A novel transient rotor current control scheme of a doubly-fed induction generator equipped with superconducting magnetic energy storage for voltage and frequency support

被引:2
作者
Shen Yang-Wu [1 ]
Ke De-Ping [1 ]
Sun Yuan-Zhang [1 ]
Kirschen, Daniel [2 ]
Wang Yi-Shen [2 ]
Hu Yuan-Chao [1 ]
机构
[1] Wuhan Univ, Sch Elect Engn, Wuhan 430072, Peoples R China
[2] Univ Washington, Dept Elect Engn, Seattle, WA 98195 USA
基金
中国国家自然科学基金;
关键词
doubly-fed induction generator; transient rotor current control; superconducting magnetic energy storage; voltage support; RIDE-THROUGH STRATEGY; DFIG WIND TURBINES;
D O I
10.1088/1674-1056/24/7/070201
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
A novel transient rotor current control scheme is proposed in this paper for a doubly-fed induction generator (DFIG) equipped with a superconducting magnetic energy storage (SMES) device to enhance its transient voltage and frequency support capacity during grid faults. The SMES connected to the DC-link capacitor of the DFIG is controlled to regulate the transient dc-link voltage so that the whole capacity of the grid side converter (GSC) is dedicated to injecting reactive power to the grid for the transient voltage support. However, the rotor-side converter (RSC) has different control tasks for different periods of the grid fault. Firstly, for Period I, the RSC injects the demagnetizing current to ensure the controllability of the rotor voltage. Then, since the dc stator flux degenerates rapidly in Period II, the required demagnetizing current is low in Period II and the RSC uses the spare capacity to additionally generate the reactive (priority) and active current so that the transient voltage capability is corroborated and the DFIG also positively responds to the system frequency dynamic at the earliest time. Finally, a small amount of demagnetizing current is provided after the fault clearance. Most of the RSC capacity is used to inject the active current to further support the frequency recovery of the system. Simulations are carried out on a simple power system with a wind farm. Comparisons with other commonly used control methods are performed to validate the proposed control method.
引用
收藏
页数:12
相关论文
共 38 条
[31]   Analysis of chaos in doubly fed induction generator and sliding mode control of chaos synchronization [J].
Yu Yang ;
Mi Zeng-Qiang ;
Liu Xing-Jie .
ACTA PHYSICA SINICA, 2011, 60 (07)
[32]   Application of SMES to Enhance the Dynamic Performance of DFIG During Voltage Sag and Swell [J].
Yunus, A. M. Shiddiq ;
Masoum, Mohammad A. S. ;
Abu-Siada, A. .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2012, 22 (04)
[33]   Optimal control of state-of-charge of superconducting magnetic energy storage for wind power system [J].
Zhang, Kun ;
Mao, Chengxiong ;
Lu, Jiming ;
Wang, Dan ;
Chen, Xun ;
Zhang, Junfeng .
IET RENEWABLE POWER GENERATION, 2014, 8 (01) :58-66
[34]   Dynamical investigation and parameter stability region analysis of a flywheel energy storage system in charging mode [J].
Zhang Wei-Ya ;
Li Yong-Li ;
Chang Xiao-Yong ;
Wang Nan .
CHINESE PHYSICS B, 2013, 22 (09)
[35]   Chaotic characteristics analysis and prediction model study on wind power time series [J].
Zhang Xue-Qing ;
Liang Jun .
ACTA PHYSICA SINICA, 2012, 61 (19)
[36]   Controlling chaos in power system based on finite-time stability theory [J].
Zhao Hui ;
Ma Ya-Jun ;
Liu Si-Jia ;
Gao Shi-Gen ;
Zhong Dan .
CHINESE PHYSICS B, 2011, 20 (12)
[37]   Adaptive backstepping control of chaotic property in direct-driveven permanent magnet sychronous generators for wind power [J].
Zheng Gang ;
Zou Jian-Xiao ;
Xu Hong-Bing ;
Qin Gang .
ACTA PHYSICA SINICA, 2011, 60 (06)
[38]   Dynamical analysis and experimental verification of valley current controlled buck converter [J].
Zhou Guo-Hua ;
Bao Bo-Cheng ;
Xu Jian-Ping ;
Jin Yan-Yan .
CHINESE PHYSICS B, 2010, 19 (05) :0505091-0505097