Comparison of Information-Dependent Acquisition, SWATH, and MSAll Techniques in Metabolite Identification Study Employing Ultrahigh-Performance Liquid Chromatography-Quadrupole Time-of-Flight Mass Spectrometry

被引:175
作者
Zhu, Xiaochun [1 ]
Chen, Yuping [1 ]
Subramanian, Raju [1 ]
机构
[1] Amgen Inc, Pharmacokinet & Drug Metab, Thousand Oaks, CA 91320 USA
关键词
HIGH-RESOLUTION MS; IN-VITRO; DRUG METABOLITES; HIGH-THROUGHPUT; TOF MS; DISCOVERY;
D O I
10.1021/ac403385y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Sensitive and selective liquid chromatography-mass spectrometry. (LC-MS) analysis is a powerful and essential tool for metabolite identification in drug discovery and development. An MS2 (or tandem, MS/MS) mass spectrum is acquired from the fragmentation of a precursor ion by multiple methods including information-dependent acquisition (IDA), SWATH (sequential window acquisition of all theoretical fragment-ion spectra), and MSAll (also called MSE) techniques. We compared these three techniques in their capabilities to produce comprehensive MS2 data by assessing both metabolite MS2 acquisition hit rate and the quality of MS2 spectra. Rat liver microsomal incubations from eight test compounds were analyzed with four methods (IDA, MMDF (multiple mass defect filters)-IDA, SWATH, or MSA(ll)) using an ultrahigh-performance liquid chromatography-qudrupole time-of-flight mass spectrometry (UHPLC-Q-TOF MS) platform. A combined total of 227 drug-related materials (DRM) were detected from all eight test article incubations, and among those, 5% and 4% of DRM were not triggered for MS2 acquisition with IDA and MMDF-IDA methods, respectively. When the same samples were spiked to an equal volume of blank rat urine (urine sample), the DRM without MS2 acquisition increased to 29% and 18%, correspondingly. In contrast, 100% of DRM in both matrixes were subjected to MS2 acquisition with either the SWATH or MSAll method. However, the quality of the acquired MS2 spectra decreased in the order of IDA, SWATH, and MSAll methods. An average of 10, 9, and 6 out of 10 most abundant ions in MS2 spectra were the real product ions of DRM detected in microsomal samples from IDA, SWATH, and MSAll methods, respectively. The corresponding numbers declined to 9, 6, and 3 in the urine samples. Overall, IDA-based methods acquired qualitatively better MS2 spectra but with a lower MS2 acquisition hit rate than the other two methods. SWATH outperformed the MSAll method given its better quality of MS2 spectra with an identical MS2 acquisition hit rate.
引用
收藏
页码:1202 / 1209
页数:8
相关论文
共 35 条
  • [1] Performance Characteristics of a New Hybrid Quadrupole Time-of-Flight Tandem Mass Spectrometer (TripleTOF 5600)
    Andrews, Genna L.
    Simons, Brigitte L.
    Young, J. Bryce
    Hawkridge, Adam M.
    Muddiman, David C.
    [J]. ANALYTICAL CHEMISTRY, 2011, 83 (13) : 5442 - 5446
  • [2] [Anonymous], 2008, GUID IND SAF TEST DR
  • [3] Mass spectrometry for translational proteomics: progress and clinical implications
    Baker, Erin Shammel
    Liu, Tao
    Petyuk, Vladislav A.
    Burnum-Johnson, Kristin E.
    Ibrahim, Yehia M.
    Anderson, Gordon A.
    Smith, Richard D.
    [J]. GENOME MEDICINE, 2012, 4
  • [4] MSE with mass defect filtering for in vitro and in vivo metabolite identification
    Bateman, Kevin P.
    Castro-Perez, Jose
    Wrona, Mark
    Shockcor, John P.
    Yu, Kate
    Oballa, Renata
    Nicoll-Griffith, Deborah A.
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (09) : 1485 - 1496
  • [5] A novel precursor ion discovery method on a hybrid quadrupole orthogonal acceleration time-of-flight (Q-TOF) mass spectrometer for studying protein phosphorylation
    Bateman, RH
    Carruthers, R
    Hoyes, JB
    Jones, C
    Langridge, JI
    Millar, A
    Vissers, JPC
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2002, 13 (07) : 792 - 803
  • [6] Resolving the microcosmos of complex samples: UPLC/travelling wave ion mobility separation high resolution mass spectrometry for the analysis of in vivo drug metabolism studies
    Blech, Stefan
    Laux, Ralf
    [J]. INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2013, 16 (01) : 5 - 17
  • [7] Increasing throughput and information content for in vitro drug metabolism experiments using ultra-performance liquid chromatography coupled to a quadrupole time-of-flight mass spectrometer
    Castro-Perez, J
    Plumb, R
    Granger, JH
    Beattie, L
    Joncour, K
    Wright, A
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (06) : 843 - 848
  • [8] A high-throughput liquid chromatography/tandem mass spectrometry method for screening glutathione conjugates using exact mass neutral loss acquisition
    Castro-Perez, J
    Plumb, R
    Liang, L
    Yang, E
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (06) : 798 - 804
  • [9] An introduction to quadrupole-time-of-flight mass spectrometry
    Chernushevich, IV
    Loboda, AV
    Thomson, BA
    [J]. JOURNAL OF MASS SPECTROMETRY, 2001, 36 (08): : 849 - 865
  • [10] Information-dependent acquisition-mediated LC-MS/MS screening procedure with semiquantitative potential
    Decaestecker, TN
    Casteele, SRV
    Wallemacq, PE
    Van Peteghem, CH
    Defore, DL
    Van Bocxlaer, JF
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (21) : 6365 - 6373