Structural Performance of a New Blind-Bolted Frame Modular Beam-Column Connection under Lateral Loading

被引:35
作者
Cho, Bong-Ho [1 ]
Lee, Jae-Sub [1 ]
Kim, Hongjin [2 ]
Kim, Dae-Jin [3 ]
机构
[1] Ajou Univ, Dept Architectural Engn, Suwon 16499, South Korea
[2] Kyungpook Natl Univ, Dept Architectural Engn, Daegu 41566, South Korea
[3] Kyung Hee Univ, Dept Architectural Engn, Yongin 17104, South Korea
来源
APPLIED SCIENCES-BASEL | 2019年 / 9卷 / 09期
基金
新加坡国家研究基金会;
关键词
steel modular building; beam-column connection; lateral loading; hysteresis curve; SEISMIC EXPERIMENT; STEEL; JOINT; PANEL;
D O I
10.3390/app9091929
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This study proposes an effective steel frame modular system and evaluates the structural performance of its beam-column connection through experimental and analytical work. The new steel frame modular system utilizes the blind bolts, which allow free access to the structural members of the closed cross-section. In addition, the new modular system is designed such that the strength of its beam members is considerably lower than that of its column members to implement the strong column-weak beam concept. In order to investigate the effectiveness of the proposed modular beam-column connection, two types of specimens were designed and tested. One of the two specimens has four knee brace members to increase the bending stiffness of the connection, while the other does not have these components. The applied load versus displacement curves are plotted for the two specimens, and their failure modes are identified. Finally, a simplified analytical model for the modular beam-column connection is proposed, and its effectiveness is validated by performing its push-over analysis and comparing its results with the test results.
引用
收藏
页数:21
相关论文
共 26 条
[1]  
American Institute of Steel Construction, 2010, MAN STEEL CONSTR LOA
[2]   Experimental evaluation of the seismic performance of modular steel-braced frames [J].
Annan, C. D. ;
Youssef, M. A. ;
El Naggar, M. H. .
ENGINEERING STRUCTURES, 2009, 31 (07) :1435-1446
[3]  
[Anonymous], 2012, ANN BOOK ASTM STAND
[4]   The practice of blind bolting connections to structural hollow sections: A review [J].
Barnett, T. C. ;
Tizani, W. ;
Nethercot, D. A. .
STEEL AND COMPOSITE STRUCTURES, 2001, 1 (01) :1-16
[5]  
Chao SH, 2008, ENG J AISC, V45, P127
[6]   Systematic approach to the design of modular military housing units using six-sigma [J].
Cho, B. -H. ;
Kim, D. -J. ;
Ha, T. .
SCIENTIA IRANICA, 2019, 26 (06) :3085-3096
[7]   Monotonic and cyclic response of bolted connections with welded cover plate for modular steel construction [J].
Deng, En-Feng ;
Zong, Liang ;
Ding, Yang ;
Dai, Xiao-Meng ;
Lon, Ni ;
Chen, Yang .
ENGINEERING STRUCTURES, 2018, 167 :407-419
[8]  
FIELDING DJ, 1971, WELD J, V50, pS313
[9]   Modular buildings in modern construction [J].
Generalova, Elena M. ;
Generalov, Viktor P. ;
Kuznetsova, Anna A. .
XXV POLISH - RUSSIAN - SLOVAK SEMINAR -THEORETICAL FOUNDATION OF CIVIL ENGINEERING, 2016, 153 :167-172
[10]  
Hisham S.B., 1995, ENG STRUCT, V17, P352