Outcomes of Heavy Silicone Oil (Densiron) compared to Silicone Oil in primary rhegmatogenous retinal detachment: a multivariable regression model

被引:13
作者
Moussa, George [1 ,2 ,3 ]
Tadros, Maria [3 ]
Ch'ng, Soon Wai [3 ]
Sharma, Ash [3 ]
Lett, Kim Son [3 ]
Mitra, Arijit [3 ]
Tyagi, Ajai K. [3 ]
Andreatta, Walter [3 ,4 ,5 ]
机构
[1] Univ Birmingham, Birmingham & Midland Eye Ctr, Birmingham, W Midlands, England
[2] Univ Birmingham, Acad Unit Ophthalmol, Birmingham, W Midlands, England
[3] Birmingham Hosp NHS Trust, Birmingham & Midland Eye Ctr, Dudley Rd, Birmingham B18 7QH, W Midlands, England
[4] Kantonsspital Winterthur, Brauerstr 15, CH-8400 Winterthur, Switzerland
[5] Univ Zurich, Ramistr 71, CH-8006 Zurich, Switzerland
关键词
Retinal detachment; Silicone oil; Heavy oil; Heavy silicone oil; Densiron; Outcomes; Vitreoretinal; Retina; Glaucoma; Retinectomy; INTRAOCULAR-PRESSURE; TAMPONADE; ENDOTAMPONADE;
D O I
10.1186/s40942-022-00413-0
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To measure the visual outcomes, proliferative vitreoretinopathy (PVR) and retinectomy rates following primary rhegmatogenous retinal detachment (RRD) repair, comparing silicone oil (SO) and heavy SO (Densiron). Methods Retrospective, continuous comparative study from January 2017 to May 2021 of all primary RRD. Multivariable linear (logMAR gain) and binary-logistic (PVR-C and retinectomy rate) regression models to compare tamponade were performed. Covariates included age, gender, ocular co-morbidities, high myopia, macula-status, giant-retinal-tear (GRT), pre-op vision, PVR-C, oil type, perfluorocarbon-use, combined scleral buckle/vitrectomy, combined phaco-vitrectomy, 360-degrees-endolaser and oil duration. Cases with trauma or less than six-month follow-up were excluded. Results A total of 259 primary RD were analysed. There were 179 SO patients and 80 Densiron patients that had six-month primary re-detachment in 18 (10.1%) and 8 (10.0%) respectively (p = 1.000). No difference in logMAR gain was detected between tamponade choice on multivariable linear regression. Subsequent glaucoma surgery was 5 (2.8%) and 4 (5.0%) for SO and Densiron patients respectively (p = 0.464). On multivariate binary-logistic regression we found no difference in development of PVR-C between oil tamponades. However, SO had significantly higher subsequent retinectomy rate compared to Densiron (odds ratio 15.3, 95% CI 1.9-125.5, p = 0.011). Duration of oil tamponade was not linked to differences in logMAR gain, PVR-C formation or increased retinectomy rate. Conclusions We report no difference in primary anatomical success, number of further RRD surgeries, subsequent glaucoma surgery, visual outcomes, PVR-C between both tamponades on multivariable models. Densiron oil was found to be more retinectomy sparing relative to SO.
引用
收藏
页数:8
相关论文
共 14 条
[1]   Long-term outcomes of heavy silicone oil tamponade for complicated retinal detachment [J].
Berker, N. ;
Batman, C. ;
Ozdamar, Y. ;
Eranil, S. ;
Aslan, O. ;
Zilelioglu, O. .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2007, 17 (05) :797-803
[2]   Densiron 68 heavy silicone oil in the management of inferior retinal detachment recurrence: analysis on functional and anatomical outcomes and complications [J].
Caporossi, Tomaso ;
Franco, Fabrizio ;
Finocchio, Lucia ;
Barca, Francesco ;
Giansanti, Fabrizio ;
Tartaro, Ruggero ;
Virgili, Gianni ;
Rizzo, Stanislao .
INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2019, 12 (04) :615-620
[3]   The Royal College of Ophthalmologists' National Ophthalmology Database study of cataract surgery: report 1, visual outcomes and complications [J].
Day, A. C. ;
Donachie, P. H. J. ;
Sparrow, J. M. ;
Johnston, R. L. .
EYE, 2015, 29 (04) :552-560
[4]   Heavy tamponade 1: a review of indications, use, and complications [J].
Heimann, H. ;
Stappler, T. ;
Wong, D. .
EYE, 2008, 22 (10) :1342-1359
[5]   Anatomical and functional results of endotamponade with heavy silicone oil -: Densiron® 68 -: in complicated retinal detachment [J].
Herbrig, Erdmuth ;
Sandner, Dirk ;
Engelmann, Katrin .
OPHTHALMIC RESEARCH, 2007, 39 (04) :198-206
[6]   Clinicopathological correlation of epiretinal membranes and posterior lens opacification following perfluorohexyloctane tamponade [J].
Hiscott, P ;
Magee, RM ;
Colthurst, M ;
Lois, N ;
Wong, D .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (02) :179-183
[7]   Heavy silicone oil versus standard silicone oil in as vitreous tamponade in inferior PVR (HSO Study): interim analysis [J].
Joussen, Antonia M. ;
Rizzo, Stanislao ;
Kirchhof, Bernd ;
Schrage, Norbert ;
Li, Xiaoxin ;
Lente, Christina ;
Hilgers, Ralf-Dieter .
ACTA OPHTHALMOLOGICA, 2011, 89 (06) :E483-E489
[8]   Comparison of Densiron 68 and 1 000 cSt silicone oil in the management of rhegmatogenous retinal detachment with inferior breaks [J].
Kocak, Ibrahim ;
Koc, Haci .
INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2013, 6 (01) :81-84
[9]   Clinical complications of Densiron 68 intraocular tamponade for complicated retinal detachment [J].
Li, W. ;
Zheng, J. ;
Zheng, Q. ;
Wu, R. ;
Wang, X. ;
Xu, M. .
EYE, 2010, 24 (01) :21-28
[10]   A novel excel sheet conversion tool from Snellen fraction to LogMAR including 'counting fingers', 'hand movement', 'light perception' and 'no light perception' and focused review of literature of low visual acuity reference values [J].
Moussa, George ;
Bassilious, Kerolos ;
Mathews, Namita .
ACTA OPHTHALMOLOGICA, 2021, 99 (06) :E963-E965