Combination of extraction induced by microemulsion-breaking and pre-concentration using magnetic nanoparticles for multi-element determination of Cd, Cr, Cu and Pb in gasoline samples using energy dispersive X-ray fluorescence spectrometry

被引:25
作者
Meira, Lucilia A. [1 ]
Almeida, Jorge S. [1 ,2 ]
Dias, Fabio de S. [3 ]
Teixeira, Leonardo S. G. [1 ,2 ]
机构
[1] Univ Fed Bahia, Inst Quim, Dept Quim Analit, Campus Univ Ondina, BR-40170115 Salvador, BA, Brazil
[2] Univ Fed Bahia, INCT Energia & Ambiente, Inst Quim, Campus Univ Ondina, BR-40170115 Salvador, BA, Brazil
[3] Univ Fed Reconcavo Bahia, Ctr Ciencias Exatas & Tecnol, Campus Univ Cruz das Almas, BR-44380000 Cruz Das Almas, BA, Brazil
关键词
Gasoline; Multi-element determination; Energy dispersive X-ray fluorescence spectrometry; Magnetic nanoparticles; Extraction induced by microemulsion-breaking; SOLID-PHASE EXTRACTION; ATOMIC-ABSORPTION-SPECTROMETRY; ETHANOL FUEL SAMPLES; AUTOMOTIVE GASOLINE; IRON; COPPER; FE; EMULSIONS; CHROMIUM; REMOVAL;
D O I
10.1016/j.microc.2019.03.068
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The combination of the extraction induced by microemulsion-breaking (EIMB) and preconcentration using the solid-phase extraction (SPE) using magnetic nanoparticles (MNP) for determination of Cd, Cr, Cu and Pb in gasoline samples by energy dispersive X-ray fluorescence spectrometry (EDXRF) is proposed. The procedure was based in the formation of a three components microemulsion: gasoline as organic phase, n-propyl alcohol as an emulsifier and 0.01 mol L-1 HNO3 as aqueous phase. After formation of the microemulsion, Iris/nitric acid buffer (0.1 mol L-1, pH 8.5) was used for the microemulsion breaking and adjust the pH simultaneously. Subsequently, an amount of CoFe2O4 nanoferrite was added to the medium for the retention and preconcentration of the species of interest present in the aqueous phase of the broken emulsion. After a contact time between the nanoparticle and the mixture, the solid phase was separated from the supernatant with the aid of a magnet and, after drying, the determination of the analytes was performed directly on the solid support (nanoferrite) by EDXRF. To guarantee the better extraction conditions, some experimental variables were investigated. The recommended proportion for the microemulsion formation was 65% (v v(-1)) n-propyl alcohol, 20% (v v(-1)) gasoline, and 15% (v v(-1)) nitric acid solution. For the solid phase extraction, 100 mg of nanoferrite and a contact time of 10 min were recommended. Enrichment factors between 10 and 470 times were found for the analytes. The limits of detection obtained by the proposed method were 24, 2.8, 16 and 9.7 mu g L-1 for Cd, Cr, Cu and Pb, respectively. The precisions for determination of each element were expressed as relative standard deviations (RSD) using standard solutions containing 0.2 and 0.4 mg L-1 of each analyte and were between 2.0 and 8.1%. The developed method was applied in the determination of Cd, Cr, Cu and Pb in gasoline samples.
引用
收藏
页码:660 / 665
页数:6
相关论文
共 27 条
[1]   CoFe2O4 nano-particles functionalized with 8-hydroxyquinoline for dispersive solid-phase micro-extraction and direct fluorometric monitoring of aluminum in human serum and water samples [J].
Abdolmohammad-Zadeh, Hossein ;
Rahimpour, Elaheh .
ANALYTICA CHIMICA ACTA, 2015, 881 :54-64
[2]   Phosphate removal from aqueous solution using iron oxides: Adsorption, desorption and regeneration characteristics [J].
Ajmal, Zeeshan ;
Muhmood, Atif ;
Usman, Muhammad ;
Kizito, Simon ;
Lu, Jiaxin ;
Dong, Renjie ;
Wu, Shubiao .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2018, 528 :145-155
[3]   Determination of Pb, Cu and Fe in ethanol fuel samples by high-resolution continuum source electrothermal atomic absorption spectrometry by exploring a combination of sequential and simultaneous strategies [J].
Almeida, Jorge S. ;
Souza, Odara C. C. O. ;
Teixeira, Leonardo S. G. .
MICROCHEMICAL JOURNAL, 2018, 137 :22-26
[4]   Aggregation and disaggregation of iron oxide nanoparticles: Influence of particle concentration, pH and natural organic matter [J].
Baalousha, Mohammed .
SCIENCE OF THE TOTAL ENVIRONMENT, 2009, 407 (06) :2093-2101
[5]   IONIC FERROFLUIDS - A CROSSING OF CHEMISTRY AND PHYSICS [J].
BACRI, JC ;
PERZYNSKI, R ;
SALIN, D ;
CABUIL, V ;
MASSART, R .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 1990, 85 (1-3) :27-32
[6]   Application of pyridylazo and thiazolylazo reagents in flow injection preconcentration systems for determination of metals [J].
Baliza, Patricia Xavier ;
Costa Ferreira, Sergio Luis ;
Gomes Teixeira, Leonardo Sena .
TALANTA, 2009, 79 (01) :2-9
[7]  
BLESA MA, COORD CHEM REV, V196, P31
[8]   Macroemulsion-based dispersive magnetic solid phase extraction for preconcentration and determination of copper(II) in gasoline [J].
Cunha, Francisco Antonio S. ;
Ferreira, Danilo Tadeu S. ;
Andrade, Willy C. R. ;
Fernandes, Julys Pablo A. ;
Lyra, Wellington S. ;
Pessoa, Amalia G. G. ;
Ugulino de Araujo, Mario Cesar .
MICROCHIMICA ACTA, 2018, 185 (02)
[9]  
de Campos RC, 2002, SPECTROCHIM ACTA B, V57, P15
[10]   Use of cetyltrimethylammonium bromide as surfactant for the determination of copper and chromium in gasoline emulsions by electrothermal atomic absorption spectrometry [J].
dos Santos, Denilson S. S. ;
Teixeira, Alete P. ;
Barbosa, Jose T. P. ;
Ferreira, Sergio L. C. ;
Korn, Maria das Gracas A. ;
Teixeira, Leonardo S. G. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (09) :1072-1077