Implementation of a dynamic voltage restorer system based on discrete wavelet transforms

被引:34
作者
Saleh, S. A. [1 ]
Moloney, C. R. [1 ]
Rahman, M. Azizur [1 ]
机构
[1] Mem Univ Newfoundland, St John, NF A1B 3X5, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Butterworth passive LC filters; discrete wavelet transform (DWT); dynamic voltage restorer (DVR) systems and Fourier analysis; DWT-associated finite-impulse response (FIR) filters; power systems transients;
D O I
10.1109/TPWRD.2008.2002868
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents an implementation of the discrete wavelet transform (DWT) using passive LC filters for operating a dynamic voltage restorer (DVR) system. The proposed implementation is based on designing Butterworth passive LC filters with cutoff frequencies that are identical to cutoff frequencies of DWT associated digital filters. These passive LC filters can detect abnormal conditions that may disrupt the quality of the power supplied to sensitive loads in a power system. Detecting any abnormal condition is realized through extracting high- and low-frequency components present in system voltages using high-pass and low-pass filters, respectively. The designed Butterworth passive L passive filters are third-order systems to simplify their practical implementation as well as their integration with the test power system and the DVR. Simulation and experimental test results for transient voltage dip and steady-state harmonic distortion cases show significant performance improvement of the DVR system operated by the designed Butterworth passive LC filters. The proposed DWT-operated DVR system using Butterworth passive LC filters is implemented and tested for improving the power quality under different abnormal conditions.
引用
收藏
页码:2366 / 2375
页数:10
相关论文
共 19 条
[1]   TRENDS IN ACTIVE POWER-LINE CONDITIONERS [J].
AKAGI, H .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1994, 9 (03) :263-268
[2]  
Chui C. K., 1997, WAVELETS MATH TOOL S
[3]   Frequency estimation of distorted power system signals using extended complex Kalman filters [J].
Dash, PK ;
Pradhan, AK ;
Panda, G .
IEEE TRANSACTIONS ON POWER DELIVERY, 1999, 14 (03) :761-766
[4]   Factoring wavelet transforms into lifting steps [J].
Daubechies, I ;
Sweldens, W .
JOURNAL OF FOURIER ANALYSIS AND APPLICATIONS, 1998, 4 (03) :247-269
[5]   A SURVEY OF DISTRIBUTION-SYSTEM POWER QUALITY - PRELIMINARY-RESULTS [J].
GUNTHER, EW ;
MEHTA, H ;
SAVAGE, N .
IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (01) :322-329
[6]   PSCAD/EMTDC simulation of unified series-shunt compensator for power quality improvement [J].
Hannan, AA ;
Mohamed, A .
IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (02) :1650-1656
[7]   A neural-fuzzy classifier for recognition of power quality disturbances [J].
Huang, JS ;
Negnevitsky, M ;
Nguyen, DT .
IEEE TRANSACTIONS ON POWER DELIVERY, 2002, 17 (02) :609-616
[8]   A dulal-functional medium voltage level DVR to limit downstream fault currents [J].
Li, Yuri Wei ;
Vilathgamuwa, D. Mahinda ;
Loh, Poh Chiang ;
Blaabjerg, Frede .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2007, 22 (04) :1330-1340
[9]  
MALLAT S, 1989, IEEE T PATTERN ANAL, V11, P7
[10]   Detection and measurement of power quality disturbances using wavelet transform [J].
Poisson, O ;
Rioual, P ;
Meunier, M .
IEEE TRANSACTIONS ON POWER DELIVERY, 2000, 15 (03) :1039-1044