La(III) [J].
Jain, AK ;
Singh, AK ;
Mehtab, S ;
Saxena, P .
ANALYTICA CHIMICA ACTA, 2005, 551 (1-2) :45-50
[28]   A lead (II)-selective PVC membrane based on a Schiff base complex of N,N'-bis(salicylidene)-2,6-pyridinediamine [J].
Jeong, T ;
Lee, HK ;
Jeong, DC ;
Jeon, S .
TALANTA, 2005, 65 (02) :543-548
[29]   Thallium(I)-selective membrane electrodes based on calix[6]arene or calix[5]arene derivatives [J].
Katsu, T ;
Ido, K ;
Takaishi, K ;
Yokosu, H .
SENSORS AND ACTUATORS B-CHEMICAL, 2002, 87 (02) :331-335
[30]  
Khayatian G, 2003, B KOR CHEM SOC, V24, P421