Biofouling-resistance expanded poly(tetrafluoroethylene) membrane with a hydrogel-like layer of surface-immobilized poly(ethylene glycol) methacrylate for human plasma protein repulsions

被引:58
作者
Chang, Yung [1 ]
Cheng, Ting-Yun
Shih, Yu-Ju
Lee, Kueir-Rarn
Lai, Juin-Yih
机构
[1] Chung Yuan Christian Univ, R&D Ctr Membrane Technol, Tao Yuan 320, Taiwan
[2] Chung Yuan Christian Univ, Dept Chem Engn, Tao Yuan 320, Taiwan
关键词
poly(tetrafluoroethylene); poly(ethylene glycol) methacrylate; surface-activated plasma treatment; graft copolymerization; plasma proteins; biofouling-resistance; blood compatibility;
D O I
10.1016/j.memsci.2008.06.023
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
in general, it is a challenge to control the highly polar material grafting from the chemically inert Teflon-based membrane surface. This work describes the surface modification and characterization of expanded poly(tetrafluoroethylene) (ePTFE) membranes grafted with poly(ethylene glycol) methacrylate (PEGMA) macromonomer via surface-activated plasma treatment and thermally induced graft copolymerization. The chemical composition and microstructure of the surface-modified ePTFE membranes were characterized by Fourier transform infrared spectroscopy (FT-IR), contact angle, and bio-atomic force microscopy (bio-AFM) measurements. Biofouling property of the modified membranes was evaluated by the measurements of the plasma protein (gamma-globulin, fibrinogen, or albumin) adsorption determined using an enzyme-linked immunosorbent assay (ELISA). In general, the hydrophilicity of the surface of ePTFE membranes increases with increasing the grafting degree of the copolymerized PEGMA. The highly hydrated PEGMA chain on the resulting ePTFE membranes was found to form a surface hydrogel-like layer with regulated coverage in aqueous state, which can be controlled by the content of PEGMA macromonomer in the reaction solution. The relative protein adsorption was effectively reduced with increasing capacity of the hydration for the PEGMA chain grafted on the ePTFE membrane surface. From both results of protein adsorption and platelet adhesion test in vitro, it is concluded that the PEGMA-grafted hydrophilic ePTFE membranes could provide good biofouling resistance to substantially reduce plasma protein and blood platelet fouling on the membrane surface in human body temperature. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:77 / 84
页数:8
相关论文
共 25 条
[1]   Polymer brushes that resist adsorption of model proteins: Design parameters [J].
Halperin, A .
LANGMUIR, 1999, 15 (07) :2525-2533
[2]   Factors that determine the protein resistance of oligoether self-assembled monolayers - Internal hydrophilicity, terminal hydrophilicity, and lateral packing density [J].
Herrwerth, S ;
Eck, W ;
Reinhardt, S ;
Grunze, M .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2003, 125 (31) :9359-9366
[3]   Serum protein adsorption and platelet adhesion on pluronic™-adsorbed polysulfone membranes [J].
Higuchi, A ;
Sugiyama, K ;
Yoon, BO ;
Sakurai, M ;
Hara, M ;
Sumita, M ;
Sugawara, S ;
Shirai, T .
BIOMATERIALS, 2003, 24 (19) :3235-3245
[4]   Surface modification and functionalization of polytetrafluoroethylene films [J].
Kang, ET ;
Tan, KL ;
Kato, K ;
Uyama, Y ;
Ikada, Y .
MACROMOLECULES, 1996, 29 (21) :6872-6879
[5]  
Kang ET, 2000, ADV MATER, V12, P1481, DOI 10.1002/1521-4095(200010)12:20<1481::AID-ADMA1481>3.0.CO
[6]  
2-Z
[7]   Poly(L-lysine)-g-poly(ethylene glycol) layers on metal oxide surfaces:: Attachment mechanism and effects of polymer architecture on resistance to protein adsorption [J].
Kenausis, GL ;
Vörös, J ;
Elbert, DL ;
Huang, NP ;
Hofer, R ;
Ruiz-Taylor, L ;
Textor, M ;
Hubbell, JA ;
Spencer, ND .
JOURNAL OF PHYSICAL CHEMISTRY B, 2000, 104 (14) :3298-3309
[8]  
Lappan U, 1999, J APPL POLYM SCI, V74, P1571, DOI 10.1002/(SICI)1097-4628(19991107)74:6<1571::AID-APP32>3.3.CO
[9]  
2-O
[10]   Surface modification of poly(tetrafluoroethylene) by plasma pretreatment and adsorption of polyelectrolytes [J].
Lappan, U ;
Buchhammer, HM ;
Lunkwitz, K .
POLYMER, 1999, 40 (14) :4087-4091