Clinical and radiological outcome of percutaneous plating in extra-articular proximal tibia fractures: A prospective study

被引:26
作者
Naik, Monappa A. [1 ]
Arora, Gaurav [1 ]
Tripathy, Sujit Kumar [1 ]
Sujir, Premjit [1 ]
Rao, Sharath K. [1 ]
机构
[1] KMC, Dept Orthopaed, Manipal 576104, Karnataka, India
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2013年 / 44卷 / 08期
关键词
Proximal tibia fracture; Locking plate; Percutaneous fixation; Minimally invasive procedure; LCP; INTRAMEDULLARY NAILS; INTERNAL-FIXATION; STABILITY; STABILIZATION;
D O I
10.1016/j.injury.2013.03.002
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Despite various techniques of fixation, proximal tibia fractures are associated with poor outcome and increased rates of complications. Minimal access and rigid fixation are the keys for optimal outcome in such fractures. Therefore, this study was designed to look for the clinical and radiological outcomes of percutaneous locked plating (PLP) in extra-articular proximal tibia fracture. Methods: Between April 2008 and September 2010, 47 consecutive patients with 49 proximal third extra-articular tibial fractures (29 closed and 20 open injuries) underwent PLP. The patients were followed up at 6 weeks, 3 months, 6 months and 1 year. The union rate and complications of this fixation were evaluated. The clinico-radiological outcomes were assessed at 1 year of surgery. Results: Four patients had infection in the postoperative period which needed repeated debridement, gentamycin bead application and prolonged antibiotic therapy. Three of these infective cases ended up with nonunion and needed cancellous bone grafting. All the remaining fractures united. The average time for union was 20 weeks in closed and type I open fracture and 25 weeks in type II and III fractures. No neurovascular injury, hardware failure or loss of fixation was documented till the last follow-up. The mean range of knee joint movement was 119 degrees. The average lower extremity functional score (LEFS) was 59 (74%). There were 10 cases of malunion (20.14%), with six varus/valgus and five procurvatum/recurvatum (one having both sagittal and coronal malunion) angulations. There were no statistical differences between patients with malunion and normal alignment with regard to knee range of motion and LEFS. Conclusion: Minimally invasive osteosynthesis using PLP in extra-articular proximal tibia fractures showed a promising result with minimal complications. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1081 / 1086
页数:6
相关论文
共 50 条
[41]   Biomechanical Evaluation of a Modified Dorsal Double-plating Fixation with Adjustable Joint and Microthread Designs for Comminuted Extra-articular Distal Radius Fractures [J].
Lin, Yu-Hao ;
Chen, Alvin Chao-Yu ;
Kuo, Hsien-Nan ;
Yu, Tsung-Chih ;
Sun, Ming-Tsung ;
Lin, Chun-Li .
JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2013, 33 (01) :29-34
[42]   EVALUATION OF LOCKING COMPRESSION PLATING BY MIPPO TECHNIQUE IN PROXIMAL TIBIAL FRACTURES: A PROSPECTIVE STUDY [J].
Sujai, S. ;
Jayakrishnan, S. ;
Lokesh, B., V ;
Siddalingaswamy, M. K. ;
Nanjundappa, H. C. .
JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (54) :9492-9499
[43]   Does cement augmentation of the screws in angular stable plating for proximal humerus fractures influence the radiological outcome: a retrospective assessment [J].
Knierzinger, Dominik ;
Crepaz-Eger, Ulrich ;
Hengg, Clemens ;
Kralinger, Franz .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (10) :1413-1421
[44]   Should unstable extra-articular distal radial fractures be treated with fixed-angle volar-locked plates or percutaneous Kirschner wires? A prospective randomised controlled trial [J].
McFadyen, I. ;
Field, J. ;
McCann, P. ;
Ward, J. ;
Nicol, S. ;
Curwen, C. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2011, 42 (02) :162-166
[45]   Comparative study between volar locked plates versus closed reduction with percutaneous pinning in management of unstable extra-articular distal radius fractures [J].
Al-Shahwanii, Zaid Wajeh ;
Qaryaqos, Saher Habeeb .
JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2021, 71 (12) :S35-S39
[46]   An extra-articular procedure improves the clinical outcome in anterior cruciate ligament reconstruction with hamstrings in female athletes [J].
Vadala, Antonio Pasquale ;
Iorio, Raffaele ;
De Carli, Angelo ;
Bonifazi, Alberto ;
Iorio, Carlo ;
Gatti, Andrea ;
Rossi, Cristina ;
Ferretti, Andrea .
INTERNATIONAL ORTHOPAEDICS, 2013, 37 (02) :187-192
[47]   Volar Locking Plating of Extra-articular Distal Radius Fracture: A Retrospective Clinical Study Comparing Locking Screws versus Smooth Locking Pegs [J].
Tordjman, Daniel ;
Younis, Mohammad ;
Factor, Shai ;
Eisenberg, Gilad ;
Atlan, Franck ;
McBeth, Jessica ;
Pritsch, Tamir ;
Rosenblatt, Yishai .
JOURNAL OF WRIST SURGERY, 2024, 13 (02) :151-157
[48]   Fixation of Extra-Articular Distal Humerus Fractures Using One Locking Plate Versus Two Reconstruction Plates: A Laboratory Study [J].
Tejwani, Nirmal C. ;
Murthy, Anjali ;
Park, Jason ;
McLaurin, Toni M. ;
Egol, Kenneth A. ;
Kummer, Fred J. .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2009, 66 (03) :795-799
[49]   Multidirectional volar fixed-angle plating using cancellous locking screws for distal radius fractures - Evaluation of three screw configurations in an extra-articular fracture model [J].
Weninger, Patrick ;
Dall'Ara, Enrico ;
Drobetz, Herwig ;
Nemec, Wolfgang ;
Figl, Markus ;
Redl, Heinz ;
Hertz, Harald ;
Zysset, Philippe .
WIENER KLINISCHE WOCHENSCHRIFT, 2011, 123 (1-2) :4-10
[50]   Comparative analysis of Kirschner wire configurations for fixation of extra-articular proximal hallux fractures: Insights from synthetic composite bone models [J].
Kocak, Soner ;
Kilic, Bulent ;
Caliskan, Mustafa ;
Afacan, Muhammed Yusuf ;
Uzun, Bora ;
Ertem, Fatih ;
Gulabi, Deniz ;
Erturk, Cemil .
JOURNAL OF ORTHOPAEDIC SURGERY, 2024, 32 (03)