The Efficiency of Titanium Middle Ear Prosthesis in Ossicular Chain Reconstruction: Our Experience

被引:14
作者
Shah, Kshitij Dhaval [1 ]
Bradoo, Renuka A. [2 ]
Joshi, Anagha A. [2 ]
Sapkale, Deepti D. [2 ]
机构
[1] LTM Med Coll & Gen Hosp, Dept ENT, Monisha Cooperat Housing Soc, Bombay 400058, Maharashtra, India
[2] LTM Med Coll & Gen Hosp, Dept ENT, Bombay 400058, Maharashtra, India
关键词
Ossicular reconstruction; Titanium middle ear prosthesis; PORP; TORP; OSSICULOPLASTY; IMPLANTS; REPLACEMENT;
D O I
10.1007/s12070-011-0373-9
中图分类号
R61 [外科手术学];
学科分类号
摘要
Middle ear ossicular reconstruction is a challenging task for any otologist. Over a period of time, surgeons have tried various types of materials as ossicular prosthesis with varying amount of success. In the last decade, numerous studies have been conducted that have proved that titanium prosthesis is biocompatible. We have conducted this study to investigate the efficiency of titanium middle ear prosthesis (Eon Meditech Pvt. Ltd.) in tympanoplasty. Nineteen patients who underwent tympanoplasty with titanium prosthesis placement from January to October 2010 were included in the study. Fifteen patients underwent reconstruction using titanium PORP while four patients required titanium TORP. The average follow up period was 11.1 months. The pre-operative and post-operative PTAs and the closure of the air-bone gap (ABG) at 0.5, 1, 2, 3 KHz (as per the AAO-HNS guidelines) were analyzed. As per the Indian speech and hearing association (ISHA) guidelines, the patients were classified into groups based on the amount of hearing loss. The improvement in the mean PTA (AC) was 16.21 dB in the PORP group while it was 20.47 dB in the TORP group (P value < 0.05). According to ISHA guidelines, 18 out of 19 (94.8%) patients had either a normal hearing or a mild hearing loss post-operatively. The overall success rate (post-operative ABG <= 20 dB) of this series is 68.4%. In this series, there has been no extrusion of the prosthesis. Titanium prosthesis is delicate, easy and quick to handle. They are efficient and suitable implants for middle ear ossicular reconstruction. The use of cartilage between the prosthesis and the graft helps to prevent extrusion of the prosthesis.
引用
收藏
页码:298 / 301
页数:4
相关论文
共 36 条
  • [31] Titanium prosthesis or autologous incus for total ossicular reconstruction in the absence of the stapes suprastructure and presence of mobile footplate
    Abdulmajeed Zakzouk
    Nicolas Bonmardion
    Pierre Bouchetemble
    Yannick Lerosey
    Jean-Paul Marie
    European Archives of Oto-Rhino-Laryngology, 2015, 272 : 2653 - 2657
  • [32] Titanium implants for the reconstruction of the ossicular chain (results from a multi-centred study).
    Begall, K
    Zimmermann, H
    LARYNGO-RHINO-OTOLOGIE, 2000, 79 (03) : 139 - +
  • [33] Titanium prosthesis or autologous incus for total ossicular reconstruction in the absence of the stapes suprastructure and presence of mobile footplate
    Zakzouk, Abdulmajeed
    Bonmardion, Nicolas
    Bouchetemble, Pierre
    Lerosey, Yannick
    Marie, Jean-Paul
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2015, 272 (10) : 2653 - 2657
  • [34] A Modified Prosthesis Head for Middle Ear Titanium Implants-Experimental and First Clinical Results
    Luers, Jan Christoffer
    Huttenbrink, Karl-Bernd
    Mickenhagen, Axel
    Beutner, Dirk
    OTOLOGY & NEUROTOLOGY, 2010, 31 (04) : 624 - 629
  • [35] Titanium ossicular chain reconstruction in single stage canal wall down tympanoplasty for chronic otitis media with mucosa defect
    Gu, Feng-Ming
    Chi, Fang-Lu
    AMERICAN JOURNAL OF OTOLARYNGOLOGY, 2019, 40 (02) : 205 - 208
  • [36] Outcomes following ossicular chain reconstruction with composite prostheses: Hydroxyapatite-polyethylene vs. hydroxyapatite-titanium
    Hahn, Yoav
    Bojrab, Dennis I.
    ENT-EAR NOSE & THROAT JOURNAL, 2013, 92 (06) : 250 - +