Mean amplitude of intraocular pressure excursions: a new assessment parameter for 24-h pressure fluctuations in glaucoma patients

被引:6
|
作者
Zhai, Ruyi [1 ,2 ,3 ,4 ]
Cheng, Jingyi [1 ,2 ,3 ,4 ]
Xu, Huan [1 ,2 ,3 ,4 ]
Fang, Zhaobin [5 ]
Chen, Xu [5 ]
Qiu, Siyu [5 ]
Sun, Xinghuai [1 ,2 ,3 ,4 ,6 ,7 ]
Lee, Richard K. [8 ]
Xiao, Ming [5 ]
Kong, Xiangmei [1 ,2 ,3 ,4 ]
机构
[1] Fudan Univ, Dept Ophthalmol & Visual Sci, Eye Ear Nose & Throat Hosp, Shanghai Med Coll, Shanghai, Peoples R China
[2] Fudan Univ, Shanghai Key Lab Visual Impairment & Restorat, Shanghai, Peoples R China
[3] Fudan Univ, NHC Key Lab Myopia, Shanghai, Peoples R China
[4] Chinese Acad Med Sci, Lab Myopia, Shanghai, Peoples R China
[5] Shanghai Jingan Dist Beizhan Hosp, Dept Ophthalmol, Shanghai, Peoples R China
[6] Fudan Univ, State Key Lab Med Neurobiol, Inst Brain Sci, Shanghai, Peoples R China
[7] Fudan Univ, Collaborat Innovat Ctr Brain Sci, Shanghai, Peoples R China
[8] Univ Miami, Miller Sch Med, Bascom Palmer Eye Inst, Miami, FL 33136 USA
基金
中国国家自然科学基金;
关键词
VISUAL-FIELD PROGRESSION; NORMAL-TENSION GLAUCOMA; CONTACT-LENS SENSOR; OPEN-ANGLE GLAUCOMA; RISK-FACTOR; MYOPIA; MANAGEMENT;
D O I
10.1038/s41433-020-0845-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background Intraocular pressure (IOP) is important in the pathogenesis of glaucoma and its circadian fluctuations are important in the disease management; however, there are no adequate parameters to describe the fluctuations. This study investigates a new parameter, mean amplitude of intraocular pressure excursion (MAPE), and compares its ability in assessing 24-h IOP fluctuations with other ocular parameters. Methods Only the right eye was evaluated in each of the 79 healthy people and 164 untreated patients with primary open angle glaucoma (POAG). Each participant underwent 24-h IOP monitoring by measuring IOP every 2 h. IOP fluctuations were expressed as MAPE calculations and currently used parameters included mean IOP, standard deviation of IOP, max difference and area under the circadian IOP curve. Comprehensive ophthalmologic examinations were also performed. Associations between visual field deficits and IOP fluctuation parameters were investigated via partial least squares (PLS) regression. Diagnostic performance was evaluated with area under the receiver operating characteristic curves (ROC). Results Compared with healthy volunteers, the MAPE values in POAG patients were higher (4.16 +/- 1.90 versus 2.45 +/- 0.89,p < 0.01). In PLS regressions where visual field deficits were as dependent variable, MAPE had the highest score regarding variable importance in projection, and its standard regression coefficient was larger than other parameters. Diagnostic performance analysis showed the area under ROC of MAPE for glaucoma detection was 0.822 (0.768-0.868,p < 0.001). Conclusions MAPE might be an effective parameter in clinic to characterise IOP circadian fluctuations.
引用
收藏
页码:326 / 333
页数:8
相关论文
共 50 条
  • [41] 24-h ambulatory blood pressure variability and hypertensive nephropathy in Han Chinese hypertensive patients
    Hung, Ming-Hui
    Huang, Chin-Chou
    Chung, Chia-Min
    Chen, Jaw-Wen
    JOURNAL OF CLINICAL HYPERTENSION, 2021, 23 (02) : 281 - 288
  • [42] Long-term blood pressure monitoring by office and 24-h ambulatory blood pressure in renal transplant patients: a longitudinal study
    Mallamaci, Francesca
    Tripepi, Rocco
    D'Arrigo, Graziella
    Porto, Gaetana
    Versace, Maria Carmela
    Marino, Carmela
    Sanguedolce, Maria Cristina
    Testa, Alessandra
    Tripepi, Giovanni
    Zoccali, Carmine
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2019, 34 (09) : 1558 - 1564
  • [43] Comparison of Two Tonometers in the Evaluation of 24-Hour Intraocular Pressure and Mean Ocular Perfusion Pressure in Patients with Thyroid-Associated Ophthalmopathy
    Liu, Weijie
    Zhou, Yao
    Hu, Xiaozhou
    Jin, Haochen
    Ye, Jie
    Xu, Mingna
    Liu, Zihui
    Wu, Wencan
    Tu, Yunhai
    JOURNAL OF OPHTHALMOLOGY, 2022, 2022
  • [44] Transient changes in refractive error and corneal tomography after 24-h continuous monitoring of intraocular pressure patterns with a contact lens sensor
    Atsuya Miki
    Miho Kumoi
    Naoyuki Maeda
    Shizuka Koh
    Kenji Matsushita
    Kohji Nishida
    Japanese Journal of Ophthalmology, 2020, 64 : 127 - 133
  • [45] Transient changes in refractive error and corneal tomography after 24-h continuous monitoring of intraocular pressure patterns with a contact lens sensor
    Miki, Atsuya
    Kumoi, Miho
    Maeda, Naoyuki
    Koh, Shizuka
    Matsushita, Kenji
    Nishida, Kohji
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2020, 64 (02) : 127 - 133
  • [46] Interventions aimed to increase average 24-h systolic blood pressure reduce blood pressure drops in patients with reflex syncope and orthostatic intolerance
    Groppelli, Antonella
    Rivasi, Giulia
    Fedorowski, Artur
    de Lange, Frederik J.
    Russo, Vincenzo
    Maggi, Roberto
    Capacci, Marco
    Nawaz, Sara
    Comune, Angelo
    Bianchi, Lorenzo
    Zambon, Antonella
    Soranna, Davide
    Ungar, Andrea
    Parati, Gianfranco
    Brignole, Michele
    EUROPACE, 2024, 26 (02):
  • [47] Predicting prognosis in patients with stroke treated with intravenous alteplase through the 24-h trajectory of blood pressure changes
    Fan, Kaiting
    Zhao, Jie
    Chang, Hong
    Wang, Xiaojuan
    Yao, Hui
    Yao, Xiaoxia
    Yang, Xin
    JOURNAL OF CLINICAL HYPERTENSION, 2021, 23 (09) : 1718 - 1730
  • [48] 24-Hour Intraocular Pressure Rhythm in Patients With Untreated Primary Open Angle Glaucoma and Effects of Selective Laser Trabeculoplasty
    Aptel, Florent
    Musson, Cecile
    Zhou, Thierry
    Lesoin, Antoine
    Chiquet, Christophe
    JOURNAL OF GLAUCOMA, 2017, 26 (03) : 272 - 277
  • [49] Assessment of short-term intraocular pressure parameters in phakic and pseudophakic patients with primary open-angle glaucoma
    Lourenco, Adriana Sobral
    Quirino de Araujo, Candice Cristina
    dos Santos, Procopio Miguel
    Prata, Tiago S.
    Lopes, Nara Lidia Vieira
    Ribeiro dos Santos, Regina Candido
    Gracitelli, Carolina P. B.
    Lima de Faria, Nubia Vanessa
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2021, 84 (05) : 425 - 429
  • [50] Individualized Significance of 24-Hour Intraocular Pressure Curves for Therapeutic Decisions in Primary Chronic Open-Angle Glaucoma Patients
    Lever, Mael
    Unterlauft, Jan Darius
    Halfwassen, Christian
    Bechrakis, Nikolaos E.
    Manthey, Anke
    Boehm, Michael R. R.
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 1483 - 1494