Review of external convective heat transfer coefficient models in building energy simulation programs: Implementation and uncertainty

被引:254
作者
Mirsadeghi, M. [1 ]
Costola, D. [1 ]
Blocken, B. [1 ]
Hensen, J. L. M. [1 ]
机构
[1] Eindhoven Univ Technol, NL-5600 MB Eindhoven, Netherlands
关键词
Convective heat transfer coefficient; Wind-induced heat transfer; Buoyancy; Heat; air and moisture transfer (HAM); Building envelope; WIND-DRIVEN RAIN; TEMPERATURE WALL FUNCTION; FULL-SCALE MEASUREMENTS; CFD SIMULATION; PERFORMANCE SIMULATION; BLUFF-BODIES; SURFACE; FLOW; ENVIRONMENT; FIELD;
D O I
10.1016/j.applthermaleng.2013.03.003
中图分类号
O414.1 [热力学];
学科分类号
摘要
Convective heat transfer coefficients for external building surfaces (h(c,ext)) are essential in building energy simulation (BES) to calculate convective heat gains and losses from building facades and roofs to the environment. These coefficients are complex functions of, among other factors, building geometry, building surroundings, building facade roughness, local air flow patterns and temperature differences. Previous research on h(c,ext) has led to a number of empirical models, many of which are implemented in BES programs. This paper first provides an extensive overview of such models for h(c,ext) calculation implemented in BES programs together with the corresponding assumptions. Next, the factors taken into account by each model are listed, in order to clarify model capabilities and deficiencies. Finally, the uncertainty related to the use of these models is discussed by means of a case study, where the use of different models shows deviations up to +/- 30% in the yearly cooling energy demand (in relation to the average result) and +/- 14% in the hourly peak cooling energy demand of an isolated, well-insulated building, while deviations in yearly heating energy demand are around +/- 6%. The paper concludes that each model has a specific range of application, which is identified in this review paper. It also concludes that there is considerable uncertainty in the prediction of h(c,ext), which can be transferred to the BES results. This large uncertainty highlights the importance of using an appropriate convection model for simulations of a specific building, certainly for calculating cooling demands and related important performance indicators such as indoor temperatures, indoor relatively humidity, thermal comfort, etc. (c) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:134 / 151
页数:18
相关论文
共 87 条
[11]  
[Anonymous], 2001, HDB FUNDAMENTALS
[12]  
[Anonymous], 1981, ASHRAE Handbook of Fundamentals
[13]  
[Anonymous], P CIB W67 3 INT S EN
[14]  
[Anonymous], ENERGYPLUS ENG REF R
[15]  
[Anonymous], SUNREL TECHNICAL REF
[16]  
[Anonymous], 1983, THERMAL ANAL RES PRO
[17]  
ASHRAE, 1975, PROC DET HEAT COOL L
[18]   Numerical Study on the Existence of the Venturi Effect in Passages between Perpendicular Buildings [J].
Blocken, B. ;
Moonen, P. ;
Stathopoulos, T. ;
Carmeliet, J. .
JOURNAL OF ENGINEERING MECHANICS, 2008, 134 (12) :1021-1028
[19]   The influence of the wind-blocking effect by a building on its wind-driven rain exposure [J].
Blocken, B ;
Carmeliet, J .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2006, 94 (02) :101-127
[20]   High-resolution wind-driven rain measurements on a low-rise building - experimental data for model development and model validation [J].
Blocken, B ;
Carmeliet, J .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2005, 93 (12) :905-928