Ion-exchange chromatography followed by ESI-MS for quantitative analysis of sugar monophosphates from glucose catabolism

被引:10
作者
Walters, JJ
Grayson, MA
Gross, ML
Hughes, M
Shearer, G
Kohl, DH
Bashkin, J
机构
[1] Washington Univ, Dept Chem, St Louis, MO 63130 USA
[2] Washington Univ, Dept Biol, St Louis, MO 63130 USA
[3] Univ Missouri, Dept Chem & Biochem, St Louis, MO 63121 USA
关键词
D O I
10.1016/j.jasms.2005.10.004
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The aim of this work is to establish a quantitative method to determine the ratio of [U-C-13] labeled to unlabeled hexose monophosphates isolated from yeast extracts. This is accomplished by anion exchange chromatography and mobile phase desalting followed by electrospray (ESI) mass spectrometry. We test the method with the analysis of a sample of biological origin. Previously developed analytical techniques are not adequate to accomplish mass spectrometric analysis of these and other small monosaccharide systems because of interference from salt clusters. By lowering the ionic strength of the mobile phase and using a simplified injection system to the mass spectrometer, we were able to obtain data on the relative abundance of the hexose monophosphates.
引用
收藏
页码:104 / 107
页数:4
相关论文
共 8 条
[1]   Evidence for channeling of intermediates in the oxidative pentose phosphate pathway by soybean and pea nodule extracts, yeast extracts, and purified yeast enzymes [J].
Debnam, PM ;
Shearer, G ;
Blackwood, L ;
Kohl, DH .
EUROPEAN JOURNAL OF BIOCHEMISTRY, 1997, 246 (02) :283-290
[2]   Investigation of ion/molecule reactions as a quantification method for phosphorylated positional isomers: An FT-ICR approach [J].
Gao, H ;
Petzold, CJ ;
Leavell, MD ;
Leary, JA .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2003, 14 (08) :916-924
[3]  
Gonzalez B, 1997, YEAST, V13, P1347, DOI 10.1002/(SICI)1097-0061(199711)13:14<1347::AID-YEA176>3.0.CO
[4]  
2-O
[5]   Improved protocols for quantitative determination of metabolites from biological samples using high performance ionic-exchange chromatography with conductimetric and pulsed amperometric detection [J].
Groussac, E ;
Ortiz, M ;
François, J .
ENZYME AND MICROBIAL TECHNOLOGY, 2000, 26 (9-10) :715-723
[6]   Profiling of pentose phosphate pathway intermediates in blood spots by tandem mass spectrometry: Application to transaldolase deficiency [J].
Huck, JHJ ;
Struys, EA ;
Verhoeven, NM ;
Jakobs, C ;
Van der Knaap, MS .
CLINICAL CHEMISTRY, 2003, 49 (08) :1375-1380
[7]   Stable-isotope dilution analysis of galactose metabolites in human erythrocytes [J].
Schadewaldt, P ;
Kamalanathan, L ;
Hammen, HW ;
Wendel, U .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (24) :2833-2838
[8]   Improvements to in-line desalting of oligosaccharides separated by high-pH anion exchange chromatography with pulsed amperometric detection [J].
Thayer, JR ;
Rohrer, JS ;
Avdalovic, N ;
Gearing, RP .
ANALYTICAL BIOCHEMISTRY, 1998, 256 (02) :207-216