Impact of deep sedation on the accuracy of hepatic and portal venous pressure measurements in patients with cirrhosis

被引:70
作者
Reverter, Enric [1 ,2 ]
Blasi, Annabel [3 ]
Abraldes, Juan G. [1 ,2 ]
Martinez-Palli, Graciela [3 ]
Seijo, Susana [1 ,2 ]
Turon, Fanny [1 ,2 ]
Berzigotti, Annalisa [1 ,2 ]
Balust, Jaume [3 ]
Bosch, Jaume [1 ,2 ]
Garcia-Pagan, Juan C. [1 ,2 ]
机构
[1] Univ Barcelona, Hepat Hemodynam Lab, IDIBAPS Inst Invest Biomed August Pi i Sunyer, Liver Unit, E-08036 Barcelona, Spain
[2] CIBERehd Ctr Invest Biomed Red Enfermedades Hepat, Barcelona 08036, Spain
[3] Univ Barcelona, Dept Anesthesiol, IDIBAPS Inst Invest Biomed August Pi i Sunyer, Hosp Clin, E-08036 Barcelona, Spain
关键词
anaesthesia; portal hypertension; propofol; remifentanil; TIPS; INTRAHEPATIC PORTOSYSTEMIC SHUNT; ACUTE HEMODYNAMIC-RESPONSE; BLOOD-FLOW; PROTEIN-BINDING; PROPOFOL; PHARMACOKINETICS; REMIFENTANIL; HYPERTENSION; MANAGEMENT; MIDAZOLAM;
D O I
10.1111/liv.12229
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background & AimsMeasurement of the hepatic venous pressure gradient (HVPG) offers valuable prognostic information in patients with cirrhosis. In specific circumstances, (children, agitated patients, TIPS placement) deep sedation is required. This study aims to assess the impact of deep sedation on the accuracy of hepatic/portal pressure measurements. MethodsForty-four patients were included. Measurements of baseline HVPG (n=30), HVPG response to i.v. propranolol (n=11), portal pressure gradient (PPG) after TIPS (n=27) and of cardio-pulmonary pressures (n=25) were obtained in awake conditions and under deep sedation with propofol and remifentanil. ResultsDuring deep sedation, a marked oscillation within respiratory cycle was observed in abdominal pressures. End-expiratory sedated HVPG showed a better agreement with awake HVPG (intra-class correlation coefficient - ICC 0.864) than end-inspiratory HVPG (ICC 0.796). However, in almost half of the patients both values differed by more than 10%. Accuracy was not improved by using mean HVPG along the respiratory cycle. Similarly, changes in HVPG caused by propranolol while under sedation had a poor agreement to those obtained in awake conditions. Indeed, about a half of patients were misclassified according to the 10% HVPG reduction target. After TIPS, PPG values obtained under sedation were significantly different to awake PPG, usually underestimating the awake value. The systemic hemodynamic changes induced by sedation were not associated to a greater variability of PPG/HVPG measurements. ConclusionDeep sedation with propofol and remifentanil adds substantial variability and uncertainty to HVPG/PPG measurements. This must be considered when using these values to estimate prognosis, or targeting HVPG/PPG reductions.
引用
收藏
页码:16 / 25
页数:10
相关论文
共 45 条
  • [1] Hemodynamic response to pharmacological treatment of portal hypertension and long-term prognosis of cirrhosis
    Abraldes, JG
    Tarantino, I
    Turnes, J
    Garcia-Pagan, JC
    Rodés, J
    Bosch, J
    [J]. HEPATOLOGY, 2003, 37 (04) : 902 - 908
  • [2] Deep sedation with propofol does not precipitate hepatic encephalopathy during elective upper endoscopy
    Amoros, Amparo
    Aparicio, Jose R.
    Garmendia, Marta
    Casellas, Juan A.
    Martinez, Juan
    Jover, Rodrigo
    [J]. GASTROINTESTINAL ENDOSCOPY, 2009, 70 (02) : 262 - 268
  • [3] MEASURES OF AGREEMENT - A SINGLE PROCEDURE
    BARTKO, JJ
    [J]. STATISTICS IN MEDICINE, 1994, 13 (5-7) : 737 - 745
  • [4] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [5] Measurement of portal pressure and its role in the management of chronic liver disease
    Bosch, Jaime
    Garcia-Pagan, Juan Carlos
    Berzigotti, Annalisa
    Abraldes, Juan G.
    [J]. SEMINARS IN LIVER DISEASE, 2006, 26 (04) : 348 - 362
  • [6] The clinical use of HVPG measurements in chronic liver disease
    Bosch, Jaime
    Abraldes, Juan G.
    Berzigotti, Annalisa
    Carlos Garcia-Pagan, Juan
    [J]. NATURE REVIEWS GASTROENTEROLOGY & HEPATOLOGY, 2009, 6 (10) : 573 - 582
  • [7] The role of transjugular intrahepatic portosystemic shunt in the management of portal hypertension
    Boyer, TD
    Haskal, ZJ
    [J]. HEPATOLOGY, 2005, 41 (02) : 386 - 400
  • [8] Role of Transjugular Intrahepatic Portosystemic Shunt (TIPS) in the Management of Portal Hypertension: Update 2009
    Boyer, Thomas D.
    Haskal, Ziv J.
    [J]. HEPATOLOGY, 2010, 51 (01) : 306 - 306
  • [9] EFFECT OF PROPOFOL INFUSION ON SPLANCHNIC HEMODYNAMICS AND LIVER OXYGEN-CONSUMPTION IN THE RAT - A DOSE-RESPONSE STUDY
    CARMICHAEL, FJ
    CRAWFORD, MW
    KHAYYAM, N
    SALDIVIA, V
    [J]. ANESTHESIOLOGY, 1993, 79 (05) : 1051 - 1060
  • [10] Clinical events after transjugular intrahepatic portosystemic shunt:: Correlation with hemodynamic findings
    Casado, M
    Bosch, J
    García-Pagán, JC
    Bru, C
    Bañares, R
    Bandi, JC
    Escorsell, A
    Rodríguez-Láiz, JM
    Gilabert, R
    Feu, F
    Schorlemer, C
    Echenagusia, A
    Rodés, J
    [J]. GASTROENTEROLOGY, 1998, 114 (06) : 1296 - 1303