Analysis of the Implementation of the Primary and/or Inertial Frequency Control in Variable Speed Wind Turbines in an Isolated Power System with High Renewable Penetration. Case Study: El Hierro Power System

被引:17
作者
Martinez-Lucas, Guillermo [1 ]
Ignacio Sarasua, Jose [1 ]
Ignacio Perez-Diaz, Juan [1 ]
Martinez, Sergio [2 ,3 ]
Ochoa, Danny [2 ,3 ]
机构
[1] Univ Politecn Madrid, Dept Hydraul Energy & Environm Engn, C Prof Aranguren 3, Madrid 28040, Spain
[2] Univ Politecn Madrid, Dept Automat, ETSI Ind, Elect Engn & Elect, C Jose Gutierrez Abascal 2, Madrid 28006, Spain
[3] Univ Politecn Madrid, ETSI Ind, Ind Informat, C Jose Gutierrez Abascal 2, Madrid 28006, Spain
关键词
isolated power system; frequency regulation; variable speed wind turbine; primary frequency regulation; inertia emulation; STORAGE-SYSTEMS; ENERGY; PLANTS; ISLAND; GENERATION; FARM;
D O I
10.3390/electronics9060901
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
With high levels of wind energy penetration, the frequency response of isolated power systems is more likely to be affected in the event of a sudden frequency disturbance or fluctuating wind conditions. In order to minimize excessive frequency deviations, several techniques and control strategies involving Variable Speed Wind Turbines (VSWTs) have been investigated in isolated power systems. In this paper, the main benefits and disadvantages of introducing VSWTs-both their inertial contribution and primary frequency regulation-in an exclusively renewable isolated power system have been analyzed. Special attention has been paid to the influence of the delays of control signals in the wind farm when VSWTs provide primary regulation as well as to the wind power reserve value which is needed. To achieve this objective, a methodology has been proposed and applied to a case study: El Hierro power system. A mathematical dynamic model of the isolated power system, including exclusively renewable technologies, has been described. Representative generation schedules and wind speed signals have been fixed according to the observed system. Finally, in order to obtain conclusions, realistic system events such as fluctuations in wind speed and the outage of the generation unit with the higher assigned power in the power system have been simulated.
引用
收藏
页数:24
相关论文
共 45 条
[1]   Overview of wind power intermittency impacts on power systems [J].
Albadi, M. H. ;
El-Saadany, E. F. .
ELECTRIC POWER SYSTEMS RESEARCH, 2010, 80 (06) :627-632
[2]  
[Anonymous], MODELING GE WIND TUR
[3]  
[Anonymous], ROLE ENERGY STORAGE
[4]   A review on frequency support provision by wind power plants: Current and future challenges [J].
Attya, A. B. ;
Dominguez-Garcia, J. L. ;
Anaya-Lara, O. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2018, 81 :2071-2087
[5]   Frequency regulation capabilities in wind power plant [J].
Aziz, Asma ;
Oo, Aman Than ;
Stojcevski, Alex .
SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2018, 26 :47-76
[6]   Wind powered pumped hydro storage systems, a means of increasing the penetration of renewable energy in the Canary Islands [J].
Bueno, C. ;
Carta, J. A. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2006, 10 (04) :312-340
[7]   Analysis of the combined use of wind and pumped storage systems in autonomous Greek islands [J].
Caralis, G. ;
Zervos, A. .
IET RENEWABLE POWER GENERATION, 2007, 1 (01) :49-60
[8]   Variable Speed Wind Generators Participation in Primary Frequency Control [J].
Courtecuissea, Vincent ;
Robynsa, Benoit ;
Francoisb, Bruno ;
Petitc, Marc ;
Deused, Jacques .
WIND ENGINEERING, 2008, 32 (03) :299-318
[9]   Optimum generation control in wind parks when carrying out system operator requests [J].
de Almeida, RG ;
Castronuovo, ED ;
Lopes, JAP .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2006, 21 (02) :718-725
[10]  
De Espana R.E., 2019, B OF DEL ESTADO, V20, P137787