CFD simulation of flow in a long street canyon under a perpendicular wind direction: Evaluation of three computational settings

被引:84
作者
Ai, Z. T. [1 ]
Mak, C. M. [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Hong Kong, Hong Kong, Peoples R China
关键词
Street canyon; Flow; CFD; Computational domain; Boundary conditions; LARGE-EDDY SIMULATION; POLLUTANT DISPERSION; AIR-FLOW; TEMPERATURE DISTRIBUTION; NUMERICAL-SIMULATION; PARTICLE DISPERSION; TUNNEL MEASUREMENTS; BUOYANT FLOWS; TURBULENCE; TRANSPORT;
D O I
10.1016/j.buildenv.2016.12.032
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A street canyon is an important platform for the understanding of local atmospheric flow and other related processes in the built environment. Many previous studies focused on long street canyons under a perpendicular wind direction, as they represent the worst street canyon microclimate, such as stagnation of wind and accumulation of pollutants. While CFD simulations were widely applied to investigate atmospheric processes in street canyons, appropriate computational settings are important factors influencing the predictive reliability. A non-exhaustive literature review of CFD studies on atmospheric processes in long street canyons indicates an arbitrary selection of three important computational settings, namely computational domain configuration, domain dimensions and inflow boundary conditions. Based on previous water tunnel experimental data for street canyons with aspect ratio equal to 0.5, 1.0 and 2.0, this study evaluates the influence of the three computational settings on CFD prediction of isothermal flow field inside the street canyons. Flow field inside an urban street canyon cannot be reasonably predicted using an isolated street canyon included in a conventional computational domain, which, however, can be well predicted using a T-shape computational domain where a street canyon is connected to a free flow layer above the canyon. A T-shape domain with the upstream length, downstream length and height above a street canyon all equal to the height of the street canyon is appropriate when considering both computational cost and predictive accuracy. It is reasonable to use uniform inflow boundary conditions to represent the free layer above street canyons. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:293 / 306
页数:14
相关论文
共 74 条
[1]   From street canyon microclimate to indoor environmental quality in naturally ventilated urban buildings: Issues and possibilities for improvement [J].
Ai, Z. T. ;
Mak, C. M. .
BUILDING AND ENVIRONMENT, 2015, 94 :489-503
[2]   Modeling of coupled urban wind flow and indoor air flow on a high-density near-wall mesh: Sensitivity analyses and case study for single-sided ventilation [J].
Ai, Z. T. ;
Mak, C. M. .
ENVIRONMENTAL MODELLING & SOFTWARE, 2014, 60 :57-68
[3]   A study of interunit dispersion around multistory buildings with single-sided ventilation under different wind directions [J].
Ai, Z. T. ;
Mak, C. M. .
ATMOSPHERIC ENVIRONMENT, 2014, 88 :1-13
[4]   CFD simulation of flow and dispersion around an isolated building: Effect of inhomogeneous ABL and near-wall treatment [J].
Ai, Z. T. ;
Mak, C. M. .
ATMOSPHERIC ENVIRONMENT, 2013, 77 :568-578
[5]   Numerical investigation of wind-induced airflow and interunit dispersion characteristics in multistory residential buildings [J].
Ai, Z. T. ;
Mak, C. M. ;
Niu, J. L. .
INDOOR AIR, 2013, 23 (05) :417-429
[6]   Buoyant flows in street canyons: Validation of CFD simulations with wind tunnel measurements [J].
Allegrini, Jonas ;
Dorer, Viktor ;
Carmeliet, Jan .
BUILDING AND ENVIRONMENT, 2014, 72 :63-74
[7]   Wind tunnel measurements of buoyant flows in street canyons [J].
Allegrini, Jonas ;
Dorer, Viktor ;
Carmeliet, Jan .
BUILDING AND ENVIRONMENT, 2013, 59 :315-326
[8]   Investigation of urban canyon microclimate in traditional and contemporary environment. Experimental investigation and parametric analysis [J].
Andreou, E. ;
Axarli, K. .
RENEWABLE ENERGY, 2012, 43 :354-363
[9]  
[Anonymous], 1987, BOUNDARY LAYER CLIMA
[10]  
[Anonymous], 2010, ANSYS FLUENT 13 0 TH