A solid phase microextraction coating based on ionic liquid sol-gel technique for determination of benzene, toluene, ethylbenzene and o-xylene in water samples using gas chromatography flame ionization detector

被引:55
作者
Sarafraz-Yazdi, Ali [1 ]
Vatani, Hossein [1 ]
机构
[1] Ferdowsi Univ Mashhad, Dept Chem, Fac Sci, Mashhad, Iran
关键词
Solid-phase microextraction; Ionic liquid; Sol-gel technique; Gas chromatography; BTEX; VOLATILE ORGANIC-COMPOUNDS; MASS-SPECTROMETRY; MESOPOROUS SILICA; CARBON NANOTUBES; SOIL SAMPLES; FIBERS; EXTRACTION; PERFORMANCE; SEPARATION; SOLVENT;
D O I
10.1016/j.chroma.2013.03.039
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Ionic liquid mediated sol-gel sorbents for head-space solid phase microextraction (HS-SPME) were developed for the extraction of benzene, toluene, ethylbenzene and o-xylene (BTEX) compounds from water samples in ultra-trace levels. The analytes were subsequently analyzed with gas chromatography coupled to flame ionization detector (GC-FID). Three different coating fibers were prepared including: poly(dimethylsiloxane) (PDMS), coating prepared from poly(dimethylsiloxane) in the presence of ionic liquid as co-solvent and conditioned at a higher temperature than decomposition temperature of ionic liquid (PDMS-IL-HT) and coating prepared from poly(dimethylsiloxane) in the presence of ionic liquid as co-solvent and conditioned at a lower temperature than decomposition temperature of ionic liquid (PDMS-IL-LT). Prepared fibers demonstrate many advantages such as high thermal and chemical stabilities due to the chemical bonding of the coatings with the silanol groups on the fused-silica surface fiber. These fibers have shown long life time up to 180 extractions. The scanning electron micrographs of the fibers surfaces revealed that addition of ionic liquid into the sol solution during the sol-gel process increases the fiber coating thickness, affects the form of fiber structure and also leaves high pores in the fiber surface that cause high surface area and therefore increases sample capacity of the fibers. The important parameters that affect the extraction efficiency are desorption temperature and time, sample volume, extraction temperature, extraction time, stirring speed and salt effect. Therefore these factors were investigated and optimized. Under optimal conditions, the dynamic linear range with PDMS-IL-HT, PDMS and PDMS-IL-LT fibers were 0.3-200,000; 50-200,000 and 170-150,000 pg mL(-1) and the detection limits (S/N = 3) were 0.1-2 and 15-200 and 50-500 pg mL(-1), and limit of quantifications (S/N = 10) were 0.3-8 and 50-700 and 170-1800, respectively. The relative standard deviations (RSD) for one fiber (repeatability) (n = 5), were obtained from 3.1 up to 5.4% and between fibers or batch to batch (reproducibility) (n = 3) in the range of 3.8-8.5% for three fibers. The developed method was successfully applied to the real water samples while the relative recovery percentages obtained for the spiked water samples at 20 pg mL(-1) were from 91.2 to 103.3%. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:104 / 111
页数:8
相关论文
共 46 条
[31]   A novel solid-phase microextraction using coated fiber based sol-gel technique using poly(ethylene glycol) grafted multi-walled carbon nanotubes for determination of benzene, toluene, ethylbenzene and o-xylene in water samples with gas chromatography-flam ionization detector [J].
Sarafraz-Yazdi, Ali ;
Amiri, Amirhassan ;
Rounaghi, Gholamhossein ;
Hosseini, Hossein Eshtiagh .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (34) :5757-5764
[32]   Comparative study of the three sol-gel based solid phase microextraction fibers in extraction of BTEX from water samples using gas chromatography-flame ionization detection [J].
Sarafraz-Yazdi, Ali ;
Moghadam, Hamed Piri ;
Es'haghi, Zarrin ;
Sepehr, Soroosh .
ANALYTICAL METHODS, 2010, 2 (06) :746-752
[33]   Ionic liquid-mediated bis[(3-methyldimethoxysilyl)propyl] polypropylene oxide-based polar sol-gel coatings for capillary microextraction [J].
Shearrow, Anne M. ;
Bhansali, Shekhar ;
Malik, Abdul .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (36) :6349-6355
[34]   Ionic liquid-mediated sol-gel coatings for capillary microextraction [J].
Shearrow, Anne M. ;
Harris, Glenn A. ;
Fang, Li ;
Sekhar, Praveen K. ;
Nguyen, Ly T. ;
Turner, Erica B. ;
Bhansali, Shekhar ;
Malik, Abdul .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (29) :5449-5458
[35]   Cross-linked polymer-ionic liquid composite materials [J].
Snedden, P ;
Cooper, AI ;
Scott, K ;
Winterton, N .
MACROMOLECULES, 2003, 36 (12) :4549-4556
[36]   Sensitive determination of free benzophenone-3 in human urine samples based on an ionic liquid as extractant phase in single-drop microextraction prior to liquid chromatography analysis [J].
Vidal, Lorena ;
Chisvert, Alberto ;
Canals, Antonio ;
Salvador, Amparo .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1174 (1-2) :95-103
[37]   Ionic liquid-modified materials for solid-phase extraction and separation: A review [J].
Vidal, Lorena ;
Riekkola, Marja-Liisa ;
Canals, Antonio .
ANALYTICA CHIMICA ACTA, 2012, 715 :19-41
[38]   EXPOSURES TO BENZENE AND OTHER VOLATILE COMPOUNDS FROM ACTIVE AND PASSIVE SMOKING [J].
WALLACE, L ;
PELLIZZARI, E ;
HARTWELL, TD ;
PERRITT, R ;
ZIEGENFUS, R .
ARCHIVES OF ENVIRONMENTAL HEALTH, 1987, 42 (05) :272-279
[39]   MAJOR SOURCES OF BENZENE EXPOSURE [J].
WALLACE, LA .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1989, 82 :165-169
[40]   Fabrication of molecularly imprinted hybrid monoliths via a room temperature ionic liquid-mediated nonhydrolytic sol-gel route for chiral separation of zolmitriptan by capillary electrochromatography [J].
Wang, He-Fang ;
Zhu, Yi-Zhou ;
Lin, Jian-Ping ;
Yan, Xiu-Ping .
ELECTROPHORESIS, 2008, 29 (04) :952-959