Effects of Different Implant Osteotomy Preparation Sizes on Implant Stability and Bone Response in the Minipig Mandible

被引:27
|
作者
Eom, Tae-Gwan [1 ,2 ]
Kim, Hyo-won [1 ]
Jeon, Gyeo-Rok [2 ]
Yun, Mi-Jung [3 ]
Huh, Jung-Bo [3 ]
Jeong, Chang-Mo [3 ]
机构
[1] OSSTEM IMPLANT Co Ltd, Implant R&D Ctr, Busan, South Korea
[2] Pusan Natl Univ, Sch Med, Dept Biomed Engn, Busan, South Korea
[3] Pusan Natl Univ, Sch Dent, Dent Res Inst, Dept Prosthodont, Busan, South Korea
关键词
bone response; dental implant; implant stability; osteotomy preparation size; RESONANCE FREQUENCY MEASUREMENTS; DENTAL IMPLANTS; TITANIUM IMPLANTS; INSERTION TORQUE; TISSUE-REACTIONS; HEAT-GENERATION; MINIATURE PIGS; IN-VIVO; PLACEMENT; MAXILLA;
D O I
10.11607/jomi.4165
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this study was to investigate the influence of implant and drill diameters on the stability of implant and bone response. Materials and Methods: An implant (GS II, Osstem Implant) with a 3.5-mm diameter and drills with three different diameters, differentiating the volume of bone compacted by the implant, were used in this study. Measurement of the insertion torque and observation of bone compression patterns were done during implant site preparation in minipigs. Also, analysis of resonance frequency, histomorphology, marginal bone resorption, and new bone formation were performed. Results: Microstrains and microcracks occurred in cortical bone around the thread when a drill with a smaller diameter than that of the thread was used. Higher implant stability was shown and maintained when a small-diameter drill was used. When using a drill with a smaller diameter than the root diameter of the implant thread, the bone-to-implant contact/bone area (BIC/BA) was higher than the wider drill during the whole test period. However, the use of a wide drill was the most rapid in increasing the BIC/BA value by new bone formation. In the cancellous bone, the speed of new bone formation was not different in each test group. However, the formation of new bone was faster when a large-diameter drill was used in the cortical bone. There was no significant difference in marginal bone loss (MBL) according to drill diameters, but the speed of MBL was fast when using a drill that was smaller than the root diameter of the implant thread. Conclusion: Implant stability, BIC, and BA were high when using a final drill that was smaller than the root diameter of the implant thread compared with a wide final drill. However, the speed of new bone formation was relatively slow and the speed of MBL was relatively fast if the final drill was excessively smaller.
引用
收藏
页码:997 / 1006
页数:10
相关论文
共 50 条
  • [1] Effects of Osteotomy Lengths on the Temperature Rise of the Crestal Bone During Implant Site Preparation
    Katic, Zvonimir
    Jukic, Tomislav
    Stubljar, David
    IMPLANT DENTISTRY, 2018, 27 (02) : 213 - 220
  • [2] Effects on Ridge Dimensions, Bone Density, and Implant Primary Stability with Osseodensification Approach in Implant Osteotomy Preparation
    Yeh, Yu-Ting
    Chu, Tien-Min G.
    Blanchard, Steven B.
    Hamada, Yusuke
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (03) : 474 - 484
  • [3] A Novel Osseous Densification Approach in Implant Osteotomy Preparation to Increase Biomechanical Primary Stability, Bone Mineral Density, and Bone-to-Implant Contact
    Huwais, Salah
    Meyer, Eric G.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (01) : 27 - 36
  • [4] Effect of Implant Surface Properties on Peri-Implant Bone Healing: Implant Stability and Microcomputed Tomographic Analysis
    Al-Moaber, Samar H.
    Al-Hamdan, Khalid
    Junker, Rudiger
    Jansen, John A.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (01) : 77 - 83
  • [5] The Evaluation of Different Osteotomy Drilling Speed Protocols on Cortical Bone Temperature, Implant Stability and Bone Healing: An Experimental Study in an Animal Model
    Ozcan, Mustafa
    Salimov, Fariz
    Temmerman, Andy
    Turer, Onur Ucak
    Alkaya, Bahar
    Haytac, Mehmet Cenk
    JOURNAL OF ORAL IMPLANTOLOGY, 2022, 48 (01) : 3 - 8
  • [6] Relationship between the CT Value and Cortical Bone Thickness at Implant Recipient Sites and Primary Implant Stability with Comparison of Different Implant Types
    Howashi, Miori
    Tsukiyama, Yoshihiro
    Ayukawa, Yasunori
    Isoda-Akizuki, Kei
    Kihara, Masafumi
    Imai, Yu
    Sogo, Motofumi
    Koyano, Kiyoshi
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2016, 18 (01) : 107 - 116
  • [7] Implant Stability Quotients of Osteotome Bone Expansion and Conventional Drilling Technique for 4.1 mm Diameter Implant at Posterior Mandible
    Hong, Hsiang-Hsi
    Hong, Adrienne
    Yang, Lan-Yan
    Chang, Wei-Yang
    Huang, Yi-Fang
    Lin, Yen-Ting
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2017, 19 (02) : 253 - 260
  • [8] Effect of a macroscopic groove on bone response and implant stability
    Yoon, Hyung-In
    Yeo, In-Sung
    Yang, Jae-Ho
    CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (12) : 1379 - 1385
  • [9] Effects on primary stability of three different techniques for implant site preparation in synthetic bone models of different densities
    Moehlhenrich, S. C.
    Kniha, K.
    Heussen, N.
    Hoelzle, F.
    Modabber, A.
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2016, 54 (09) : 980 - 986
  • [10] Influence of Implant Design and Under-Preparation of the Implant Site on Implant Primary Stability. An In Vitro Study
    Herrero-Climent, Mariano
    Lemos, Bernardo Ferreira
    Herrero-Climent, Federico
    Falcao, Carlos
    Oliveira, Helder
    Herrera, Manuela
    Javier Gil, Francisco
    Rios-Carrasco, Blanca
    Rios-Santos, Jose-Vicente
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (12) : 1 - 13